Linear over-modulation strategy for current control in photovoltaic inverter

Photovoltaic (PV) inverters autonomously adjust their DC-link voltages to maximize power generation. Around sunrise or sunset, a PV inverter may operate at much lower DC-link voltage than the nominal level due to the low irradiance. The inverter would be under over-modulation if the DC-link voltage is relatively low to the grid voltage at the point of common coupling. In this paper, a series of implementation schemes are proposed to keep the current regulation under over-modulation. After the proposed method is detailed, its fundamental operations are verified by a small-scale prototype inverter and further evaluated by the 250 kW PV inverter installed at a proving ground.

[1]  A. Zuccato,et al.  Integrated optimum control of quasi-direct converters , 1997 .

[2]  Seung-Ki Sul,et al.  A novel dynamic overmodulation strategy for fast torque control of high-saliency-ratio AC motor , 2005, IEEE Transactions on Industry Applications.

[3]  Danwei Wang,et al.  Relationship between space-vector modulation and three-phase carrier-based PWM: a comprehensive analysis [three-phase inverters] , 2002, IEEE Trans. Ind. Electron..

[4]  Ahmet M. Hava,et al.  Carrier-based PWM-VSI overmodulation strategies: analysis, comparison, and design , 1998 .

[5]  Seung-Ki Sul Design of Regulators for Electric Machines and Power Converters , 2011 .

[6]  Seung-Ki Sul,et al.  A novel dynamic overmodulation strategy for fast torque control of high-saliency-ratio AC motor , 2005, IEEE Transactions on Industry Applications.

[7]  Seung-Ki Sul,et al.  Overmodulation strategy for high performance torque control , 1996 .

[8]  Raymond Hanus,et al.  Anti-windup, bumpless, and conditioned transfer techniques for PID controllers , 1996 .

[9]  Frede Blaabjerg,et al.  Proportional-resonant controllers and filters for grid-connected voltage-source converters , 2006 .

[10]  Seung-Ki Sul,et al.  Asymmetric Control of DC-Link Voltages for Separate MPPTs in Three-Level Inverters , 2013, IEEE Transactions on Power Electronics.

[11]  Joachim Holtz,et al.  On continuous control of PWM inverters in the overmodulation range including the six-step mode , 1993 .

[12]  Seung-Ki Sul,et al.  Overmodulation strategy for high performance torque control , 1996, PESC Record. 27th Annual IEEE Power Electronics Specialists Conference.

[13]  Joachim Holtz,et al.  Compensated synchronous PI current controller in overmodulation range and six-step operation of space-vector-modulation-based vector-controlled drives , 2002, IEEE Trans. Ind. Electron..

[14]  T. Lipo,et al.  Dynamic overmodulation characteristics of triangle intersection PWM methods , 1997, IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting.

[15]  Seung-Ki Sul,et al.  Phase locked loop based on an observer for grid synchronization , 2013, 2013 Twenty-Eighth Annual IEEE Applied Power Electronics Conference and Exposition (APEC).

[16]  Robert D. Lorenz,et al.  One-step optimal space vector PWM current regulation using a neural network , 1994, Proceedings of 1994 IEEE Industry Applications Society Annual Meeting.