Optimization design of solar enhanced natural draft dry cooling tower

This paper proposed an optimization scheme for solar enhanced natural draft dry cooling tower design, in which a detailed cost model was proposed including capital, labour, maintenance and operation costs of each component. Based on the developed cost model, the optimal design option can be identified in terms of the relatively lower annual cost and the relatively higher total extra income over the Solar Enhanced Natural Draft Dry Cooling Tower (SENDDCT) lifetime. As a case study, a SENDDCT was optimally designed to meet the cooling demand for a 50 MW geothermal power plant with Engineered Geothermal System (EGS) technology. The results showed that the optimized SENDDCT not only has better cooling performance during the daytime but also is a cost effective option for EGS geothermal power plants.

[1]  Liu Wei,et al.  Analytical and numerical investigation of the solar chimney power plant systems , 2006 .

[2]  Bo Xiao,et al.  Economic analysis of power generation from floating solar chimney power plant , 2009 .

[3]  Behdad Moghtaderi,et al.  An in-depth assessment of hybrid solar–geothermal power generation , 2013 .

[4]  Lihua Xie,et al.  Global optimization for overall HVAC systems––Part II problem solution and simulations , 2005 .

[5]  Hal Gurgenci,et al.  Numerical simulation of solar enhanced natural draft dry cooling towers , 2014 .

[6]  M. A. dos S. Bernardes,et al.  Thermal and technical analyses of solar chimneys , 2003 .

[7]  Eric Kozubal,et al.  A desiccant-enhanced evaporative air conditioner: Numerical model and experiments , 2013 .

[8]  T. W. von Backström,et al.  Cost Analysis of solar chimney power plants. , 2009 .

[9]  Richard Kirkham Ferry and Brandon's Cost Planning of Buildings , 2007 .

[10]  Eusiel Rubio-Castro,et al.  Optimization of mechanical draft counter flow wet-cooling towers using a rigorous model , 2011 .

[11]  Jinbo Wang,et al.  Novel concept for producing energy integrating a solar collector with a man made mountain hollow , 2009 .

[12]  Shyan-Shu Shieh,et al.  Discrete model-based operation of cooling tower based on statistical analysis , 2013 .

[13]  Fang Wang,et al.  Performance of solar chimney power plant in Qinghai-Tibet Plateau , 2010 .

[14]  Henrique A. Matos,et al.  Modeling of existing cooling towers in ASPEN PLUS using an equilibrium stage method , 2012 .

[15]  Xinping Zhou,et al.  A Novel Solar Thermal Power Plant with Floating Chimney Stiffened onto a Mountainside and Potential of the Power Generation in China's Deserts , 2009 .

[16]  Hal Gurgenci,et al.  Solar enhanced natural draft dry cooling tower for geothermal power applications , 2012 .

[17]  Lihua Xie,et al.  Global optimization for overall HVAC systems––Part I problem formulation and analysis , 2005 .

[18]  Jörg Schlaich,et al.  Sustainable Electricity Generation with Solar Updraft Towers , 2004 .

[19]  Tingzhen Ming,et al.  Chimney shape numerical study for solar chimney power generating systems , 2013 .

[20]  D. G. Kröger,et al.  Air-cooled heat exchangers and cooling towers , 2005 .

[21]  Leon R. Glicksman,et al.  Computer optimization of dry and wet/dry cooling tower systems for large fossil and nuclear power plants , 1979 .

[22]  Wei Liu,et al.  Numerical analysis of flow and heat transfer characteristics in solar chimney power plants with energy storage layer , 2008 .

[23]  Bo Xiao,et al.  Comparison of classical solar chimney power system and combined solar chimney system for power generation and seawater desalination , 2010 .

[24]  Detlev G. Kröger,et al.  Critical evaluation of solar chimney power plant performance , 2006 .

[25]  R. Chargui,et al.  Numerical simulation of a cooling tower coupled with heat pump system associated with single house using TRNSYS , 2013 .

[26]  Arturo Jiménez-Gutiérrez,et al.  MINLP optimization of mechanical draft counter flow wet-cooling towers , 2010 .

[27]  Edoardo Gianolio,et al.  Heat Transfer Coefficients and Pressure Drops for Air Coolers with Different Numbers of Rows Under Induced and Forced Draft , 1981 .

[28]  Suoying He,et al.  Pre-cooling with Munters media to improve the performance of Natural Draft Dry Cooling Towers , 2013 .

[29]  V. I. Hanby,et al.  System optimization for HVAC energy management using the robust evolutionary algorithm. , 2009 .

[30]  Ron Johnson,et al.  Effects of Village Power Quality on Fuel Consumption and Operating Expenses , 2008 .

[31]  Hal Gurgenci,et al.  Windbreak walls reverse the negative effect of crosswind in short natural draft dry cooling towers into a performance enhancement , 2013 .

[32]  Yuan Pan,et al.  Analysis of output power smoothing method of the solar chimney power generating system , 2013 .

[33]  Max Lu,et al.  Challenges for geothermal energy utilisation , 2008 .

[34]  Antonie Eduard Conradie Performance optimization of engineering systems with particular reference to dry-cooled power plants , 1995 .

[35]  Jason R. Picardo,et al.  The Merkel equation revisited: A novel method to compute the packed height of a cooling tower , 2012 .

[36]  Guoliang Xu,et al.  Numerical analysis on the performance of solar chimney power plant system , 2011 .

[37]  Mahmoud Bourouis,et al.  Performance optimization of solar driven small-cooled absorption–diffusion chiller working with light hydrocarbons , 2013 .

[38]  M. Goodarzi,et al.  Heat rejection enhancement in natural draft cooling tower using radiator-type windbreakers , 2013 .

[39]  Detlev G. Kröger,et al.  Performance optimization of dry-cooling systems for power plants through SQP methods , 1998 .

[40]  A. Bejan,et al.  Constructal solar chimney configuration , 2010 .

[41]  Kamel Hooman Dry cooling towers as condensers for geothermal power plants , 2010 .