Electrochemical transient techniques for the evaluation of reinforcement corrosion in concrete

A galvano static pulse technique has recently been developed which enables the transient electrochemical potential response of a corrosion interface to an applied current to be studied. The technique has shown some promise in determining the corrosion rate of steel in concrete in both the laboratory and in the field. However, this technique is less well known in the civil engineering community than other techniques and there are a number of pitfalls to be avoided in carrying out field measurements. This paper reports on the results of a series of galvanostatic pulse transient response measurements carried out to determine the optimummeasurement parameters for assessing corroding reinforcing steel in concrete. Measurements were conducted on bars, which were undergoing a range of corrosion rates, from passive steel to actively corroding steel. The duration of the applied galvanostatic pulse was varied from 5 s to 300 s and the sampling rate used to capture the transient response was also varied from 50 Hz to 10 kHz. The electrochemical potential transient response was analysed to obtain equivalent electronic components that comprise a series of capacitor and resistor pairs, whose values are dependent on the corrosion condition of the reinforcing steel. The corrosion rate was calculated from a summation of those separate resistive components, which could be identified as being associated with the corrosion interface. The selection of measurement parameters to give the most accurate assessment of corrosion rate of steel in concrete was discussed. Guidance is given on the use of the galvanostatic pulse transient technique to assess the corrosion rate of steel in concrete and for the interpretation of the data obtained.

[1]  Steve Millard,et al.  Use of galvanostatic pulse measurements on active reinforcing steel in concrete to assess corrosion rates , 2001 .

[2]  Carmen Andrade,et al.  Corrosion rate monitoring in the laboratory and on-site , 1996 .

[3]  A. Cobo,et al.  On-site determination of corrosion rate in reinforced concrete structures by use of galvanostatic pulses , 2001 .

[4]  J. M. Miranda,et al.  Considerations on reproducibility of potential and corrosion rate measurements in reinforced concrete , 2004 .

[5]  S. Sathiyanarayanan,et al.  Corrosion monitoring of steel in concrete by galvanostatic pulse technique , 2006 .

[6]  Carmen Andrade,et al.  On-site measurements of corrosion rate of reinforcements , 2001 .

[7]  J. Sykes,et al.  A GALVANOSTATIC PULSE TECHNIQUE FOR INVESTIGATION OF STEEL CORROSION IN CONCRETE , 1989 .

[8]  Gareth K. Glass,et al.  An assessment of the coulostatic method applied to the corrosion of steel in concrete , 1995 .

[9]  Steve Millard,et al.  Galvanostatic Pulse Measurements of Passive and Active Reinforcing Steel in Concrete , 2000 .

[10]  M. Stern,et al.  Electrochemical Polarization I . A Theoretical Analysis of the Shape of Polarization Curves , 1957 .

[11]  J. Randles Kinetics of rapid electrode reactions , 1947 .

[12]  Ns Berke,et al.  Techniques to Assess the Corrosion Activity of Steel Reinforced Concrete Structures , 1996 .

[13]  C. L. Page,et al.  An investigation of galvanostatic transient methods used to monitor the corrosion rate of steel in concrete , 1993 .

[14]  Steve Millard,et al.  ELECTROCHEMICAL TECHNIQUES FOR CORROSION ASSESSMENT OF REINFORCED CONCRETE STRUCTURES. , 1999 .

[15]  Howard W. Pickering,et al.  Electrochemical Measurements on Concrete Bridges for Evaluation of Reinforcement Corrosion Rates , 1993 .