Impacts of Three MMC-HVDC Configurations on AC System Stability Under DC Line Faults

This paper analyzes the dc line fault transient stability characteristics of AC/DC power systems with three different modular multilevel converter based high voltage direct current (MMC-HVDC) configurations. The first configuration is half bridge sub-module based MMC (H-MMC) HVDC configuration, which clears dc line faults by tripping the ac circuit breakers. The clamp double sub-module (CDSM) based MMC (C-MMC) HVDC configuration with dc line fault clearance ability constitutes the second configuration. A line-commutated converter (LCC) and MMC hybrid HVDC configuration with dc line fault clearance ability, named LCC-diode-MMC (LCC-D-MMC), is the third configuration. The detailed processes of clearing dc line faults in three MMC-HVDC configurations are analyzed. The equal area criterion is utilized to analyze the dc line fault transient processes. Besides, to evaluate the power system transient stability characteristics in three MMC-HVDC configurations, an index, called critical ac transmitted power (Pac_critical), is proposed. Under the same dc line to ground fault, transient stability characteristics of three test systems based on the three different MMC-HVDC configurations are compared. Excellent performance of the LCC-D-MMC HVDC configuration under the dc line fault is demonstrated through comparison of Pac_critical in the three test systems. Finally, the study is extended to a modified New England 39-bus system, and the simulation results also correspond with the theoretical analysis.

[1]  Rainer Marquardt,et al.  Modular Multilevel Converter topologies with DC-Short circuit current limitation , 2011, 8th International Conference on Power Electronics - ECCE Asia.

[2]  Zhe Chen,et al.  A Flexible Power Control Method of VSC-HVDC Link for the Enhancement of Effective Short-Circuit Ratio in a Hybrid Multi-Infeed HVDC System , 2013, IEEE Transactions on Power Systems.

[3]  Hongyang Huang,et al.  Improving Performance of Multi-Infeed HVDC Systems Using Grid Dynamic Segmentation Technique Based on Fault Current Limiters , 2012, IEEE Transactions on Power Systems.

[4]  Zheng Xu,et al.  Self-Start Control With Grouping Sequentially Precharge for the C-MMC-Based HVDC System , 2014, IEEE Transactions on Power Delivery.

[5]  Fainan Hassan,et al.  Design and simulation of a modular multi-level converter for MVDC application , 2011, 2011 IEEE International Symposium on Industrial Electronics.

[6]  Liang Haifeng,et al.  Research on hybrid HVDC , 2004, 2004 International Conference on Power System Technology, 2004. PowerCon 2004..

[7]  M.P. Bahrman,et al.  The ABCs of HVDC transmission technologies , 2007, IEEE Power and Energy Magazine.

[8]  D. R. Critchley,et al.  A ew Hybrid Multi-Level Voltage-Source Converter with DC Fault Blocking Capability , 2010 .

[9]  J. Peralta,et al.  Detailed and Averaged Models for a 401-Level MMC–HVDC System , 2012, IEEE Transactions on Power Delivery.

[10]  Gengyin Li,et al.  Operational Mechanism and Characteristic Analysis of Novel Hybrid HVDC system , 2006, 2006 International Conference on Power System Technology.

[11]  C M Franck,et al.  HVDC Circuit Breakers: A Review Identifying Future Research Needs , 2011, IEEE Transactions on Power Delivery.

[12]  Yi Hu,et al.  Ultra High Voltage Transmission in China: Developments, Current Status and Future Prospects , 2009, Proceedings of the IEEE.

[13]  Ani Gole,et al.  Analysis of dual-infeed HVDC with LCC-HVDC and VSC-HVDC , 2012, 2013 IEEE Power & Energy Society General Meeting.