Application of a proposed overcurrent relay in radial distribution networks

This paper contains the application criteria and coordination process for a proposed overcurrent relay in a radial power system with feed from one or multiple sources. This relay uses independent functions to detect faults and to calculate the operation time. Also this relay uses a time element function that allows it to reduce the time relay operation, enhancing the backup protection. Some of the proposed approaches improve the sensitivity of the relay. The selection of the best approach in the proposed relay is defined by the needs of the application. The proposed protection can be considered as an additional function protection to conventional overcurrent relays.

[1]  K. K. Li,et al.  Protection relay coordination on ring-fed distribution network with distributed generations , 2002, 2002 IEEE Region 10 Conference on Computers, Communications, Control and Power Engineering. TENCOM '02. Proceedings..

[2]  I. Zamora,et al.  New Method for Detecting Low Current Faults in Electrical Distribution Systems , 2007, IEEE Transactions on Power Delivery.

[3]  D. N. Vishwakarma,et al.  ANN based directional overcurrent relay , 2001, 2001 IEEE/PES Transmission and Distribution Conference and Exposition. Developing New Perspectives (Cat. No.01CH37294).

[4]  Arturo Conde Enríquez,et al.  Enhanced time overcurrent coordination , 2006 .

[5]  P. A. Kotos,et al.  IEEE standard inverse-time characteristic equations for overcurrent relays , 1999 .

[6]  Zhang Zhe,et al.  The research of the overcurrent relays based on phase-to-phase differential current -adaptive setting and coordination , 2003, 2003 IEEE PES Transmission and Distribution Conference and Exposition (IEEE Cat. No.03CH37495).

[7]  P. Crossley,et al.  Design of a protection relay for use with a measuring CT , 2000, 2000 Power Engineering Society Summer Meeting (Cat. No.00CH37134).

[8]  A. G. Phadke,et al.  Feasibility of adaptive distribution protection system using computer overcurrent relaying concept , 1988 .

[9]  A. Conde,et al.  Operation logic proposed for time overcurrent relays , 2006, 2006 IEEE Power Engineering Society General Meeting.

[10]  C. B. Cooper,et al.  IEEE Recommended Practice for Electric Power Distribution for Industrial Plants , 1987 .

[11]  J. Faiz,et al.  Improved Overcurrent Protection Using Symmetrical Components , 2007, IEEE Transactions on Power Delivery.

[12]  A. Girgis,et al.  Effect of distributed generation on protective device coordination in distribution system , 2001, LESCOPE 01. 2001 Large Engineering Systems Conference on Power Engineering. Conference Proceedings. Theme: Powering Beyond 2001 (Cat. No.01ex490).