Nanosecond fluorescence microscopy of single cells

A microscope based time-correlated single photon counting instrument has been used to measure nanosecond fluorescence decays from single cells. The excitation source for the instrument is a frequency doubled train of picosecond pulses from the cavity dumped output of a synchronously pumped dye laser. The dye laser is pumped by a mode-locked argon ion laser. In the microscope, the sample is excited and the emission collected using epi-illumination optics before being transmitted through an adjustable diaphragm, which can be closed to 10 μm in diameter. A Hamamatsu R928 photomultiplier is used to collect the fluorescence which is then analyzed using a non-linear least squares procedure. The microscope has been used to measure the intensity decays of model probes to determine the instrument performance and sensitivity. In addition, intensity and anisotropy decays collected from fura-2 loaded into single adherent rat basophilic leukemia cells were measured to demonstrate that the nanosecond fluorescence microscope can be used to obtain information about the environment and mobility of fluorescent probes in single cells.

[1]  M. Pleil,et al.  Primary scintillant fluorescent decay times in binary and ternary scintillators by near UV pulsed laser excitation , 1987 .

[2]  R. Dale,et al.  Rotational relaxation of the "microviscosity" probe diphenylhexatriene in paraffin oil and egg lecithin vesicles. , 1977, The Journal of biological chemistry.

[3]  A. Visser,et al.  Application of a reference convolution method to tryptophan fluorescence in proteins. A refined description of rotational dynamics. , 1987, European journal of biochemistry.

[4]  D. Axelrod Carbocyanine dye orientation in red cell membrane studied by microscopic fluorescence polarization. , 1979, Biophysical journal.

[5]  E Gratton,et al.  Phase fluorometric method for determination of standard lifetimes. , 1988, Analytical chemistry.

[6]  J. Lakowicz,et al.  Correction of timing errors in photomultiplier tubes used in phase-modulation fluorometry. , 1981, Journal of biochemical and biophysical methods.

[7]  T. Wensel,et al.  Nanosecond fluorescence microscopy. Emission kinetics of fura-2 in single cells. , 1991, Biophysical journal.

[8]  S. Baylor,et al.  Myoplasmic binding of fura-2 investigated by steady-state fluorescence and absorbance measurements. , 1988, Biophysical journal.

[9]  Michael Zuker,et al.  Delta function convolution method (DFCM) for fluorescence decay experiments , 1985 .

[10]  K. Kinosita,et al.  Dynamic structure of lipid bilayers studied by nanosecond fluorescence techniques. , 1977, Biochemistry.

[11]  M. Rodgers,et al.  INSTRUMENTATION FOR FLUORESCENCE MICROSCOPY WITH PICOSECOND TIME RESOLUTION , 1985, Photochemistry and photobiology.

[12]  D. Marquardt An Algorithm for Least-Squares Estimation of Nonlinear Parameters , 1963 .

[13]  J. Penn,et al.  Evaluation of single-photon-counting measurements of excited-state lifetimes. , 1982, Proceedings of the National Academy of Sciences of the United States of America.

[14]  R. Ramponi,et al.  An automatic pulsed laser microfluorometer with high spatial and temporal resolution , 1984, Journal of microscopy.

[15]  R. Tsien,et al.  A new generation of Ca2+ indicators with greatly improved fluorescence properties. , 1985, The Journal of biological chemistry.

[16]  C. G. Morgan,et al.  A single-photon-counting Fourier transform microfluorometer , 1986 .