Free‐breathing whole‐heart coronary MRA with 3D radial SSFP and self‐navigated image reconstruction

Respiratory motion is a major source of artifacts in cardiac magnetic resonance imaging (MRI). Free‐breathing techniques with pencil‐beam navigators efficiently suppress respiratory motion and minimize the need for patient cooperation. However, the correlation between the measured navigator position and the actual position of the heart may be adversely affected by hysteretic effects, navigator position, and temporal delays between the navigators and the image acquisition. In addition, irregular breathing patterns during navigator‐gated scanning may result in low scan efficiency and prolonged scan time. The purpose of this study was to develop and implement a self‐navigated, free‐breathing, whole‐heart 3D coronary MRI technique that would overcome these shortcomings and improve the ease‐of‐use of coronary MRI. A signal synchronous with respiration was extracted directly from the echoes acquired for imaging, and the motion information was used for retrospective, rigid‐body, through‐plane motion correction. The images obtained from the self‐navigated reconstruction were compared with the results from conventional, prospective, pencil‐beam navigator tracking. Image quality was improved in phantom studies using self‐navigation, while equivalent results were obtained with both techniques in preliminary in vivo studies. Magn Reson Med 54:476–480, 2005. © 2005 Wiley‐Liss, Inc.

[1]  O Dössel,et al.  Fast isotropic volumetric coronary MR angiography using free‐breathing 3D radial balanced FFE acquisition , 2004, Magnetic resonance in medicine.

[2]  Andrew C Larson,et al.  Self‐gated cardiac cine MRI , 2004, Magnetic resonance in medicine.

[3]  René M. Botnar,et al.  “Soap‐Bubble” visualization and quantitative analysis of 3D coronary magnetic resonance angiograms , 2002, Magnetic resonance in medicine.

[4]  Walter F Block,et al.  Time‐resolved contrast‐enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory , 2002, Magnetic resonance in medicine.

[5]  René M. Botnar,et al.  Impact of navigator timing on free‐breathing submillimeter 3D coronary magnetic resonance angiography , 2002, Magnetic resonance in medicine.

[6]  P. Börnert,et al.  Free-breathing cardiac MR imaging: study of implications of respiratory motion--initial results. , 2001, Radiology.

[7]  A Shankaranarayanan,et al.  Two‐step navigatorless correction algorithm for radial k‐space MRI acquisitions , 2001, Magnetic resonance in medicine.

[8]  A. Manduca,et al.  Autocorrection in MR imaging: adaptive motion correction without navigator echoes. , 2000, Radiology.

[9]  Todd S. Sachs,et al.  The real-time interactive 3-D-DVA for robust coronary MRA , 2000, IEEE Transactions on Medical Imaging.

[10]  René M. Botnar,et al.  Low-cost MR-compatible moving heart phantom. , 2000, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[11]  J. Pipe Motion correction with PROPELLER MRI: Application to head motion and free‐breathing cardiac imaging , 1999, Magnetic resonance in medicine.

[12]  René M. Botnar,et al.  Submillimeter three-dimensional coronary MR angiography with real-time navigator correction: comparison of navigator locations. , 1999, Radiology.

[13]  V Rasche,et al.  Motion compensated projection reconstruction , 1999, Magnetic resonance in medicine.

[14]  J. Pipe,et al.  Sampling density compensation in MRI: Rationale and an iterative numerical solution , 1999, Magnetic resonance in medicine.

[15]  S. Riederer,et al.  Respiratory Motion of the Heart: Kinematics and the Implications for the Spatial Resolution in Coronary Imaging , 1995, Magnetic resonance in medicine.

[16]  Sam T. S. Wong,et al.  A strategy for sampling on a sphere applied to 3D selective RF pulse design , 1994, Magnetic resonance in medicine.

[17]  G H Glover,et al.  Projection Reconstruction Techniques for Reduction of Motion Effects in MRI , 1992, Magnetic resonance in medicine.

[18]  Z H Cho,et al.  Extraction of cardiac and respiratory motion cycles by use of projection data and its applications to nmr imaging , 1990, Magnetic resonance in medicine.

[19]  J. Felmlee,et al.  Adaptive technique for high-definition MR imaging of moving structures. , 1989, Radiology.