Alternative pre-analytic sample handling techniques for glucose measurement in the absence of fluoride tubes in low resource settings

Introduction Sodium fluoride (NaF) tubes are the recommended tubes for glucose measurements, but these are expensive, have limited number of uses, and are not always available in low resource settings. Alternative sample handling techniques are thus needed. We compared glucose stability in samples collected in various tubes exposed to different pre-analytical conditions in Uganda. Methods Random (non-fasted) blood samples were drawn from nine healthy participants into NaF, Ethylenediaminetetraacetic acid (EDTA), and plain serum tubes. The samples were kept un-centrifuged or centrifuged with plasma or serum pipetted into aliquots, placed in cool box with ice or at room temperature and were stored in a permanent freezer after 0, 2, 6, 12 and 24 hours post blood draw before glucose analysis. Results Rapid decline in glucose concentrations was observed when compared to baseline in serum (declined to 64%) and EDTA-plasma (declined to 77%) after 6 hours when samples were un-centrifuged at room temperature whilst NaF-plasma was stable after 24 hours in the same condition. Un-centrifuged EDTA-plasma kept on ice was stable for up to 6 hours but serum was not stable (degraded to 92%) in the same conditions. Early centrifugation prevented glucose decline even at room temperature regardless of the primary tube used with serum, EDTA-plasma and NaF-plasma after 24 hours. Conclusion In low resource settings we recommend use of EDTA tubes placed in cool box with ice and analysed within 6 hours as an alternative to NaF tubes. Alternatively, immediate separation of blood with manual hand centrifuges will allow any tube to be used even in remote settings with no electricity.

[1]  R. Ogu,et al.  Comparing the Glucose Results by Glucometer and Laboratory Methods: A Prospective Hospital Based Study , 2018 .

[2]  S. Pastakia,et al.  Diabetes in sub-Saharan Africa – from policy to practice to progress: targeting the existing gaps for future care for diabetes , 2017, Diabetes, metabolic syndrome and obesity : targets and therapy.

[3]  G. Bonetti,et al.  Which sample tube should be used for routine glucose determination? , 2016, Primary care diabetes.

[4]  A. Hattersley,et al.  Preanalytical sample handling of venous blood: how to ensure your glucose measurement is accurate and reliable , 2013 .

[5]  A. Convit,et al.  Impact of Blood Sample Collection and Processing Methods on Glucose Levels in Community Outreach Studies , 2013, Journal of environmental and public health.

[6]  E. A. Frank,et al.  Blood Glucose Determination: Plasma or Serum? , 2012, Journal of clinical laboratory analysis.

[7]  C. Musarurwa,et al.  Evaluation of cost per test of clinical biochemistry tests at Parirenyatwa Central Hospital Laboratory, Harare, Zimbabwe. , 2011, The Central African journal of medicine.

[8]  E. Seeley,et al.  Rapid blood separation is superior to fluoride for preventing in vitro reductions in measured blood glucose concentration , 2009, Journal of Clinical Pathology.

[9]  C. Nwani,et al.  Stability of Serum/Plasma Glucose for the Diagnosis of Diabetes Mellitus , 2009 .

[10]  Brian W Smith,et al.  Stability of common biochemical analytes in serum gel tubes subjected to various storage temperatures and times pre-centrifugation , 2008, Annals of clinical biochemistry.

[11]  W. Waring,et al.  Glycolysis inhibitors negatively bias blood glucose measurements: potential impact on the reported prevalence of diabetes mellitus , 2006, Journal of Clinical Pathology.

[12]  I. Brandslund,et al.  Optimization of preanalytical conditions and analysis of plasma glucose. 1. Impact of the new WHO and ADA recommendations on diagnosis of diabetes mellitus. , 2001, Scandinavian journal of clinical and laboratory investigation.

[13]  M. Stahl, L. G. M. Jørgensen, P. Hyltoft Petersen, Optimization of preanalytical conditions and analysis of plasma glucose. 1. Impact of the new WHO and ADA recommendations on diagnosis of diabetes mellitus , 2001 .

[14]  R. Swaminathan,et al.  Effectiveness of sodium fluoride as a preservative of glucose in blood. , 1989, Clinical chemistry.

[15]  J. Ruiter,et al.  The Stability of Glucose in Serum , 1963 .