A Novel Technique for Detection of Time Delay Switch Attack on Load Frequency Control

In this paper, we focus on the estimation of time delays caused by adversaries in the sensing loop (SL). Based on the literature review, time delay switch (TDS) attacks could make any control system, in particular a power control system, unstable. Therefore, future smart grids will have to use advanced methods to provide better situational awareness of power grid states keeping smart grids reliable and safe from TDS attacks. Here, we introduce a simple method for preventing time delay switch attack on networked control systems. The method relies on an estimator that will estimate and track time delays introduced by an adversary. Knowing the maximum tolerable time delay of the plant’s optimal controller for which the plant remains stable, a time-delay detector issues an alarm signal when the estimated time delay is larger than the minimum one and directs the system to alarm state. In an alarm state, the plant operates under the control of an emergency controller that is local to the plant and remains in this mode until the networked control system state is restored. This method is an inexpensive and simple way to guarantee that an industrial control system remains stable and secure.

[1]  Wei Yu,et al.  On time desynchronization attack against IEEE 1588 protocol in power grid systems , 2013, 2013 IEEE Energytech.

[2]  Yonghong Tan,et al.  Time-varying time-delay estimation for nonlinear systems using neural networks , 2004 .

[3]  I. C. Decker,et al.  Wide-Area Measurements-Based Two-Level Control Design Considering Signal Transmission Delay , 2009, IEEE Transactions on Power Systems.

[4]  Xiao Jian,et al.  Adaptive Delay Estimation and Control of Networked Control systems , 2006, 2006 International Symposium on Communications and Information Technologies.

[5]  H. Beńıtez-Pérez,et al.  NETWORKED CONTROL SYSTEMS DESIGN CONSIDERING SCHEDULING RESTRICTIONS AND LOCAL FAULTS , 2012 .

[6]  E.H. Abed,et al.  Delaying instability and voltage collapse in power systems using SVCs with washout filter-aided feedback , 2005, Proceedings of the 2005, American Control Conference, 2005..

[7]  Mohamed Zribi,et al.  ON THE CONTROL OF TIME DELAY POWER SYSTEMS , 2013 .

[8]  Ganesh K. Venayagamoorthy,et al.  Real-time implementation of a measurement-based adaptive wide-area control system considering communication delays , 2008 .

[9]  Farhad Kamyab,et al.  Demand Response Program in Smart Grid Using Supply Function Bidding Mechanism , 2016, IEEE Transactions on Smart Grid.

[10]  Göran N Ericsson,et al.  Cyber Security and Power System Communication—Essential Parts of a Smart Grid Infrastructure , 2010, IEEE Transactions on Power Delivery.

[11]  G.T. Heydt,et al.  Evaluation of time delay effects to wide-area power system stabilizer design , 2004, IEEE Transactions on Power Systems.

[12]  Federico Milano,et al.  Impact of Time Delays on Power System Stability , 2012, IEEE Transactions on Circuits and Systems I: Regular Papers.

[13]  Arman Sargolzaei,et al.  Assessment of He's Homotopy Perturbation Method for Optimal Control of Linear Time-Delay Systems , 2013 .

[14]  Y. Tan,et al.  TIME-VARYING TIME-DELAY ESTIMATION FOR NONLINEAR SYSTEMS USING NEURAL NETWORKS , 2004 .

[15]  Kang Yen,et al.  Delayed inputs attack on load frequency control in smart grid , 2014, ISGT 2014.

[16]  Luca Schenato,et al.  Optimal Estimation in Networked Control Systems Subject to Random Delay and Packet Drop , 2008, IEEE Transactions on Automatic Control.

[17]  M. Mahmoud Robust Control and Filtering for Time-Delay Systems , 2000 .

[18]  Shaocheng Tong,et al.  OBSERVER-BASED ADAPTIVE FUZZY BACKSTEPPING CONTROL FOR STRICT-FEEDBACK STOCHASTIC NONLINEAR SYSTEMS WITH TIME DELAYS , 2012 .

[19]  Innocent Kamwa,et al.  Wide-area measurement based stabilizing control of large power systems-a decentralized/hierarchical approach , 2001 .

[20]  A. Benzaouia,et al.  FAULT DETECTION FOR UNCERTAIN DELAYED SWITCHING DISCRETE-TIME SYSTEMS , 2012 .

[21]  B. Chaudhuri,et al.  Wide-area measurement-based stabilizing control of power system considering signal transmission delay , 2004, IEEE Transactions on Power Systems.

[22]  Ismail Güvenç,et al.  Determination of the minimum-variance unbiased estimator for DC power-flow estimation , 2014, IECON 2014 - 40th Annual Conference of the IEEE Industrial Electronics Society.

[23]  Arman Sargolzaei,et al.  Time-Delay Switch Attack on Load Frequency Control in Smart Grid , 2013 .

[24]  Cao Yijia,et al.  Wide-area TCSC controller design in consideration of feedback signals' time delays , 2005, IEEE Power Engineering Society General Meeting, 2005.

[25]  Mahmoud-Reza Haghifam,et al.  Load management using multi-agent systems in smart distribution network , 2013, 2013 IEEE Power & Energy Society General Meeting.

[26]  Min Wu,et al.  Delay-Dependent Robust Load Frequency Control for Time Delay Power Systems , 2013, IEEE Transactions on Power Systems.

[27]  Zuyi Li,et al.  Modeling Load Redistribution Attacks in Power Systems , 2011, IEEE Transactions on Smart Grid.