Photogrammetric calibration of a stereo light microscope

Quantitative stereo light microscopy has been used in very rare cases to obtain geometric representations of microscopic objects. Although the instrument itself has limitations, most of them efficiently overcome by other 3D microscopes, it bears considerable advantages in observing and measuring dynamic scenes with multiple objects. The biggest asset of the stereo method is that the full 3D work space is imaged in one shot — a property which distinguishes stereo from all the scanning techniques in 3D microscopy. With the work presented in this paper, we contribute to making the stereo technique applicable to the numerous mensuration tasks in the microscopic domain, where its potential would be invaluable.

[1]  G. Kino,et al.  CHAPTER 4 – Phase Imaging , 1996 .

[2]  C. A. HART,et al.  Manual of Photogrammetry , 1947, Nature.

[3]  D. M. Shotton Electronic light microscopy : the principles and practice of video-enhanced contrast, digital intensified fluorescence, and confocal scanning light microscopy , 1993 .

[4]  Dean Brown,et al.  Decentering distortion of lenses , 1966 .

[5]  Gaudenz Danuser Stereo Light Microscope Calibration for 3D Submicron Vision , 1996 .

[6]  Alan C. Bovik,et al.  Shape description of biological objects via stereo light microscopy , 1990, IEEE Trans. Syst. Man Cybern..

[7]  Gaudenz Danuser,et al.  Quantitative stereo vision for the stereo light microscope: an attempt to provide control feedback for a nanorobot system , 1997 .

[8]  Karl-Rudolf Koch,et al.  Parameter estimation and hypothesis testing in linear models , 1988 .

[9]  G. Kino,et al.  Confocal Scanning Optical Microscopy and Related Imaging Systems , 1996 .

[10]  Philip E. Gill,et al.  Practical optimization , 1981 .

[11]  J. Pawley,et al.  Handbook of Biological Confocal Microscopy , 1990, Springer US.

[12]  W Galbraith Novel method for stereo imaging in light microscopy at high magnifications. , 1995, NeuroImage.

[13]  Hans J. Tiziani,et al.  Three-dimensional Topometry with Stereo Microscopes , 1997 .

[14]  W. Reeves Royal Microscopical Society , 1873, Nature.

[15]  Gaudenz Danuser,et al.  Calibration procedure for light-optical and scanning-electron stereo microscopy in micro- and nanorobotics , 1995, Electronic Imaging.

[16]  H. Tiziani Optical methods for precision measurements , 1989 .

[17]  M. J. Box Bias in Nonlinear Estimation , 1971 .

[18]  Alan Boyde,et al.  Novel Method for Stereo Imaging in Light Microscopy at High Magnifications , 1993, NeuroImage.

[19]  Hans J. Tiziani Optical methods for precision measurements , 1989 .

[20]  Z Jericević,et al.  Geometric correction of digital images using orthonormal decomposition , 1988, Journal of microscopy.

[21]  Hans J. Tiziani,et al.  Corneal topometry by fringe projection: limits and possibilities , 1996, Other Conferences.