Monitoring of interarea oscillation mode by synchronized phasor measurement

There is a low-frequency interarea oscillation mode in middle and western 60-Hz areas of Japan. Its stability determines available transfer capacity of a tie-line. We propose a method of monitoring its stability by phasor measurements synchronized using the global positioning system. The phase angle between two places deviates randomly. However, its Fourier spectrum shows a clear peak corresponding to the interarea mode. We estimate its frequency and damping from the spectrum. The estimation results agree well with those obtained by curve fitting for large disturbances. It is also possible to estimate the eigenvector. We examine how the eigenvalue varies with the total generation and power flow in the areas.

[1]  R. E. Wilson Methods and uses of precise time in power systems , 1992 .

[2]  C. W. Taylor,et al.  Recording and analyzing the July 2 cascading outage [Western USA power system] , 1997 .

[3]  James S. Thorp,et al.  IEEE Standard for Synchrophasors for Power Systems , 1998 .

[4]  N. Kakimoto,et al.  Instability of interarea oscillation mode by autoparametric resonance , 2004, IEEE Transactions on Power Systems.

[5]  T. W. Cease,et al.  Synchronized phasor measurements of a power system event , 1994 .

[6]  D. N. Kosterev,et al.  Feasibility study of using synchronized phasor measurements for generator dropping controls in the Colstrip System , 1998 .

[7]  A.G. Phadke,et al.  Synchronized phasor measurements in power systems , 1993, IEEE Computer Applications in Power.

[8]  J. Tukey,et al.  An algorithm for the machine calculation of complex Fourier series , 1965 .

[9]  O. Faucon,et al.  Coordinated defense plan protects against transient instabilities , 1997 .

[10]  Takuhei Hashiguchi,et al.  Analysis of Generator Oscillation Characteristics Based on Multiple Synchronized Phasor Measurements , 2003 .

[11]  J. F. Hauer,et al.  Keeping an eye on power system dynamics , 1997 .

[12]  J. F. Hauer,et al.  Initial results in Prony analysis of power system response signals , 1990 .

[13]  A.G. Phadke,et al.  Adaptive out-of-step relaying using phasor measurement techniques , 1993, IEEE Computer Applications in Power.

[14]  L. Hossenlopp,et al.  Measurement of voltage phase for the French future defence plan against losses of synchronism , 1992 .

[15]  Innocent Kamwa,et al.  Wide-area measurement based stabilizing control of large power systems-a decentralized/hierarchical approach , 2001 .

[16]  T. E. Hull,et al.  Random Number Generators , 1962 .

[17]  Daniel J. Trudnowski,et al.  A procedure for oscillatory parameter identification , 1994 .