Gas-Phase Databases for Quantitative Infrared Spectroscopy

The National Institute of Standards and Technology (NIST) and the Pacific Northwest National Laboratory (PNNL) are each creating quantitative databases containing the vapor-phase infrared spectra of pure chemicals. The digital databases have been created with both laboratory and remote-sensing applications in mind. A spectral resolution of ≈0.1 cm−1 was selected to avoid degrading sharp spectral features, while also realizing that atmospheric broadening typically limits line widths to 0.1 cm−1. Calculated positional (wavenumber, cm−1) uncertainty is ≤0.005 cm−1, while the 1σ statistical uncertainty in absorbance values is <2% for most compounds. The latter was achieved by measuring multiple (typically ≥9) path length–concentration burdens and fitting a weighted Beer's law plot to each wavenumber channel. The two databases include different classes of compounds and were compared using 12 samples. Though these 12 samples span a range of polarities, absorption strengths, and vapor pressures, the data agree to within experimental uncertainties with only one exception.

[1]  Thomas A Blake,et al.  Removing aperture-induced artifacts from Fourier transform infrared intensity values. , 2002, Applied optics.

[2]  Timothy J. Johnson,et al.  Creation of 0.10-cm-1 resolution quantitative infrared spectral libraries for gas samples , 2002, SPIE Optics East.

[3]  Pamela M. Chu,et al.  Infrared Absorptivity Temperature Dependence of Gas Phase Methanol and Sulfur Dioxide | NIST , 2001 .

[4]  J. A. Beukes,et al.  An intercomparison of laboratory measurements of absorption cross sections and integrated absorption intensities for HCFC-22 , 2000 .

[5]  A. A. Chursin,et al.  The 1997 spectroscopic GEISA databank , 1999 .

[6]  P. M. Chu,et al.  The NIST Quantitative Infrared Database , 1999, Journal of Research of the National Institute of Standards and Technology.

[7]  Laurence S. Rothman,et al.  Reprint of: The HITRAN molecular spectroscopic database and HAWKS (HITRAN Atmospheric Workstation): 1996 edition , 1998 .

[8]  J. Bertie Specification of components, methods and parameters in Fourier transform spectroscopy by Michelson and related interferometers (Technical Report) , 1998 .

[9]  E. R. Cohen An Introduction to Error Analysis: The Study of Uncertainties in Physical Measurements , 1998 .

[10]  P. Griffiths,et al.  Effects of Detector Nonlinearity on Spectra Measured on Three Commercial FT-IR Spectrometers , 1998 .

[11]  Peter R. Griffiths,et al.  Evaluation of a System for Generating Quantitatively Accurate Vapor-Phase Infrared Reference Spectra , 1998 .

[12]  J. Brault,et al.  Ghosts and artifacts in Fourier-transform spectrometry. , 1996, Applied optics.

[13]  M. Birk,et al.  Determination of line strengths by Fourier-transform spectroscopy. , 1996, Applied optics.

[14]  A Goldman,et al.  1995 Atmospheric Trace Molecule Spectroscopy (ATMOS) linelist. , 1996, Applied optics.

[15]  Mark C. Abrams,et al.  Phase correction of emission line Fourier transform spectra , 1995 .

[16]  G. Toon,et al.  Practical example of the correction of Fourier-transform spectra for detector nonlinearity. , 1994, Applied optics.

[17]  Noelle A. Scott,et al.  Management and study of spectroscopic information: The GEISA program , 1992 .

[18]  J. J. Remedios,et al.  The effect of sample emission on measurements of spectral parameters using a fourier transform absorption spectrometer , 1992 .

[19]  A. G. Maki,et al.  Wavenumber calibration tables from heterodyne frequency measurements , 1991 .

[20]  Robert A. Toth,et al.  nu-2 band of H2 O-16 - Line strengths and transition frequencies , 1991 .

[21]  D. Chase Nonlinear Detector Response in FT-IR , 1984 .

[22]  D. Chase Phase Correction in FT-IR , 1982 .

[23]  L. Mertz,et al.  Auxiliary computation for Fourier spectrometry , 1967 .

[24]  L. Giver,et al.  Thermal Contamination of BOMEM FTIR Line Shapes , 1992, High Resolution Fourier Transform Spectroscopy.

[25]  J. Johns,et al.  High resolution and the accurate measurement of intensities , 1987 .

[26]  Charles J. Pouchert The Aldrich library of FT-IR spectra , 1985 .

[27]  J. Taylor An Introduction to Error Analysis , 1982 .

[28]  Mark D. Semon,et al.  POSTUSE REVIEW: An Introduction to Error Analysis: The Study of Uncertainties in Physical Measurements , 1982 .

[29]  R. J. Bell,et al.  Introductory Fourier transform spectroscopy , 1972 .