Analysis of the hazards for the molten cuprous chloride pouring operation in an industrial hydrogen production facility

An analysis is reported of a design for a local exhaust ventilation system for the molten cuprous chloride pouring station in an industrial plant. Heat recovery from molten cuprous chloride is a key process within the copper–chlorine (Cu–Cl) cycle of thermochemical water splitting for hydrogen production. Because of particulate matter, dust, and vapors emitted by the molten salt, an effective and safe design is crucial. The design process involves calculating duct diameters to provide the desired duct air velocity through the system. The static pressure is evaluated so that the fan size can be determined. An adequate supply of makeup air must be provided to replace the air exhausted through the ventilation system. The economics of the ventilation system and ways to protect employee health, as well as minimize the costs associated with exhaust ventilation, are also described. Copyright © 2011 John Wiley & Sons, Ltd.

[1]  H. J. McDermott Hand book of ventilation for contaminant control , 2014 .

[2]  G. Naterer,et al.  Comparison of molten salt heat recovery options in the Cu–Cl cycle of hydrogen production , 2011 .

[3]  Ibrahim Dincer,et al.  Heat recovery from molten CuCl in the Cu–Cl cycle of hydrogen production , 2010 .

[4]  Antonio Casimiro Caputo,et al.  Upgrading mixed ventilation systems in industrial conditioning , 2009 .

[5]  Ibrahim Dincer,et al.  Recent Canadian advances in nuclear-based hydrogen production and the thermochemical Cu–Cl cycle , 2009 .

[6]  Greg F. Naterer,et al.  Thermochemical hydrogen production with a copper-chlorine cycle. I: oxygen release from copper oxychloride decomposition , 2008 .

[7]  Jamil A. Khan,et al.  Effects of inlet and exhaust locations and emitted gas density on indoor air contaminant concentrations , 2006 .

[8]  藤雄 渡辺,et al.  減圧条件下での溶融飛灰からの亜鉛,鉛,銅の塩化揮発促進 , 2006 .

[9]  Xi Chen,et al.  Numerical Investigation on the Influence of Contaminant Source Location, Occupant Distribution and Air Distribution on Emergency Ventilation Strategy , 2005 .

[10]  Bin Zhao,et al.  Prediction of transient contaminant dispersion and ventilation performance using the concept of accessibility , 2004 .

[11]  Shengwei Wang,et al.  Application of CFD in retrofitting air-conditioning systems in industrial buildings , 2003 .

[12]  Kee-Chiang Chung,et al.  Effect of ventilation pattern on room air and contaminant distribution , 2001 .

[13]  Hannu Koskela,et al.  Classification for the room air conditioning strategies , 2000 .

[14]  I. Budaiwi,et al.  Impact of Combined Dilution and Pressurisation Effects of Ventilation Air on Indoor Contaminant Concentration , 1998, Indoor and Built Environment.

[15]  L. C. Wagner,et al.  A mass spectrometric study of the fragmentation of the cuprous chloride vapor system , 1974 .

[16]  G. Gigli,et al.  Dissociation Energy of CuCl and Cu2Cl2 Gaseous Molecules , 1972 .

[17]  G. Gigli,et al.  Mass Spectrometric Study of the Vaporization of Cuprous Chloride and the Dissociation Energy of Cu3Cl3, Cu4Cl4, and Cu5Cl5 , 1971 .

[18]  L. J. Cralley,et al.  Industrial Ventilation. A Manual of Recommended Practice (3rd ed.) , 1955 .

[19]  American Conference Of Governmental Industrial Hygienists 1998 Ventilation A O , 2019 .

[20]  J. Ángel,et al.  American Conference of Governmental Industrial Hygienists Committee on Industrial Ventilation (2013) Industrial Ventilation: A Manual of Recommended Practice for Design. , 2013 .

[21]  N. L. Lofgren The Thermodynamics of Gaseous, Cuprous Chloride Monomer and Trimer , 2010 .

[22]  Ilpo Kulmala,et al.  Local ventilation solution for large, warm emission sources. , 2007, The Annals of occupational hygiene.

[23]  B. Moshfegh,et al.  A study of Variable Air Volume ( VAV ) systems in foundries , 2007 .

[24]  C E Feigley,et al.  Comparison of mathematical models for exposure assessment with computational fluid dynamic simulation. , 2000, Applied occupational and environmental hygiene.

[25]  M. Sherman Tracer-gas techniques for measuring ventilation in a single zone , 1990 .