Continuous-flow enzymatic determination of creatinine with improved on-line removal of endogenous ammonia

SUMMARY A new continuous-flow automated enzymatic method suitable for the direct determination of creatinine in physiological samples is described. The proposed system utilizes an on-line gas predialysis unit in conjunction with a flow-through enzyme reactor coil and a potentiometric ammonia detector. The enzyme reactor contains immobilized creatinine iminohydrolase (EC 3.5.4.21) which converts creatinine to ammonia and N-methylhydantoin. Ammonia liberated from this reaction is detected downstream with the membrane electrode-based detector. The novel gas predialysis unit effectively removes >99.8% of endogenous ammonia (up to 1 mM) present in the sample. Thus, final peak potentials recorded by the electrode detector are directly proportional to the logarithm of creatinine concentrations present. The method is shown to be precise (< 3%), selective, and capable of accurately determining creatinine in serum and urine samples containing abnormally high endogenous ammonia levels. Determinations of creatinine in serum samples (n = 30) using this new method correlate well with an existing Technicon AutoAnalyzer calorimetric method (r = 0.996).

[1]  M. Mascini,et al.  Ammonia abatement in an enzymatic flow system for the determination of creatinine in blood sera and urine , 1985 .

[2]  M. Meyerhoff,et al.  Membrane-dialzer injection loop for enhancing the selectivity of anion-responsive liquid-membrane electrodes in flow systems. Part 1. A sensing system for NOx and nitrite , 1986 .

[3]  N. Tietz Fundamentals of Clinical Chemistry , 1970 .

[4]  D. Matthews,et al.  Estimation of alpha-amino nitrogen in plasma and urine by the colorimetric ninhydrin reaction , 1964, Journal of clinical pathology.

[5]  M. Meyerhoff,et al.  On-line gas dialyzer for automated enzymatic analysis with potentiometric ammonia detection. , 1983, Analytical chemistry.

[6]  J. Goodwin The colorimetric estimation of plasma amino nitrogen with DNFB. , 1968, Clinical chemistry.

[7]  S. Gerard,et al.  Characterization of creatinine error in ketotic patients. A prospective comparison of alkaline picrate methods with an enzymatic method. , 1985, American journal of clinical pathology.

[8]  G. Guilbault,et al.  Fluorometric enzymatic determination of serum creatinine on the surface of silicone-rubber pads. , 1980, Clinica chimica acta; international journal of clinical chemistry.

[9]  M. Tabata,et al.  Automated assay of creatinine in serum as simplified by the use of immobilized enzymes, creatinine deiminase, and glutamate dehydrogenase. , 1983, Analytical biochemistry.

[10]  Kunio Kihara,et al.  Determination of creatinine with a sensor based on immobilized glutamate dehydrogenase and creatinine deiminase , 1986 .

[11]  D. Massart,et al.  Streaming potentials in automatic potentiometric systems , 1974 .

[12]  R. K. Kobos Enzyme-based electrochemical biosensors , 1987 .

[13]  M. Meyerhoff,et al.  Automated Determination of Ammonia with a Potentiometric Gas Sensor and Flowing Internal Electrolyte , 1981 .

[14]  G. Guilbault,et al.  Creatinine-selective enzyme electrodes , 1983 .

[15]  N. Constantsas,et al.  EXCRETION OF AMINO ACIDS IN CHILDHOOD. A RELIABLE METHOD FOR THE DETERMINATION OF AMINO ACID NITROGEN IN URINE. , 1964, Clinica chimica acta; international journal of clinical chemistry.

[16]  M. Mascini,et al.  Determination of creatinine in clinical samples with a creatininase reactor and an ammonia probe , 1982 .

[17]  E. Wong,et al.  Kinetic serum creatinine assays. II. A critical evaluation and review. , 1980, Clinical chemistry.

[18]  L. Prencipe,et al.  Enzymic assay of creatinine in serum and urine with creatinine iminohydrolase and glutamate dehydrogenase. , 1982, Clinical chemistry.