Free‐breathing conformal irradiation of pancreatic cancer

The purpose of this study was to assess treatment margins in free‐breathing irradiation of pancreatic cancer after bone alignment, and evaluate their impact on conformal radiotherapy. Fifteen patients with adenocarcinoma of the head of the pancreas underwent implantation of single fiducial marker. Intrafraction uncertainties were assessed on simulation four‐dimensional computed tomography (4D CT) by calculating maximal intrafraction fiducial excursion (MIFE). In the first ten patients, after bony alignment, the position of the fiducial was identified on weekly acquired megavolt cone‐beam CT (MV‐CBCT). The interfraction residual uncertainties were estimated by measuring the fiducial displacements with respect to the position in the first session. Patient mean (pM) and patient standard deviation (pSD) of fiducial displacement, mean (μM) and standard deviation (μSD) of pM, and root‐mean‐square of pSD (σres) were calculated. In the other five patients, MIFE was added to the residual component to obtain personalized margin. In these patients, conformal kidney sparing (CONKISS) irradiation was planned prescribing 54/45 Gy to PTV1/PTV2. The organ‐at‐risk limits were set according to current NCCN recommendation. No morbidity related to the fiducial marker implantation was recorded. In the first ten patients, along right–left, anterior–posterior, and inferior–superior directions, MIFE was variable (mean±std=0.24±0.13cm,0.31±0.14cm,0.83±0.35cm, respectively) and was at most 0.51, 0.53, and 1.56 cm, respectively. Along the same directions, μM were 0.09,−0.05,−0.05cm,μSD were 0.30, 0.17, 0.33 cm, and σres were 0.35, 0.26, and 0.30 cm, respectively. MIFE was not correlated with pM and pSD. In the five additional patients, it was possible to satisfy recommended dose limits, with the exception of slightly higher doses to small bowel. After bony alignment, the margins for target expansion can be obtained by adding personalized MIFE to the residual interfraction term. Using these margins, conformal free‐breathing irradiation is a reliable option for the treatment of pancreatic cancer. PACS number: 87.55.D‐

[1]  Christopher Moore,et al.  Quantifying motion for pancreatic radiotherapy margin calculation. , 2012, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[2]  Jan-Jakob Sonke,et al.  Quantification of the variability of diaphragm motion and implications for treatment margin construction. , 2012, International journal of radiation oncology, biology, physics.

[3]  J. Cheng,et al.  Practically acquired and modified cone-beam computed tomography images for accurate dose calculation in head and neck cancer , 2011, Strahlentherapie und Onkologie.

[4]  M. Hiraoka,et al.  Interfractional reproducibility in pancreatic position based on four-dimensional computed tomography. , 2011, International journal of radiation oncology, biology, physics.

[5]  S. Zucca,et al.  Prostate Image-Guided Radiotherapy by Megavolt Cone-Beam CT , 2011, Strahlentherapie und Onkologie.

[6]  Matthias Guckenberger,et al.  kV Cone-Beam CT-Based IGRT , 2011, Strahlentherapie und Onkologie.

[7]  Mitsuhiro Nakamura,et al.  Positional reproducibility of pancreatic tumors under end-exhalation breath-hold conditions using a visual feedback technique. , 2011, International journal of radiation oncology, biology, physics.

[8]  P. Kovács,et al.  Conkiss: conformal kidneys sparing 3D noncoplanar radiotherapy treatment for pancreatic cancer as an alternative to IMRT. , 2011, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[9]  V. Bettinardi,et al.  Internal target volume defined by contrast-enhanced 4D-CT scan in unresectable pancreatic tumour: evaluation and reproducibility. , 2010, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[10]  J. Norton,et al.  Interfractional uncertainty in the treatment of pancreatic cancer with radiation. , 2010, International journal of radiation oncology, biology, physics.

[11]  Eric C Ford,et al.  Use of respiratory-correlated four-dimensional computed tomography to determine acceptable treatment margins for locally advanced pancreatic adenocarcinoma. , 2010, International journal of radiation oncology, biology, physics.

[12]  Hiroshi Asakura,et al.  Four-dimensional measurement of intrafractional respiratory motion of pancreatic tumors using a 256 multi-slice CT scanner. , 2009, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[13]  Seong Soo Shin,et al.  Differences in abdominal organ movement between supine and prone positions measured using four-dimensional computed tomography. , 2007, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[14]  S. Adusumilli,et al.  Characterization of pancreatic tumor motion using cine MRI: surrogates for tumor position should be used with caution. , 2007, International journal of radiation oncology, biology, physics.

[15]  X Sharon Qi,et al.  Interfractional variations in patient setup and anatomic change assessed by daily computed tomography. , 2007, International journal of radiation oncology, biology, physics.

[16]  M. V. van Herk,et al.  Impact of geometrical uncertainties on 3D CRT and IMRT dose distributions for lung cancer treatment. , 2006, International journal of radiation oncology, biology, physics.

[17]  Steve B. Jiang,et al.  Synchronized moving aperture radiation therapy (SMART): improvement of breathing pattern reproducibility using respiratory coaching , 2006, Physics in medicine and biology.

[18]  Christopher G Willett,et al.  Quantification of respiration-induced abdominal tumor motion and its impact on IMRT dose distributions. , 2004, International journal of radiation oncology, biology, physics.

[19]  Quynh-Thu Le,et al.  The effectiveness of breath-holding to stabilize lung and pancreas tumors during radiosurgery. , 2002, International journal of radiation oncology, biology, physics.

[20]  A L McKenzie,et al.  How should breathing motion be combined with other errors when drawing margins around clinical target volumes? , 2000, The British journal of radiology.

[21]  H. Chao,et al.  Phase-specific cone beam computed tomography reduces reconstructed volume loss of moving phantom , 2011, Strahlentherapie und Onkologie.

[22]  Marcel van Herk,et al.  Errors and margins in radiotherapy. , 2004, Seminars in radiation oncology.