Improved attenuation correction via appropriate selection of respiratory-correlated PET data

PURPOSE We propose a respiratory-correlated PET data processing method (called "BH-CT-based") based on breath-hold CT acquisition to reduce the smearing effect and improve the attenuation correction. The resulting images are compared with the ungated PET images acquired using a standard, free-breathing clinical protocol. METHODS The BH-CT-based method consisted of a list-mode acquisition with simultaneous respiratory signal recording. An additional breath-hold CT acquisition was also performed in order to define a tissue position from which PET events can be selected. A phantom study featured a 0.5-ml sphere (filled with 18F-fluorodeoxyglucose ((18)F-FDG) solution) pushed onto a rubber balloon (filled with (18)F-FDG solution and iodinated contrast agent). The feasibility of the BH-CT-based method was also assessed in two patients. RESULTS In the phantom study, the contrast-to-noise ratios (CNRs) were -1.6 for the Ungated volume and 5.1 for the BH-CT-based volume. For patients, CNRs were higher for BH-CT-based volumes than those for Ungated volumes (17.3 vs. 6.3 and 7.3 vs. 3.8, for patients 1 and 2, respectively). Bias-variance measurements were performed and yielded bias reduction of 40% with BH-CT-based. CONCLUSION The application of a BH-CT-based method decreases motion bias in PET images. This method resolves issues related to both PET-to-CT misregistration and erroneous attenuation correction and increases lesion detectability.

[1]  R. Wahl,et al.  PET/CT: comparison of quantitative tracer uptake between germanium and CT transmission attenuation-corrected images. , 2002, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[2]  Ursula Nestle,et al.  Target volume definition for 18F-FDG PET-positive lymph nodes in radiotherapy of patients with non-small cell lung cancer , 2007, European Journal of Nuclear Medicine and Molecular Imaging.

[3]  Paul Kinahan,et al.  Attenuation correction for a combined 3D PET/CT scanner. , 1998, Medical physics.

[4]  M. Defrise,et al.  Fast reconstruction of 3-D PET data with accurate statistical modeling , 1997, 1997 IEEE Nuclear Science Symposium Conference Record.

[5]  Jonathon A Nye,et al.  Minimizing artifacts resulting from respiratory and cardiac motion by optimization of the transmission scan in cardiac PET/CT. , 2007, Medical physics.

[6]  W E Snyder,et al.  Performance evaluation of filtered backprojection reconstruction and iterative reconstruction methods for PET images , 1998, Comput. Biol. Medicine.

[7]  Thomas K. Lewellen,et al.  Improved quantitation for PET/CT image reconstruction with system modeling and anatomical priors , 2005, SPIE Medical Imaging.

[8]  Heiko Schöder,et al.  Deep-inspiration breath-hold PET/CT of the thorax. , 2007, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[9]  Cyrill Burger,et al.  Respiration-induced attenuation artifact at PET/CT: technical considerations. , 2003, Radiology.

[10]  E Yorke,et al.  Four-dimensional (4D) PET/CT imaging of the thorax. , 2004, Medical physics.

[11]  Roberta Matheoud,et al.  Performance characteristics obtained for a new 3-dimensional lutetium oxyorthosilicate-based whole-body PET/CT scanner with the National Electrical Manufacturers Association NU 2-2001 standard. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[12]  Tinsu Pan,et al.  Attenuation correction of PET cardiac data with low-dose average CT in PET/CT. , 2006, Medical physics.

[13]  A Sánchez Salmón,et al.  PET in abdominal pathology: advantages and limitations. , 2006, Abdominal imaging.

[14]  R. Coleman,et al.  Applications of PET in lung cancer. , 1998, Seminars in nuclear medicine.

[15]  D. Visvikis,et al.  CT-based attenuation correction in the calculation of semi-quantitative indices of [18F]FDG uptake in PET , 2003, European Journal of Nuclear Medicine and Molecular Imaging.

[16]  Tinsu Pan,et al.  Design of respiration averaged CT for attenuation correction of the PET data from PET/CT. , 2007, Medical physics.

[17]  M E Phelps,et al.  Quantitation in Positron Emission Computed Tomography: 6. Effect of Nonuniform Resolution , 1982, Journal of computer assisted tomography.

[18]  Hans-Ulrich Kauczor,et al.  Measurement of tumor diameter-dependent mobility of lung tumors by dynamic MRI. , 2004, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[19]  Stefan Eberl,et al.  Optimizing injected dose in clinical PET by accurately modeling the counting-rate response functions specific to individual patient scans. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[20]  O. Schober,et al.  Respiratory gating in positron emission tomography: a quantitative comparison of different gating schemes. , 2007, Medical physics.

[21]  G Bosmans,et al.  Respiratory-gated CT as a tool for the simulation of breathing artifacts in PET and PET/CT. , 2006, Medical physics.

[22]  A. Pevsner,et al.  The CT motion quantitation of lung lesions and its impact on PET-measured SUVs. , 2004, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[23]  Cyrill Burger,et al.  PET-CT image co-registration in the thorax: influence of respiration , 2002, European Journal of Nuclear Medicine and Molecular Imaging.

[24]  Thomas Beyer,et al.  Non-small cell lung cancer: dual-modality PET/CT in preoperative staging. , 2003, Radiology.

[25]  David W Townsend,et al.  Time Course of Early Response to Chemotherapy in Non–Small Cell Lung Cancer Patients with 18F-FDG PET/CT , 2007, Journal of Nuclear Medicine.

[26]  Ravindra Manjeshwar,et al.  Theoretical Comparison of Motion Correction Techniques for PET Image Reconstruction , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[27]  E. Hoffman,et al.  Quantitation in Positron Emission Computed Tomography: 1. Effect of Object Size , 1979, Journal of computer assisted tomography.

[28]  Yuji Nakamoto,et al.  Respiratory motion artifacts on PET emission images obtained using CT attenuation correction on PET-CT , 2003, European Journal of Nuclear Medicine and Molecular Imaging.

[29]  Michel Defrise,et al.  Exact and approximate rebinning algorithms for 3-D PET data , 1997, IEEE Transactions on Medical Imaging.

[30]  O. Wade,et al.  Movements of the thoracic cage and diaphragm in respiration * , 1954, The Journal of physiology.

[31]  R. Castillo,et al.  Attenuation correction of PET images with respiration-averaged CT images in PET/CT. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[32]  Yukiko Arisaka,et al.  18F-FDG uptake as a biologic prognostic factor for recurrence in patients with surgically resected non-small cell lung cancer. , 2002, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[33]  T. Tsujikawa,et al.  Accuracy of PET for diagnosis of solid pulmonary lesions with 18F-FDG uptake below the standardized uptake value of 2.5. , 2006, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[34]  D. Hellwig,et al.  18F-FDG PET for Mediastinal Staging of Lung Cancer: Which SUV Threshold Makes Sense? , 2007, Journal of Nuclear Medicine.

[35]  C. C. Watson,et al.  New, faster, image-based scatter correction for 3D PET , 1999, 1999 IEEE Nuclear Science Symposium. Conference Record. 1999 Nuclear Science Symposium and Medical Imaging Conference (Cat. No.99CH37019).

[36]  G Bosmans,et al.  Phased attenuation correction in respiration correlated computed tomography/positron emitted tomography. , 2006, Medical physics.

[37]  C. Comtat,et al.  Fast reconstruction of 3-D PET data with accurate statistical modeling , 1997 .

[38]  H Anno,et al.  Minimum scan speeds for suppression of motion artifacts in CT. , 1992, Radiology.

[39]  S. Gulec,et al.  Optimization of FDG-PET/CT imaging protocol for evaluation of patients with primary and metastatic liver disease , 2007, International seminars in surgical oncology : ISSO.

[40]  Loïc Fin,et al.  AW-OSEM parameter optimization for selected events related to the breath-hold CT position in respiratory-gated pet acquisitions , 2008, 2008 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro.