Effect of grid-connected DFIG wind turbines on power system transient stability

In some power systems, the penetration of wind power is increasing rapidly and starts to influence the overall system behavior and stability. Under this condition, it becomes necessary to require wind turbine generators (WTGs) to remain in service during grid faults to support network voltage and frequency. This paper investigates the effect of grid-connected wind turbines driving doubly-fed induction generators (DFIGs) on the transient stability of power systems. By using an uninterrupted operation scheme and the fast control of the DFIG converters, the DFIG wind turbines can successfully ride through grid faults and have no problem of angular stability associated with the conventional synchronous generators. Therefore, the integration of DFIG wind turbines can even bring some benefits on power system transient performance and stability. Simulation studies are carried out to demonstrate and compare the transient performance of the IEEE 10-machine 39-bus system with and without wind power integration during a severe grid fault. Results show that a better transient performance is achieved by the power system with wind power integration.

[1]  S. K. Salman,et al.  Windmill modelling consideration and factors influencing the stability of a grid-connected wind power based embedded generator , 2003, 2003 IEEE Power Engineering Society General Meeting (IEEE Cat. No.03CH37491).

[2]  T. Lipo,et al.  Vector Control and Dynamics of AC Drives , 1996 .

[3]  N.W. Miller,et al.  Dynamic modeling of GE 1.5 and 3.6 MW wind turbine-generators for stability simulations , 2003, 2003 IEEE Power Engineering Society General Meeting (IEEE Cat. No.03CH37491).

[4]  S. Salman,et al.  Windmill Modeling Consideration and Factors Influencing the Stability of a Grid-Connected Wind Power Based Embedded Generator , 2002, IEEE Power Engineering Review.

[5]  V. Akhmatov Analysis of Dynamic Behaviour of Electric Power Systems with Large Amount of Wind Power , 2003 .

[6]  S. K. Salman,et al.  Windmill modeling consideration and factors influencing the stability of a grid-connected wind power-based embedded generator , 2002 .

[7]  R.G. Harley,et al.  Real-Time Implementation of a STATCOM on a Wind Farm Equipped With Doubly Fed Induction Generators , 2006, IEEE Transactions on Industry Applications.

[8]  Mohammed H. Haque Damping improvement by FACTS devices: A comparison between STATCOM and SSSC , 2006 .

[9]  R. Podmore,et al.  A Practical Method for the Direct Analysis of Transient Stability , 1979, IEEE Transactions on Power Apparatus and Systems.

[10]  Jon Clare,et al.  Doubly fed induction generator using back-to-back PWM converters and its application to variable-speed wind-energy generation , 1996 .

[11]  M. Bruntt,et al.  Incorporation of wind power in the east Danish power system , 1999, PowerTech Budapest 99. Abstract Records. (Cat. No.99EX376).