THE EFFECT OF CONTROLLER DELAY ON BOX AND BLOCK TEST PERFORMANCE

Multifunctional prosthesis controllers have shown higher classification accuracies when EMG feature extraction and pattern recognition are performed on time windows of longer duration [1] (see figure 1). However, there is a limit to the time over which EMG data can be collected and analyzed before the delay causes the control of the prosthesis to become cumbersome. While no one has objectively examined the impact of controller delays on performance, the controller delay that can be present before prosthesis control degrades has been debated. Childress and Weir [2] believe that controller delays should be kept below 50 ms to ensure that these delays are imperceptible to the user. However, another group has stated that delays as large as 300 ms are not perceivable by the user [3-4] and, while they have not commented on the effect of these delays on performance, they have stated that a 300 ms delay is acceptable for control of a prosthesis.

[1]  Kevin Englehart,et al.  Continuous multifunction myoelectric control using pattern recognition , 2003 .

[2]  Kevin B. Englehart,et al.  A wavelet-based continuous classification scheme for multifunction myoelectric control , 2001, IEEE Transactions on Biomedical Engineering.

[3]  S. Medendorp,et al.  Low‐dose (7.5 mg) oral methotrexate reduces the rate of progression in chronic progressive multiple sclerosis , 1995, Annals of neurology.

[4]  V. Mathiowetz,et al.  Adult norms for the Box and Block Test of manual dexterity. , 1985, The American journal of occupational therapy : official publication of the American Occupational Therapy Association.

[5]  Kevin B. Englehart,et al.  A robust, real-time control scheme for multifunction myoelectric control , 2003, IEEE Transactions on Biomedical Engineering.

[6]  R. Hébert,et al.  Validation of the Box and Block Test as a measure of dexterity of elderly people: reliability, validity, and norms studies. , 1994, Archives of physical medicine and rehabilitation.

[7]  D. Goodkin,et al.  Upper extremity function in multiple sclerosis: improving assessment sensitivity with box-and-block and nine-hole peg tests. , 1988, Archives of physical medicine and rehabilitation.

[8]  James H. Cauraugh,et al.  Chronic stroke motor recovery: duration of active neuromuscular stimulation , 2003, Journal of the Neurological Sciences.

[9]  G Goodman,et al.  The effects of a short thumb opponens splint on hand function in cerebral palsy: a single-subject study. , 1991, The American journal of occupational therapy : official publication of the American Occupational Therapy Association.