Proteomics on an Orbitrap Benchtop Mass Spectrometer Using All-ion Fragmentation

The orbitrap mass analyzer combines high sensitivity, high resolution, and high mass accuracy in a compact format. In proteomics applications, it is used in a hybrid configuration with a linear ion trap (LTQ-Orbitrap) where the linear trap quadrupole (LTQ) accumulates, isolates, and fragments peptide ions. Alternatively, isolated ions can be fragmented by higher energy collisional dissociation. A recently introduced stand-alone orbitrap analyzer (Exactive) also features a higher energy collisional dissociation cell but cannot isolate ions. Here we report that this instrument can efficiently characterize protein mixtures by alternating MS and “all-ion fragmentation” (AIF) MS/MS scans in a manner similar to that previously described for quadrupole time-of-flight instruments. We applied the peak recognition algorithms of the MaxQuant software at both the precursor and product ion levels. Assignment of fragment ions to co-eluting precursor ions was facilitated by high resolution (100,000 at m/z 200) and high mass accuracy. For efficient fragmentation of different mass precursors, we implemented a stepped collision energy procedure with cumulative MS readout. AIF on the Exactive identified 45 of 48 proteins in an equimolar protein standard mixture and all of them when using a small database. The technique also identified proteins with more than 100-fold abundance differences in a high dynamic range standard. When applied to protein identification in gel slices, AIF unambiguously characterized an immunoprecipitated protein that was barely visible by Coomassie staining and quantified it relative to contaminating proteins. AIF on a benchtop orbitrap instrument is therefore an attractive technology for a wide range of proteomics analyses.

[1]  M. Mann,et al.  Quantitative proteomics reveals subset-specific viral recognition in dendritic cells. , 2010, Immunity.

[2]  M. Mann Comparative analysis to guide quality improvements in proteomics , 2009, Nature Methods.

[3]  R. Aebersold,et al.  Proteome-wide cellular protein concentrations of the human pathogen Leptospira interrogans , 2009, Nature.

[4]  Robert E. Kearney,et al.  A HUPO test sample study reveals common problems in mass spectrometry-based proteomics , 2009, Nature Methods.

[5]  Jürgen Cox,et al.  Computational principles of determining and improving mass precision and accuracy for proteome measurements in an Orbitrap , 2009, Journal of the American Society for Mass Spectrometry.

[6]  M. Gorenstein,et al.  The detection, correlation, and comparison of peptide precursor and product ions from data independent LC‐MS with data dependant LC‐MS/MS , 2009, Proteomics.

[7]  Dan Golick,et al.  Database searching and accounting of multiplexed precursor and product ion spectra from the data independent analysis of simple and complex peptide mixtures , 2009, Proteomics.

[8]  Jürgen Cox,et al.  A practical guide to the MaxQuant computational platform for SILAC-based quantitative proteomics , 2009, Nature Protocols.

[9]  M. Mann,et al.  MaxQuant enables high peptide identification rates, individualized p.p.b.-range mass accuracies and proteome-wide protein quantification , 2008, Nature Biotechnology.

[10]  M. Mann,et al.  Comprehensive mass-spectrometry-based proteome quantification of haploid versus diploid yeast , 2008, Nature.

[11]  M. Mann,et al.  Higher-energy C-trap dissociation for peptide modification analysis , 2007, Nature Methods.

[12]  A. Chakraborty,et al.  Use of an integrated MS--multiplexed MS/MS data acquisition strategy for high-coverage peptide mapping studies. , 2007, Rapid communications in mass spectrometry : RCM.

[13]  M. Mann,et al.  In-gel digestion for mass spectrometric characterization of proteins and proteomes , 2006, Nature Protocols.

[14]  A. Makarov,et al.  Orbitrap Mass Analyzer – Overview and Applications in Proteomics , 2006, Proteomics.

[15]  Xudong Yao,et al.  Tandem parallel fragmentation of peptides for mass spectrometry. , 2006, Analytical chemistry.

[16]  A. Makarov,et al.  Performance evaluation of a hybrid linear ion trap/orbitrap mass spectrometer. , 2006, Analytical chemistry.

[17]  M. Gorenstein,et al.  Simultaneous Qualitative and Quantitative Analysis of theEscherichia coli Proteome , 2006, Molecular & Cellular Proteomics.

[18]  Alexander Makarov,et al.  Orbitrap Mass Analyzer - Overview and Applications , 2006 .

[19]  M. Gorenstein,et al.  Quantitative proteomic analysis by accurate mass retention time pairs. , 2005, Analytical chemistry.

[20]  John D. Venable,et al.  Automated approach for quantitative analysis of complex peptide mixtures from tandem mass spectra , 2004, Nature Methods.

[21]  Jon D. Williams,et al.  Using accurate mass electrospray ionization-time-of-flight mass spectrometry with in-source collision-induced dissociation to sequence peptide mixtures. , 2003, Journal of chromatography. A.

[22]  Takamitsu Sasaki,et al.  Protein identification by peptide mass fingerprinting and peptide sequence tagging with alternating scans of nano-liquid chromatography/infrared multiphoton dissociation Fourier transform ion cyclotron resonance mass spectrometry. , 2003, Journal of mass spectrometry : JMS.

[23]  D. Goodlett,et al.  Shotgun collision‐induced dissociation of peptides using a time of flight mass analyzer , 2003, Proteomics.

[24]  R. Aebersold,et al.  Mass spectrometry-based proteomics , 2003, Nature.

[25]  A. Makarov,et al.  Interfacing the orbitrap mass analyzer to an electrospray ion source. , 2003, Analytical chemistry.

[26]  M. Mann,et al.  Stop and go extraction tips for matrix-assisted laser desorption/ionization, nanoelectrospray, and LC/MS sample pretreatment in proteomics. , 2003, Analytical chemistry.

[27]  J. Langridge,et al.  A novel precursor ion discovery method on a hybrid quadrupole orthogonal acceleration time-of-flight (Q-TOF) mass spectrometer for studying protein phosphorylation , 2002, Journal of the American Society for Mass Spectrometry.

[28]  M. Mann,et al.  Stable Isotope Labeling by Amino Acids in Cell Culture, SILAC, as a Simple and Accurate Approach to Expression Proteomics* , 2002, Molecular & Cellular Proteomics.

[29]  J. Yates,et al.  Large-scale analysis of the yeast proteome by multidimensional protein identification technology , 2001, Nature Biotechnology.

[30]  Makarov,et al.  Electrostatic axially harmonic orbital trapping: a high-performance technique of mass analysis , 2000, Analytical chemistry.

[31]  G. Neubauer,et al.  Parent ion scans of unseparated peptide mixtures. , 1996, Analytical chemistry.

[32]  M F Bean,et al.  Collisional fragmentation of glycopeptides by electrospray ionization LC/MS and LC/MS/MS: methods for selective detection of glycopeptides in protein digests. , 1993, Analytical chemistry.

[33]  B. Geiger A 130K protein from chicken gizzard: Its localization at the termini of microfilament bundles in cultured chicken cells , 1979, Cell.