A nonlinear electrical-thermal model of the skin

Presents a model for the skin which accounts for both the nonlinearities and the asymmetries in its voltage-current characteristic. This model consists of an electrical submodel and a heat transfer submodel. The electrical submodel uses nonlinear devices in which some parameters depend on skin temperature. The heat transfer submodel models the heat exchange between the skin, the surrounding tissues, and the ambient medium and calculates the temperature of the skin to update the necessary parameters of the electrical submodel. The model is based on experiments designed to determine: (1) the dry skin voltage-current characteristic; (2) the changes in the skin breakdown voltage with location; (3) the moist skin voltage-current characteristic; (4) the changes in the voltage-current characteristic of the skin with duration after the onset of stimulation; and (5) the effect of skin temperature on its voltage-current characteristic. During these experiments the authors used 84-mm/sup 2/ square Ag-AgCl electrodes to apply sinusoidal voltage of 0.2 and 20 Hz. The simulations were performed using the Advanced Continuous Simulation Language (ACSL), capable of solving differential and integral equations with variable coefficients. The model predicted the skin behavior satisfactorily for a large range of amplitudes and frequencies. The authors found that the breakdown occurred when the energy delivered to the skin exceeded a threshold. Above this threshold the voltage-current characteristic of the skin became nonlinear and asymmetric and, in a real situation, the subject would experience an uncomfortable sensation which could rapidly develop into pain.<<ETX>>

[1]  D. Lykken,et al.  Square-wave analysis of skin impedance. , 1970, Psychophysiology.

[2]  B. W. Watson,et al.  The effect of the electrolyte applied to the surface of the skin on the measured electrical potential difference in vivo; an explanation of the apparently contradictory results in the literature. , 1975, Physics in medicine and biology.

[3]  R. Edelberg,et al.  BIOPOTENTIALS FROM THE SKIN SURFACE: THE HYDRATION EFFECT * , 1968, Annals of the New York Academy of Sciences.

[4]  Samuel Glasstone,et al.  Textbook of physical chemistry , 1941 .

[5]  S Grimnes,et al.  Pathways of ionic flow through human skin in vivo. , 1984, Acta dermato-venereologica.

[6]  Vincent C. Rideout,et al.  Mathematical and Computer Modeling of Physiological Systems , 1991 .

[7]  J. Jack,et al.  Electric current flow in excitable cells , 1975 .

[8]  Willis J. Tompkins,et al.  Design of Microcomputer-Based Medical Instrumentation , 1981 .

[9]  R. Burnette,et al.  Comparison between the iontophoretic and passive transport of thyrotropin releasing hormone across excised nude mouse skin. , 1986, Journal of pharmaceutical sciences.

[10]  B. Ongpipattanakul,et al.  Characterization of the permselective properties of excised human skin during iontophoresis. , 1987, Journal of pharmaceutical sciences.

[11]  Kurt A. Kaczmarek Optimal electrotactile stimulation waveforms for human information display , 1991 .

[12]  R. Edelberg,et al.  Relation of electrical properties of skin to structure and physiologic state. , 1977, The Journal of investigative dermatology.

[13]  Tatsuma Yamamoto,et al.  Formative Mechanisms of Current Concentration and Breakdown Phenomena Dependent on Direct Current Flow Through the Skin by a Dry Electrode , 1986, IEEE Transactions on Biomedical Engineering.

[14]  R. Scheuplein,et al.  Permeability of the Skin , 1971 .