Improved stability and altered selectivity of tyrosinase based graphite electrodes for detection of phenolic compounds

Abstract The operational and storage stability of tyrosinase biosensors were investigated for different tyrosinase modified electrodes, i.e., plain bulk modified carbon paste electrodes (CPEs), surface modified by simple adsorption to solid graphite electrodes (SGEs), and surface modified by the immobilisation in Eastman AQ, a poly ester–sulphonic acid cation exchanger, and Nafion, a perfluorinated-sulphonated ionomer, on the surface of both CP and SGEs. Factors such as the pH of immobilisation, the enzyme loading, and the polymer concentration were investigated in regards to the influence on the sensitivity, the limit of detection (LOD), the sample throughput (STP), and the operational and storage stability. Both storage and operational stability were improved by immobilisation of tyrosinase in either of the two polymer matrices. For 50 consecutive injections of 50 μM catechol, the response stayed the same for the optimal Eastman and Nafion modified CP and SGEs. After about 42 days 80% and 75% of the original response for the Eastman and Nafion modified tyrosinase electrodes remained, respectively, whereas the tyrosinase bulk-modified CPE and adsorbed tyrosinase SGEs had lost virtually 100% of the original response. The selectivity for nine phenolic compounds were investigated and found to change with the introduction of the polymer membrane. The detection of especially monophenols was improved probably due to their preconcentration into the polymer membranes. The best performing biosensor in terms of sensitivity, LOD, STP, operational and storage stability was reached for one where tyrosinase was immobilised in Nafion, i.e., sensitivity: 11.51 nA/μM, LOD: 0.015 μM catechol, and STP: 36 samples/h. The phenolic content, expressed as catechol equivalents was evaluated in six waste water effluents from tannery industries in Spain and Sweden. The operational stability after 90 consecutive injections of extremely contaminated waste waters showed that the Nafion sensor retained 70% of its initial response.

[1]  Lo Gorton,et al.  Influence of graphite powder, additives and enzyme immobilization procedures on a mediatorless HRP-modified carbon paste electrode for amperometric flow-injection detection of H2O2 , 1995 .

[2]  H. Lidén,et al.  Effects of different additives on a tyrosinase based carbon paste electrode , 1995 .

[3]  J. Dordick Designing Enzymes for Use in Organic Solvents , 1992, Biotechnology progress.

[4]  C. Sonnenschein,et al.  p-Nonyl-phenol: an estrogenic xenobiotic released from "modified" polystyrene. , 1991, Environmental health perspectives.

[5]  Uwe Spohn,et al.  The influence of the carbon paste composition on the performance of an amperometric bienzyme sensor for L‐lactate , 1996 .

[6]  M. Smyth,et al.  Organic phase enzyme electrodes: kinetics and analytical applications , 1997 .

[7]  L. Gorton,et al.  Flow-injection analysis of phenols at a graphite electrode modified with co-immobilised laccase and tyrosinase , 1995 .

[8]  R. Varón,et al.  Analysis of a kinetic model for melanin biosynthesis pathway. , 1992, The Journal of biological chemistry.

[9]  L. Gorton,et al.  Enzymatic determination of glucose in a flow system by catalytic oxidation of the nicotinamide coenzyme at a modified electrode , 1985 .

[10]  W. Maccrehan,et al.  Determination of phenols in petroleum crude oils using liquid chromatography with electrochemical detection , 1987 .

[11]  D. Barceló Environmental analysis : techniques, applications, and quality assurance , 1993 .

[12]  L. Gorton,et al.  Amperometric biosensor for the determination of phenolic compounds using a tyrosinase graphite electrode in a flow injection system. , 1993, Journal of biotechnology.

[13]  Joseph Wang,et al.  Organic-phase enzyme electrode for the determination of trace water in nonaqueous media , 1993 .

[14]  J Wang,et al.  Organic-phase biosensors for monitoring phenol and hydrogen peroxide in pharmaceutical antibacterial products. , 1993, The Analyst.

[15]  A. Soto,et al.  Developmental effects of endocrine-disrupting chemicals in wildlife and humans. , 1993, Environmental health perspectives.

[16]  D. Barceló,et al.  Analysis of industrial effluents to determine endocrine-disrupting chemicals , 1997 .

[17]  D. Barceló,et al.  Persistence of selected pesticides and their phenolic transformation products in natural waters using off-line liquid solid extraction followed by liquid chromatographic techniques , 1997 .

[18]  R. Béliveau,et al.  Development of Biosensors Based on Immobilization of Enzymes in Eastman AQ Polymer Coated with a Layer of Nafion , 1990 .

[19]  L. Gorton,et al.  Development of enzyme-based amperometric sensors for the determination of phenolic compounds , 1995 .

[20]  Ioanis Katakis,et al.  Improved mediated tyrosinase amperometric enzyme electrodes , 1997 .

[21]  L. Gorton,et al.  Improvement of Electrochemical Biosensors Using Enzyme Immobilization from Water−Organic Mixtures with a High Content of Organic Solvent , 1996 .

[22]  R. M. Sharpe,et al.  Are oestrogens involved in falling sperm counts and disorders of the male reproductive tract? , 1993, The Lancet.

[23]  Joseph Wang,et al.  Oxygen-Rich Oxidase Enzyme Electrodes for Operation in Oxygen-Free Solutions , 1998 .

[24]  William A. Telliard,et al.  PRIORITY POLLUTANTS I-A PERSPECTIVES VIEW , 1979 .

[25]  D. Barceló,et al.  Optimisation and validation of an automated solid phase extraction technique coupled on-line to enzyme-based biosensor detection for the determination of phenolic compounds in surface water samples , 1995 .

[26]  B. Mattiasson,et al.  On the importance of the support material for bioorganic synthesis. Influence of water partition between solvent, enzyme and solid support in water-poor reaction media. , 1988, European journal of biochemistry.

[27]  T. Golden,et al.  Permselectivity and ion-exchange properties of Eastman-AQ polymers on glassy carbon electrodes. , 1989, Analytical chemistry.

[28]  Y. Khmelnitsky,et al.  The effect of water content and nature of organic solvent on enzyme activity in low-water media. A quantitative description. , 1991, European journal of biochemistry.

[29]  W. Schuhmann,et al.  New amperometric dehydrogenase electrodes based on electrocatalytic NADH‐oxidation at poly (methylene blue)‐modified electrodes , 1994 .

[30]  C. Mackerer,et al.  32P analysis of DNA adducts in tissues of benzene-treated rats. , 1989, Environmental health perspectives.

[31]  S. Mannino,et al.  Silicone-grease-based immobilisation method for the preparation of enzyme electrodes. , 1989, The Analyst.

[32]  J. Rishpon,et al.  Amperometric glucose sensors based on glucose oxidase immobilized in nafion , 1994 .

[33]  David J. Best,et al.  Amperometric enzyme electrode for the determination of phenols in chloroform , 1988 .

[34]  L. Gorton,et al.  Rate-limiting steps of tyrosinase-modified electrodes for the detection of catechol. , 1996, Analytical chemistry.

[35]  J. Vílchez,et al.  Bioamperometric sensors for phenol based on carbon paste electrodes , 1989 .

[36]  Klaus-Dieter Vorlop,et al.  Methylphenazonium-modified enzyme sensor based on polymer thick films for subnanomolar detection of phenols , 1995 .

[37]  K. Martínek,et al.  Micellar enzymology: its relation to membranology , 1989 .

[38]  D. Bélanger,et al.  Evaluation of nafion as media for glucose oxidase immobilization for the development of an amperometric glucose biosensor , 1992 .

[39]  Niklas Larsson,et al.  Simultaneous monitoring of glucose and l-lactic acid during a fermentation process in an aqueous two-phase system by on-line FIA with microdialysis sampling and dual biosensor detection , 1998 .

[40]  L. Gorton,et al.  Phenol oxidase-based biosensors as selective detection units in column liquid chromatography for the determination of phenolic compounds , 1994 .

[41]  Lo Gorton,et al.  Carbon paste electrodes modified with enzymes, tissues, and cells , 1995 .

[42]  A. Baron,et al.  High-performance liquid chromatography of the phenolic compounds in the juice of some French cider apple varieties , 1991 .

[43]  Claes Brage,et al.  Separation of phenols and aromatic hydrocarbons from biomass tar using aminopropylsilane normal-phase liquid chromatography , 1991 .

[44]  L. Gorton,et al.  An amperometric glucose electrode based on carbon paste, chemically modified with glucose dehydrogenase, nicotinamide adenine dinucleotide, and a phenoxazine mediator, coated with a poly(ester sulfonic acid) cation exchanger , 1991 .

[45]  L. Gorton,et al.  A glucose electrode based on carbon paste chemically modified with a ferrocene-containing siloxane polymer and glucose oxidase, coated with a poly(ester-sulfonic acid) cation-exchanger , 1990 .

[46]  R. Kesting Synthetic Polymeric Membranes: A Structural Perspective , 1985 .

[47]  Jenny Emnéus,et al.  Flow injection analysis of phenolic compounds with carbon paste electrodes modified with tyrosinase purchased from different companies , 1996 .

[48]  S. Cosnier,et al.  Poly(amphiphilic pyrrole)-tyrosinase-peroxidase electrode for amplified flow injection-amperometric detection of phenol , 1996 .

[49]  G. Font,et al.  Ultraviolet spectrophotometric determination of phenols in natural and waste waters with iodine monobromide. , 1987, The Analyst.