The development of new digital mammography techniques such as dual-energy imaging, tomosynthesis and CT breast imaging will require investigation of optimal camera design parameters and optimal imaging acquisition parameters. In optimizing these acquisition protocols and imaging systems it is important to have knowledge of the radiation dose to the breast. This study presents a methodology for estimating the normalized glandular dose to the uncompressed breast using the geometry proposed for flat-panel CT breast imaging. The simulation uses the GEANT 3 Monte Carlo code to model x-ray transport and absorption within the breast phantom. The Monte Carlo software was validated for breast dosimetry by comparing results of the normalized glandular dose (DgN) values of the compressed breast to those reported in the literature. The normalized glandular dose was then estimated for a range of breast diameters from 10 cm to 18 cm using an uncompressed breast model with a homogeneous composition of adipose and glandular tissue, and for monoenergetic x-rays from 10 keV to 120 keV. These data were fit providing expressions for the normalized glandular dose. Using these expressions for the DgN coefficients and input variables such as the diameter, height and composition of the breast phantom, the mean glandular dose for any spectra can be estimated. A computer program to provide normalized glandular dose values has been made available online. In addition, figures displaying energy deposition maps are presented to better understand the spatial distribution of dose in CT breast imaging.
[1]
Biao Chen,et al.
Cone-beam volume CT breast imaging: feasibility study.
,
2002,
Medical physics.
[2]
Srinivasan Vedantham,et al.
Investigation of optimal kVp settings for CT mammography using a flat-panel imager
,
2002,
SPIE Medical Imaging.
[3]
J. S. Laughlin,et al.
Absorbed radiation dose in mammography.
,
1979,
Radiology.
[4]
J. Boone,et al.
Glandular breast dose for monoenergetic and high-energy X-ray beams: Monte Carlo assessment.
,
1999,
Radiology.
[5]
T R Nelson,et al.
A comprehensive analysis of DgN(CT) coefficients for pendant-geometry cone-beam breast computed tomography.
,
2004,
Medical physics.
[6]
Ehsan Samei,et al.
Measurements of an optimized beam for x-ray computed mammotomography
,
2004,
SPIE Medical Imaging.
[7]
J. Boone.
Normalized glandular dose (DgN) coefficients for arbitrary X-ray spectra in mammography: computer-fit values of Monte Carlo derived data.
,
2002,
Medical physics.
[8]
J. Boone,et al.
Dedicated breast CT: radiation dose and image quality evaluation.
,
2001,
Radiology.