Lower-limb multi-joint stiffness of knee and ankle

Lower-limb multi-joint (knee and ankle) stiffness may play an important role in functional activities such as walking, and may be significantly altered post stroke. Thus, determination of lower-limb multi joint stiffness matrix is important for better understanding of gait and of pathological changes post stroke. In this study, using novel dynamics decomposition, the knee and ankle joint stiffness matrix including cross-coupled stiffness terms between the two joints were determined and reported ever first. The determined stiffness matrix may be useful for gait studies, and can be served as a baseline for studying pathophysiological changes post stroke.

[1]  Tetsuro Muraoka,et al.  In vivo passive mechanical properties of the human gastrocnemius muscle belly. , 2005, Journal of biomechanics.

[2]  Symposium synopsis , 1986 .

[3]  Fan Gao,et al.  Altered contractile properties of the gastrocnemius muscle poststroke. , 2008, Journal of applied physiology.

[4]  E. Roth,et al.  Changes in Passive Properties of Hemiplegic nkles With Spastic , 2004 .

[5]  I W Hunter,et al.  System identification of human joint dynamics. , 1990, Critical reviews in biomedical engineering.

[6]  C. Richards,et al.  Contribution of passive stiffness to ankle plantarflexor moment during gait after stroke. , 2000, Archives of physical medicine and rehabilitation.

[7]  R. Young Spasticity: A review , 1994, Neurology.

[8]  Knee Recurvatum in Gait: A Study of Associated Knee Biomechanics , 1996 .

[9]  H. Kazerooni,et al.  Biomechanical design of the Berkeley lower extremity exoskeleton (BLEEX) , 2006, IEEE/ASME Transactions on Mechatronics.

[10]  Antony J. Hodgson,et al.  A model-independent definition of attractor behavior applicable to interactive tasks , 2000, IEEE Trans. Syst. Man Cybern. Part C.

[11]  Neville Hogan,et al.  The mechanics of multi-joint posture and movement control , 1985, Biological Cybernetics.

[12]  Peter Craven,et al.  Smoothing noisy data with spline functions , 1978 .

[13]  Li-Qun Zhang,et al.  Ultrasonic evaluations of Achilles tendon mechanical properties poststroke. , 2009, Journal of applied physiology.

[14]  Alfred D. Grant Gait Analysis: Normal and Pathological Function , 2010 .

[15]  K. Granata,et al.  Ankle and Knee Coupling in Patients with Spastic Diplegia: Effects of Gastrocnemius-Soleus Lengthening , 2002, The Journal of bone and joint surgery. American volume.

[16]  Fan Gao,et al.  In Vivo Evaluations of Morphologic Changes of Gastrocnemius Muscle Fascicles and Achilles Tendon in Children with Cerebral Palsy , 2011, American journal of physical medicine & rehabilitation.

[17]  Li Li,et al.  The function of gastrocnemius as a knee flexor at selected knee and ankle angles. , 2002, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[18]  J.J. Palazzolo,et al.  Stochastic Estimation of Arm Mechanical Impedance During Robotic Stroke Rehabilitation , 2007, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[19]  J. Mansour,et al.  The passive elastic moment at the hip. , 1982, Journal of biomechanics.

[20]  Yupeng Ren,et al.  Changes of calf muscle-tendon biomechanical properties induced by passive-stretching and active-movement training in children with cerebral palsy. , 2011, Journal of applied physiology.

[21]  M. Hallett,et al.  Classification and definition of disorders causing hypertonia in childhood. , 2003, Pediatrics.

[22]  G. Allison,et al.  Reflex and non-reflex elements of hypertonia in triceps surae muscles following acquired brain injury: implications for rehabilitation. , 2001, Disability and rehabilitation.

[23]  Li-Qun Zhang,et al.  Robust identification of multi-joint human arm impedance based on dynamics decomposition: A modeling study , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[24]  Pyung Hun Chang,et al.  Stochastic Estimation of Human Arm Impedance Using Robots With Nonlinear Frictions: An Experimental Validation , 2013, IEEE/ASME Transactions on Mechatronics.

[25]  R. Gorman,et al.  A new method for measuring passive length-tension properties of human gastrocnemius muscle in vivo. , 2005, Journal of biomechanics.

[26]  L. Zhang,et al.  Dynamic and static control of the human knee joint in abduction-adduction. , 2001, Journal of biomechanics.

[27]  Li-Qun Zhang,et al.  Position-dependent, hyperexcitable patellar reflex dynamics in chronic stroke. , 2013, Archives of physical medicine and rehabilitation.

[28]  R. Riener,et al.  Identification of passive elastic joint moments in the lower extremities. , 1999, Journal of biomechanics.

[29]  J. Perry Kinesiology of lower extremity bracing. , 1974, Clinical orthopaedics and related research.

[30]  Eric Berton,et al.  Determination of passive moment-angle relationships at the trapeziometacarpal joint. , 2010, Journal of biomechanical engineering.

[31]  W. Rymer,et al.  In vivo human knee joint dynamic properties as functions of muscle contraction and joint position. , 1997, Journal of biomechanics.

[32]  Li-Qun Zhang,et al.  Intelligent stretching of ankle joints with contracture/spasticity , 2002, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[33]  Fan Gao,et al.  Changes in passive mechanical properties of the gastrocnemius muscle at the muscle fascicle and joint levels in stroke survivors. , 2009, Archives of physical medicine and rehabilitation.

[34]  Pyung Hun Chang,et al.  Stochastic estimation of human arm impedance under nonlinear friction in robot joints: A model study , 2009, Journal of Neuroscience Methods.

[35]  A. Esquenazi,et al.  Common patterns of clinical motor dysfunction , 1997, Muscle & nerve. Supplement.

[36]  D. Bourbonnais,et al.  Weakness in patients with hemiparesis. , 1989, The American journal of occupational therapy : official publication of the American Occupational Therapy Association.

[37]  Hyung-Soon Park,et al.  Developing a Multi-Joint Upper Limb Exoskeleton Robot for Diagnosis, Therapy, and Outcome Evaluation in Neurorehabilitation , 2013, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[38]  Mark L. Nagurka,et al.  Dynamic and loaded impedance components in the maintenance of human arm posture , 1993, IEEE Trans. Syst. Man Cybern..