Application of FRA polar plot technique to diagnose internal faults in power transformers

Frequency response analysis (FRA) technique has become a popular and reliable diagnostic tool in detecting various winding deformation in power transformers. Although the popularity of FRA is growing rapidly, interpretation of FRA signature requires high expertise. While all frequency response analyzers currently used for FRA signature measurement are capable in plotting both magnitude and angle of either the transfer function or impedance of each transformer winding, only magnitude is used for fault identification and quantification. This paper presents a new technique for FRA signature interpretation. The proposed technique relies on incorporating both magnitude and angle of the FRA signature in one polar plot. Results show that, polar plot is more capable in identifying and quantifying faults within power transformer than using only the magnitude of FRA signature. The proposed technique is easy to implement in any frequency response analyzer.

[1]  Dean Sharafi Life Extension of a Group of Western Power Transformers , 2010, 2010 Asia-Pacific Power and Energy Engineering Conference.

[2]  Jong-Ho Sun,et al.  Study on the On-line PD Measurement Technology for Power Transformer , 2006, 2006 IEEE 8th International Conference on Properties & applications of Dielectric Materials.

[3]  Luo Yongfen,et al.  Research on extraction technique of transformer core fundamental frequency vibration based on OLCM , 2006, IEEE Transactions on Power Delivery.

[4]  Z.D. Wang,et al.  Investigations on sensitivity of FRA technique in diagnosis of transformer winding deformations , 2004, Conference Record of the 2004 IEEE International Symposium on Electrical Insulation.

[5]  K. Feser,et al.  Transfer Function Method to Diagnose Axial Displacement and Radial Deformation of Transformer Winding , 2002, IEEE Power Engineering Review.

[6]  E. J. Figueroa MANAGING AN AGING FLEET OF TRANSFORMERS , 2009 .

[7]  Gerard Ledwich,et al.  Identification of high frequency transformer equivalent circuit using Matlab from frequency domain data , 1997, IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting.

[8]  Ma Weiping,et al.  Research on the influence of microorganism on tan /spl delta/ of power transformer oil , 2001, Proceedings of 2001 International Symposium on Electrical Insulating Materials (ISEIM 2001). 2001 Asian Conference on Electrical Insulating Diagnosis (ACEID 2001). 33rd Symposium on Electrical and Ele.

[9]  Syed Islam Detection of shorted turns and winding movements in large power transformers using frequency response analysis , 2000, 2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077).

[10]  S. V. Kulkarni,et al.  Analysis of Buckling Strength of Inner Windings in Transformers Under Radial Short-Circuit Forces , 2014, IEEE Transactions on Power Delivery.

[11]  Zhongdong Wang,et al.  Interpretation of Transformer FRA Responses— Part II: Influence of Transformer Structure , 2010, IEEE Transactions on Power Delivery.

[12]  Wensheng Gao,et al.  Deformation analysis of transformer winding by structure parameter , 2003, Proceedings of the 7th International Conference on Properties and Applications of Dielectric Materials (Cat. No.03CH37417).

[13]  N. Abeywickrama,et al.  Effect of Core Magnetization on Frequency Response Analysis (FRA) of Power Transformers , 2008, IEEE Transactions on Power Delivery.

[14]  Z.D. Wang,et al.  Winding movement in power transformers: a comparison of FRA measurement connection methods , 2006, IEEE Transactions on Dielectrics and Electrical Insulation.

[15]  A. Abu-Siada,et al.  Understanding power transformer frequency response analysis signatures , 2013, IEEE Electrical Insulation Magazine.

[16]  E. Billig,et al.  Mechanical stresses in transformer windings , 1946 .

[17]  R. Siregar,et al.  Thermal monitoring on power transformers , 2008, 2008 International Conference on Condition Monitoring and Diagnosis.

[18]  L. M. Geldenhuis Power transformer life management , 2005 .

[19]  Stefan Tenbohlen,et al.  Experimental and theoretical investigation of disc space variation in real high-voltage windings using transfer function method , 2010 .

[20]  A. Abu-Siada,et al.  A novel algorithm to detect internal transformer faults , 2011, 2011 IEEE Power and Energy Society General Meeting.

[21]  A. Kunakorn,et al.  Internal failure analysis of transformer windings , 2012, 2012 International Conference on High Voltage Engineering and Application.

[22]  Ma Weiping,et al.  Notice of RetractionResearch on the influence of microorganism on TAN δ of power transformer oil , 2011, 2011 IEEE Power Engineering and Automation Conference.