Electrochemical oxidation of p-nitrophenol using graphene-modified electrodes, and a comparison to the performance of MWNT-based electrodes

AbstractThe electrochemical oxidation of p-nitrophenol (p-NP) has been studied comparatively on a graphene modified electrode and a multiwall carbon nanotube (MWNT) electrode by using cyclic and differential pulse voltammetry. The sensors were fabricated by modifying screen-printed electrodes with graphene and MWNT nanomaterials, respectively, both dispersed in Nafion polymer. p-NP is irreversibly oxidized at +0.9 V (vs. the Ag/AgCl) in solutions of pH 7. The height and potential of the peaks depend on pH in the range from 5 to 11. In acidic media, p-NP yields a well-defined oxidation peak at +0.96 V which gradually increases in height with the concentration of the analyte. In case of differential pulse voltammetry in sulfuric acid solution, the sensitivity is practically the same for both electrodes. The modified electrodes display an unusually wide linear response (from 10 μM to 0.62 mM of p-NP), with a detection limit of 0.6 μM in case of the graphene electrode, and of 1.3 μM in case of the MWNT electrode. FigureDPV responses of graphene and MWNT electrodes to increasing concentrations of p-NP in H2SO4 20 mM solution. Inset: liniar plot of oxidation peak currents with the concentration of p-NP.

[1]  Martin Pumera,et al.  Stacked graphene nanofibers for electrochemical oxidation of DNA bases. , 2010, Physical chemistry chemical physics : PCCP.

[2]  P. Kim,et al.  Experimental observation of the quantum Hall effect and Berry's phase in graphene , 2005, Nature.

[3]  Yuyan Shao,et al.  Graphene Based Electrochemical Sensors and Biosensors: A Review , 2010 .

[4]  A. Govindaraj,et al.  Graphene-based electrochemical supercapacitors , 2008 .

[5]  Chen-Zhong Li,et al.  Probing the Electrochemical Properties of Graphene Nanosheets for Biosensing Applications , 2009 .

[6]  Douglas R. Kauffman,et al.  Graphene versus carbon nanotubes for chemical sensor and fuel cell applications. , 2010, The Analyst.

[7]  Zhenhui Wang,et al.  The separation and determination of nitrophenol isomers by high-performance capillary zone electrophoresis. , 2004, Talanta.

[8]  Ashok Mulchandani,et al.  Amperometric microbial biosensor for p-nitrophenol using Moraxella sp.-modified carbon paste electrode. , 2005, Biosensors & bioelectronics.

[9]  V. Pedrosa,et al.  Electroanalytical determination of 4-nitrophenol by square wave voltammetry on diamond electrodes , 2003 .

[10]  Martin Pumera,et al.  Influence of nitric acid treatment of carbon nanotubes on their physico-chemical properties. , 2009, Journal of nanoscience and nanotechnology.

[11]  Percy Calvo-Marzal,et al.  Electroanalytical determination of acid phosphatase activity by monitoring p-nitrophenol , 2001 .

[12]  Dimitrios Gournis,et al.  Comparative study of different types of graphenes as electrocatalysts for ascorbic acid , 2010 .

[13]  M. Morris,et al.  High-performance liquid chromatographic analysis of p-nitrophenol and its conjugates in biological samples. , 1990, Journal of chromatography.

[14]  S. Stankovich,et al.  Graphene-based composite materials , 2006, Nature.

[15]  M. Miró,et al.  Multicomponent sequential injection analysis determination of nitro-phenols in waters by on-line liquid-liquid extraction and preconcentration , 2000 .

[16]  Andre K. Geim,et al.  The rise of graphene. , 2007, Nature materials.

[17]  Chen-Zhong Li,et al.  Membraneless enzymatic biofuel cells based on graphene nanosheets. , 2010, Biosensors & bioelectronics.

[18]  John R. Miller,et al.  Graphene Double-Layer Capacitor with ac Line-Filtering Performance , 2010, Science.

[19]  Guang-Chao Zhao,et al.  Graphene-based modified electrode for the direct electron transfer of Cytochrome c and biosensing , 2010 .

[20]  L. A. Avaca,et al.  Sonovoltammetric determination of 4-nitrophenol on diamond electrodes , 2007 .

[21]  Guohua Zhao,et al.  Direct and Simultaneous Determination of Phenol, Hydroquinone and Nitrophenol at Boron-Doped Diamond Film Electrode , 2007 .

[22]  Chunhai Yang Electrochemical Determination of 4-Nitrophenol Using a Single-Wall Carbon Nanotube Film-Coated Glassy Carbon Electrode , 2004 .

[23]  J. Kysar,et al.  Measurement of the Elastic Properties and Intrinsic Strength of Monolayer Graphene , 2008, Science.

[24]  Huafeng Yang,et al.  Direct electrochemistry of glucose oxidase and biosensing for glucose based on graphene. , 2009, Analytical chemistry.

[25]  P. Richter,et al.  Simultaneous Determination of O- and P- Nitrophenol by First Derivative Spectrophotometry , 1999 .

[26]  I. Naranjo-Rodríguez,et al.  Electrochemical Study of 4-Nitrophenol at a Modified Carbon Paste Electrode , 1999 .

[27]  M. Pumera,et al.  Single-, few-, and multilayer graphene not exhibiting significant advantages over graphite microparticles in electroanalysis. , 2010, Analytical chemistry.

[28]  Ji-ti Zhou,et al.  Electrochemical degradation of p-nitrophenol with different processes. , 2010, Journal of environmental sciences.

[29]  L. Drzal,et al.  Simple Fabrication of a Highly Sensitive Glucose Biosensor Using Enzymes Immobilized in Exfoliated Graphite Nanoplatelets Nafion Membrane , 2007 .

[30]  M. Vitali,et al.  Total p‐Nitrophenol Determination in Urine Samples of Subjects Exposed to Parathion and Methyl‐Parathion by SPME and GC/MS , 1999 .

[31]  H. Dai,et al.  Highly conducting graphene sheets and Langmuir-Blodgett films. , 2008, Nature nanotechnology.

[32]  K. Müllen,et al.  Transparent, conductive graphene electrodes for dye-sensitized solar cells. , 2008, Nano letters.

[33]  G. Busca,et al.  Technologies for the removal of phenol from fluid streams: a short review of recent developments. , 2008, Journal of hazardous materials.

[34]  R. Mahajan,et al.  Electrochemical detection of dopamine in the presence of ascorbic acid using graphene modified electrodes. , 2010, Biosensors & bioelectronics.

[35]  Wenjing Hong,et al.  Transparent graphene/PEDOT–PSS composite films as counter electrodes of dye-sensitized solar cells , 2008 .

[36]  Jun Liu,et al.  A graphene-based electrochemical sensor for sensitive detection of paracetamol. , 2010, Talanta.

[37]  M. Pumera,et al.  Platelet graphite nanofibers for electrochemical sensing and biosensing: the influence of graphene sheet orientation. , 2010, Chemistry, an Asian journal.

[38]  Ying Wang,et al.  Application of graphene-modified electrode for selective detection of dopamine , 2009 .

[39]  Martin Pumera,et al.  The electrochemistry of carbon nanotubes: fundamentals and applications. , 2009, Chemistry.

[40]  A. Brega,et al.  Determination of phenol, m-, o- and p-cresol, p-aminophenol and p-nitrophenol in urine by high-performance liquid chromatography. , 1990, Journal of chromatography.

[41]  Shenghui Zhang,et al.  Simultaneous determination of 2-nitrophenol and 4-nitrophenol based on the multi-wall carbon nanotubes Nafion-modified electrode , 2003, Analytical and bioanalytical chemistry.

[42]  Xiaoling Yang,et al.  A novel hydrogen peroxide biosensor based on Au-graphene-HRP-chitosan biocomposites , 2010 .

[43]  Andre K. Geim,et al.  Electric Field Effect in Atomically Thin Carbon Films , 2004, Science.

[44]  Guobao Xu,et al.  Single-walled carbon nanohorn as new solid-phase extraction adsorbent for determination of 4-nitrophenol in water sample. , 2009, Talanta.

[45]  K. S. Do,et al.  Simultaneous determination of parathion and metabolites in serum by HPLC with column switching , 1997 .

[46]  L. Polo-Díez,et al.  Simultaneous flow-injection determination of o- and p-nitrophenol using a photodiode-array detector , 1992 .

[47]  R. McCreery,et al.  Advanced carbon electrode materials for molecular electrochemistry. , 2008, Chemical reviews.

[48]  Adriano Bof de Oliveira,et al.  Voltammetric determination of 4-nitrophenol at a lithium tetracyanoethylenide (LiTCNE) modified glassy carbon electrode. , 2004, Talanta.