A Protein Concentration Measurement System Using a Flexural Plate-Wave Frequency-Shift Readout Technique

A protein concentration measurement system with two-port flexural plate-wave (FPW) biosensors using a frequency-shift readout technique is presented in this paper. The proposed frequency-shift readout method employs a peak detecting scheme to measure the amount of resonant frequency shift. The proposed system is composed of a linear frequency generator, a pair of peak detectors, two registers, and a subtractor. The frequency sweep range of the linear frequency generator is limited to 2 MHz to 10 MHz according to the characteristics of the FPW biosensors. The proposed frequency-shift readout circuit is carried out on silicon using a standard 0.18 μm CMOS technology. The sensitivity of the peak detectors is measured to be 10 mV. The power consumption of the proposed protein concentration measurement system is 48 mW given a 0.1 MHz system clock.

[1]  G. Kuchel,et al.  ELISA and multiplex technologies for cytokine measurement in inflammation and aging research. , 2008, The journals of gerontology. Series A, Biological sciences and medical sciences.

[2]  H. S. Wolff,et al.  iRun: Horizontal and Vertical Shape of a Region-Based Graph Compression , 2022, Sensors.

[3]  Behzad Razavi,et al.  Principles of Data Conversion System Design , 1994 .

[4]  Klaus J. Erb,et al.  Helminths, allergic disorders and IgE‐mediated immune responses: Where do we stand? , 2007, European journal of immunology.

[5]  I. Huang,et al.  Development of a FPW allergy biosensor for human IgE detection by MEMS and cystamine-based SAM technologies , 2008 .

[6]  Zhao Li,et al.  Self-assembled monolayer of ammonium pyrrolidine dithiocarbamate on copper detected using electrochemical methods, surface enhanced Raman scattering and quantum chemistry calculations , 2011 .

[7]  J. A. De Lima A linearly-tunable OTA-C sinusoidal oscillator for low-voltage applications , 2002 .

[8]  E. Storni,et al.  Evaluation of LIAISON Treponema Screen, a Novel Recombinant Antigen-Based Chemiluminescence Immunoassay for Laboratory Diagnosis of Syphilis , 2005, Clinical Diagnostic Laboratory Immunology.

[9]  F. Chew,et al.  Piezoelectric quartz crystal based label-free analysis for allergy disease. , 2000, Biosensors & bioelectronics.

[10]  J. Wei,et al.  Low temperature Cu-Cu thermo-compression bonding with temporary passivation of self-assembled monolayer and its bond strength enhancement , 2012, Microelectron. Reliab..

[11]  Colin M. Fitzsimmons,et al.  Factors Affecting Human IgE and IgG Responses to Allergen-Like Schistosoma mansoni Antigens: Molecular Structure and Patterns of in vivo Exposure , 2006, International Archives of Allergy and Immunology.

[12]  Rodolfo J. Romañach,et al.  Atomic force measurements of 16-mercaptohexadecanoic acid and its salt with CH , 2005 .

[13]  Meng-Yen Tsai,et al.  Preconditioning Gold Substrates Influences Organothiol Self-assembled Monolayer (SAM) Formation. , 2001, Journal of colloid and interface science.

[14]  Jian Zhang,et al.  Comparison of surface plasmon resonance spectroscopy and quartz crystal microbalance for human IgE quantification , 2004 .

[15]  Fred R. Beyette,et al.  Point-of-Care Technologies for Health Care , 2011, IEEE Transactions on Biomedical Engineering.

[16]  I-Yu Huang,et al.  Development of a Novel Flexural Plate Wave Biosensor for Immunoglobulin-E Detection by Using SAM and MEMS Technologies , 2006, 2006 5th IEEE Conference on Sensors.

[17]  Rasim Guldiken,et al.  Surface Modification on Acoustic Wave Biosensors for Enhanced Specificity , 2012, Sensors.

[18]  H Beutel,et al.  Development of a biosensor for E. coli based on a flexural plate wave (FPW) transducer. , 1998, Biosensors & bioelectronics.

[19]  Stephen J. Martin,et al.  Acoustic Wave Sensors: Theory, Design and Physico-Chemical Applications , 1996 .

[20]  Claudio Bianchini,et al.  Confined electrodeposition using a template-assisted procedure based on the selective desorption of a short chain thiol from a binary self-assembled monolayer formed on Ag( 1 1 1) , 2010 .

[21]  R. Lequin Enzyme immunoassay (EIA)/enzyme-linked immunosorbent assay (ELISA). , 2005, Clinical chemistry.

[22]  M. Aulice Scibioh,et al.  Single-wall carbon nanotube chemical attachment at platinum electrodes , 2010 .

[23]  David Fear,et al.  The biology of IGE and the basis of allergic disease. , 2001, Annual review of immunology.

[24]  David S. Ballantine,et al.  Acoustic wave sensors : theory, design, and physico-chemical applications , 1997 .

[25]  K. F. Tsang,et al.  A zero configured HomeCare gateway using ZigBee , 2011, 2011 IEEE International Conference on Consumer Electronics (ICCE).

[26]  Charlotte A. Gaydos,et al.  Using a Rapid Communication Approach to Improve a POC Chlamydia Test , 2011, IEEE Transactions on Biomedical Engineering.

[27]  Wen-Yang Chang,et al.  Phase Detection of the Two-port FPW Sensor for Biosensing , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[28]  S N Njau,et al.  Adult sudden death caused by aspiration of chewing gum. , 2004, Forensic science international.

[29]  P. Cazenave,et al.  Total and functional parasite specific IgE responses in Plasmodium falciparum-infected patients exhibiting different clinical status , 2007, Malaria Journal.

[30]  Kenzo Maehashi,et al.  Label-Free Electrical Detection Using Carbon Nanotube-Based Biosensors , 2009, Sensors.