Low-dose lung cancer screening with photon-counting CT: a feasibility study

To evaluate the feasibility of using a whole-body photon-counting detector (PCD) CT scanner for low-dose lung cancer screening compared to a conventional energy integrating detector (EID) system. Radiation dose-matched EID and PCD scans of the COPDGene 2 phantom were acquired at different radiation dose levels (CTDIvol: 3.0, 1.5, and 0.75 mGy) and different tube voltages (120, 100, and 80 kVp). EID and PCD images were compared for quantitative Hounsfield unit (HU) accuracy, noise levels, and contrast-to-noise ratios (CNR) for detection of ground-glass nodules (GGN) and emphysema. The PCD HU accuracy was better than EID for water at all scan parameters. PCD HU stability for lung, GGN and emphysema regions were superior to EID and PCD attenuation values were more reproducible than EID for all scan parameters (all P  <  0.01), while HUs for lung, GGN and emphysema ROIs changed significantly for EID with decreasing dose (all P  <  0.001). PCD showed lower noise levels at the lowest dose setting at 120, 100 and 80 kVp (15.2  ±  0.3 HU versus 15.8  ±  0.2 HU, P  =  0.03; 16.1  ±  0.3 HU versus 18.0  ±  0.4 HU, P  =  0.003; and 16.1  ±  0.3 HU versus 17.9  ±  0.3 HU, P  =  0.001, respectively), resulting in superior CNR for evaluation of GGNs and emphysema at 100 and 80 kVp. PCD provided better HU stability for lung, ground-glass, and emphysema-equivalent foams at lower radiation dose settings with better reproducibility than EID. Additionally, PCD showed up to 10% less noise, and 11% higher CNR at 0.75 mGy for both 100 and 80 kVp. PCD technology may help reduce radiation exposure in lung cancer screening while maintaining diagnostic quality.

[1]  Yunsu Choi,et al.  Quantitative material decomposition using spectral computed tomography with an energy-resolved photon-counting detector , 2014, Physics in medicine and biology.

[2]  Thorsten M. Buzug,et al.  Threshold optimization for efficient contrast imaging with quantum counting CT detectors , 2013, Medical Imaging.

[3]  Johan H C Reiber,et al.  Quality control in longitudinal studies with computed tomographic densitometry of the lungs. , 2008, Proceedings of the American Thoracic Society.

[4]  P Guerra,et al.  Development of a simplified simulation model for performance characterization of a pixellated CdZnTe multimodality imaging system , 2008, Physics in medicine and biology.

[5]  Katsuyuki Taguchi,et al.  A cascaded model of spectral distortions due to spectral response effects and pulse pileup effects in a photon-counting x-ray detector for CT. , 2014, Medical physics.

[6]  Jongduk Baek,et al.  To bin or not to bin? The effect of CT system limiting resolution on noise and detectability , 2013, Physics in medicine and biology.

[7]  E. Hoffman,et al.  Very Low-Dose (0.15 mGy) Chest CT Protocols Using the COPDGene 2 Test Object and a Third-Generation Dual-Source CT Scanner With Corresponding Third-Generation Iterative Reconstruction Software , 2015, Investigative radiology.

[8]  Jesse Tanguay,et al.  The role of x-ray Swank factor in energy-resolving photon-counting imaging. , 2010, Medical physics.

[9]  S. Armato,et al.  Role of the Quantitative Imaging Biomarker Alliance in optimizing CT for the evaluation of lung cancer screen-detected nodules. , 2015, Journal of the American College of Radiology : JACR.

[10]  Baiyu Chen,et al.  Evaluation of conventional imaging performance in a research whole-body CT system with a photon-counting detector array , 2016, Physics in medicine and biology.

[11]  A. Jemal,et al.  Global Cancer Statistics , 2011 .

[12]  Takeshi Nakaura,et al.  Detection of Nodules Showing Ground-Glass Opacity in the Lungs at Low-Dose Multidetector Computed Tomography: Phantom and Clinical Study , 2009, Journal of computer assisted tomography.

[13]  J. Schlomka,et al.  Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography , 2008, Physics in medicine and biology.

[14]  Taly Gilat Schmidt,et al.  Optimal "image-based" weighting for energy-resolved CT. , 2009, Medical physics.

[15]  Robert L Dixon,et al.  A new look at CT dose measurement: beyond CTDI. , 2003, Medical physics.

[16]  Amir Pourmorteza,et al.  Abdominal Imaging with Contrast-enhanced Photon-counting CT: First Human Experience. , 2016, Radiology.

[17]  Karl Stierstorfer,et al.  Photon counting CT at elevated X-ray tube currents: contrast stability, image noise and multi-energy performance , 2014, Medical Imaging.

[18]  C. Gatsonis,et al.  Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic Screening , 2012 .

[19]  Thorsten M. Buzug,et al.  Investigation of ultra low-dose scans in the context of quantum-counting clinical CT , 2012, Medical Imaging.

[20]  A. Macovski,et al.  Energy-selective reconstructions in X-ray computerised tomography , 1976, Physics in medicine and biology.

[21]  J. Iwanczyk,et al.  Photon Counting Energy Dispersive Detector Arrays for X-ray Imaging , 2007, IEEE Transactions on Nuclear Science.

[22]  Cheng Xu,et al.  Evaluation of Energy Loss and Charge Sharing in Cadmium Telluride Detectors for Photon-Counting Computed Tomography , 2011, IEEE Transactions on Nuclear Science.

[23]  E. Hoffman,et al.  Sinogram Affirmed Iterative Reconstruction (SAFIRE) versus weighted filtered back projection (WFBP) effects on quantitative measure in the COPDGene 2 test object. , 2014, Medical physics.

[24]  R. E. Alvarez,et al.  Energy-Selective Radiography A Review , 1986 .

[25]  P F Judy,et al.  Reference standard and statistical model for intersite and temporal comparisons of CT attenuation in a multicenter quantitative lung study. , 2012, Medical physics.

[26]  K. Taguchi,et al.  Vision 20/20: Single photon counting x-ray detectors in medical imaging. , 2013, Medical physics.

[27]  Karl Stierstorfer,et al.  Multi-energy performance of a research prototype CT scanner with small-pixel counting detector , 2013, Medical Imaging.

[28]  J. Mayo,et al.  Radiation exposure at chest CT: a statement of the Fleischner Society. , 2003, Radiology.