Stator voltage sensorless DFIG with low voltage ride-through capability using series and parallel grid side converters

Due to the drastic increase of the wind turbines installed capacity, the grid integration codes address many restrictions over their performance during both normal and abnormal conditions. The main aim of such codes is to operate the wind turbines like other conventional power sources. In this paper a series grid side converter is added to the conventional DFIG wind turbine configuration to add low voltage ride through capability. This target is achieved without the need to neither measure nor estimate the stator voltage or flux, hence simplifying the control scheme. The system model and the control scheme for 1.5 MW DFIG wind turbine are constructed and simulated using MATLAB/SIMULINK environment. The simulation results are intensively proving the effectiveness of the proposed scheme.

[1]  Giri Venkataramanan,et al.  Unbalanced Voltage Sag Ride-Through of a Doubly Fed Induction Generator Wind Turbine With Series Grid-Side Converter , 2009 .

[2]  Shao Zhang,et al.  Advanced Control of Series Voltage Compensation to Enhance Wind Turbine Ride Through , 2012, IEEE Transactions on Power Electronics.

[3]  Giri Venkataramanan,et al.  Unbalanced Voltage Sag Ride-Through of a Doubly Fed Induction Generator Wind Turbine With Series Grid-Side Converter , 2009, IEEE Transactions on Industry Applications.

[4]  Dong-Choon Lee,et al.  A Fault Ride-Through Technique of DFIG Wind Turbine Systems Using Dynamic Voltage Restorers , 2011, IEEE Transactions on Energy Conversion.

[5]  B. Singh,et al.  Performance evaluation of series and parallel connected grid side converters of DFIG , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[6]  Antje Winkel Vector Control And Dynamics Of Ac Drives , 2016 .

[7]  I. Erlich,et al.  Performance Evaluation of New Series Connected Grid-Side Converter of Doubly-Fed Induction Generator , 2008, 2008 Joint International Conference on Power System Technology and IEEE Power India Conference.

[8]  Stavros A. Papathanassiou,et al.  A review of grid code technical requirements for wind farms , 2009 .

[9]  J. Morren,et al.  Short-Circuit Current of Wind Turbines With Doubly Fed Induction Generator , 2007, IEEE Transactions on Energy Conversion.

[10]  K. H. Ahmed,et al.  Low voltage ride-through capability enhancement of a DFIG wind turbine using a dynamic voltage restorer with Adaptive Fuzzy PI controller , 2013, 2013 International Conference on Renewable Energy Research and Applications (ICRERA).

[11]  Zhe Chen,et al.  Enhanced Control of a DFIG-Based Wind-Power Generation System With Series Grid-Side Converter Under Unbalanced Grid Voltage Conditions , 2013, IEEE Transactions on Power Electronics.

[12]  C Wessels,et al.  Fault Ride-Through of a DFIG Wind Turbine Using a Dynamic Voltage Restorer During Symmetrical and Asymmetrical Grid Faults , 2011, IEEE Transactions on Power Electronics.

[13]  J. Morren,et al.  Ridethrough of wind turbines with doubly-fed induction generator during a voltage dip , 2005, IEEE Transactions on Energy Conversion.

[14]  A. Petersson Analysis, Modeling and Control of Doubly-Fed Induction Generators for Wind Turbines , 2005 .

[15]  I. Erlich,et al.  Grid code requirements concerning connection and operation of wind turbines in Germany , 2005, IEEE Power Engineering Society General Meeting, 2005.