Diffraction optical tomography using a quantitative phase imaging unit.

A simple and practical method to measure three-dimensional (3-D) refractive index (RI) distributions of biological cells is presented. A common-path self-reference interferometry consisting of a compact set of polarizers is attached to a conventional inverted microscope equipped with a beam scanning unit, which can precisely measure multiple 2-D holograms of a sample with high phase stability for various illumination angles, from which accurate 3-D optical diffraction tomograms of the sample can be reconstructed. 3-D RI tomograms of nonbiological samples such as polystyrene microspheres, as well as biological samples including human red blood cells and breast cancer cells, are presented.

[1]  YongKeun Park,et al.  Profiling individual human red blood cells using common-path diffraction optical tomography , 2014, Scientific Reports.

[2]  YongKeun Park,et al.  Quantitative phase imaging unit. , 2014, Optics letters.

[3]  Youngchan Kim,et al.  Common-path diffraction optical tomography for investigation of three-dimensional structures and dynamics of biological cells. , 2014, Optics express.

[4]  B. Wattellier,et al.  Enhanced 3D spatial resolution in quantitative phase microscopy using spatially incoherent illumination. , 2014, Optics express.

[5]  Jing-Wei Su,et al.  Tomographic diffractive microscopy of living cells based on a common-path configuration. , 2014, Optics letters.

[6]  Joseph M. Martel,et al.  Three-Dimensional Holographic Refractive-Index Measurement of Continuously Flowing Cells in a Microfluidic Channel. , 2014, Physical review applied.

[7]  Jong Chul Ye,et al.  Real-time Visualization of 3-d Dynamic Microscopic Objects Using Optical Diffraction Tomography References and Links , 2022 .

[8]  P Memmolo,et al.  Digital holography as a method for 3D imaging and estimating the biovolume of motile cells. , 2013, Lab on a chip.

[9]  Jaeduck Jang,et al.  Spectro-refractometry of individual microscopic objects using swept-source quantitative phase imaging. , 2013, Analytical chemistry.

[10]  Samarendra K. Mohanty,et al.  Optical tweezers assisted quantitative phase imaging led to thickness mapping of red blood cells , 2013 .

[11]  YongKeun Park,et al.  High-resolution three-dimensional imaging of red blood cells parasitized by Plasmodium falciparum and in situ hemozoin crystals using optical diffraction tomography , 2013, Journal of biomedical optics.

[12]  YoungJu Jo,et al.  Quantitative Phase Imaging Techniques for the Study of Cell Pathophysiology: From Principles to Applications , 2013, Sensors.

[13]  P. Marquet,et al.  Marker-free phase nanoscopy , 2013, Nature Photonics.

[14]  Yongjin Sung,et al.  Stain-Free Quantification of Chromosomes in Live Cells Using Regularized Tomographic Phase Microscopy , 2012, PloS one.

[15]  Terry E. Moschandreou,et al.  Blood Cell - An Overview of Studies in Hematology , 2012 .

[16]  S. Jacques,et al.  Measurement of single cell refractive index, dry mass, volume, and density using a transillumination microscope. , 2012, Physical review letters.

[17]  Zahid Yaqoob,et al.  Single-shot quantitative dispersion phase microscopy. , 2012, Applied physics letters.

[18]  Subra Suresh,et al.  Optical measurement of biomechanical properties of individual erythrocytes from a sickle cell patient. , 2012, Acta biomaterialia.

[19]  Jaeduck Jang,et al.  Dynamic spectroscopic phase microscopy for quantifying hemoglobin concentration and dynamic membrane fluctuation in red blood cells. , 2012, Optics express.

[20]  Yizheng Zhu,et al.  Quantitative phase spectroscopy , 2012, Biomedical optics express.

[21]  Barry R. Masters,et al.  Quantitative Phase Imaging of Cells and Tissues , 2012 .

[22]  Zhuo Wang,et al.  Spatial light interference tomography (SLIT) , 2011, Optics express.

[23]  V. Tuchin,et al.  The refractive index of human hemoglobin in the visible range , 2011, Physics in medicine and biology.

[24]  Subra Suresh,et al.  Biophysics of Malarial Parasite Exit from Infected Erythrocytes , 2011, PloS one.

[25]  Huafeng Ding,et al.  Effective 3D viscoelasticity of red blood cells measured by diffraction phase microscopy , 2011, Biomedical optics express.

[26]  Yongjin Sung,et al.  Quantitative dispersion microscopy , 2010, Biomedical optics express.

[27]  Gabriel Popescu,et al.  Measurement of red blood cell mechanics during morphological changes , 2010, Proceedings of the National Academy of Sciences.

[28]  Nir S. Gov,et al.  Metabolic remodeling of the human red blood cell membrane , 2010, Proceedings of the National Academy of Sciences.

[29]  Natan T Shaked,et al.  Two-step-only phase-shifting interferometry with optimized detector bandwidth for microscopy of live cells. , 2009, Optics express.

[30]  Andreas Stemmer,et al.  Simplified approach to diffraction tomography in optical microscopy. , 2009, Optics express.

[31]  Christian Depeursinge,et al.  Submicrometer tomography of cells by multiple-wavelength digital holographic microscopy in reflection. , 2009, Optics letters.

[32]  C. Fang-Yen,et al.  Optical diffraction tomography for high resolution live cell imaging. , 2009, Optics express.

[33]  Colin J R Sheppard,et al.  Image formation in holographic tomography. , 2008, Optics letters.

[34]  Yongkeun Park,et al.  Refractive index maps and membrane dynamics of human red blood cells parasitized by Plasmodium falciparum , 2008, Proceedings of the National Academy of Sciences.

[35]  M. Friebel,et al.  Model function to calculate the refractive index of native hemoglobin in the wavelength range of 250-1100 nm dependent on concentration. , 2006, Applied optics.

[36]  E. Cuche,et al.  Cell refractive index tomography by digital holographic microscopy. , 2006, Optics letters.

[37]  E. Cuche,et al.  Measurement of the integral refractive index and dynamic cell morphometry of living cells with digital holographic microscopy. , 2005, Optics express.

[38]  V. Lauer New approach to optical diffraction tomography yielding a vector equation of diffraction tomography and a novel tomographic microscope , 2002, Journal of microscopy.

[39]  E. Cuche,et al.  Spatial filtering for zero-order and twin-image elimination in digital off-axis holography. , 2000, Applied optics.

[40]  E. Wolf Three-dimensional structure determination of semi-transparent objects from holographic data , 1969 .

[41]  R. Barer Interference Microscopy and Mass Determination , 1952, Nature.

[42]  M. Takeda,et al.  Fourier-transform method of fringe-pattern analysis for computer-based topography and interferometry , 1982 .