2 The Measurement Process : MR Data Collection and Image Analysis

The subject is positioned on the scanner couch by the radiographer (technologist). The subject should be comfortable, to reduce movement during the scan as much as possible. The radiographer should use their insight into the subject’s emotional state to reduce anxiety if necessary; preparation on a separate couch may be helpful. A cushion under the knees can reduce cramp. Occasionally it is desirable to place the subject prone. Prone positioning of the head may be more comfortable if support is provided for the forehead and cheekbones, leaving a gap for the nose, as used in a massage table. Movement of the body can cause a head movement; a nasal positioning device (Tofts et al., 1990) can help cooperative subjects to keep still. Some patients will find it hard to keep still because of their disease. Study investigators are usually motivated to keep very still. Some

[1]  J. Dehmeshki,et al.  The normal appearing grey matter in primary progressive multiple sclerosis , 2003, Journal of Neurology.

[2]  John Suckling,et al.  A computational morphometric MRI study of schizophrenia: effects of hallucinations. , 2002, Cerebral cortex.

[3]  Gareth J. Barker,et al.  Classification of disease subgroup and correlation with disease severity using magnetic resonance imaging whole-brain histograms: application to magnetization transfer ratios and multiple sclerosis , 2002, IEEE Transactions on Medical Imaging.

[4]  M. Giger,et al.  Breast cancer: effectiveness of computer-aided diagnosis observer study with independent database of mammograms. , 2002, Radiology.

[5]  David H. Miller,et al.  Application of the new McDonald criteria to patients with clinically isolated syndromes suggestive of multiple sclerosis , 2002, Annals of neurology.

[6]  Laura M Parkes,et al.  Improved accuracy of human cerebral blood perfusion measurements using arterial spin labeling: Accounting for capillary water permeability , 2002, Magnetic resonance in medicine.

[7]  K. Uğurbil,et al.  Different excitation and reception distributions with a single‐loop transmit‐receive surface coil near a head‐sized spherical phantom at 300 MHz , 2002, Magnetic resonance in medicine.

[8]  Robert Turner,et al.  Image Distortion Correction in fMRI: A Quantitative Evaluation , 2002, NeuroImage.

[9]  Massimo Filippi,et al.  MRI techniques to monitor MS evolution: The present and the future , 2002, Neurology.

[10]  Nick C Fox,et al.  Mapping the evolution of regional atrophy in Alzheimer's disease: Unbiased analysis of fluid-registered serial MRI , 2002, Proceedings of the National Academy of Sciences of the United States of America.

[11]  R Turner,et al.  RF inhomogeneity compensation in structural brain imaging , 2002, Magnetic resonance in medicine.

[12]  A J Thompson,et al.  Brain atrophy in clinically early relapsing-remitting multiple sclerosis. , 2002, Brain : a journal of neurology.

[13]  David H. Miller,et al.  ADC mapping of the human optic nerve: Increased resolution, coverage, and reliability with CSF‐suppressed ZOOM‐EPI , 2002, Magnetic resonance in medicine.

[14]  À. Rovira,et al.  Isolated demyelinating syndromes: comparison of CSF oligoclonal bands and different MR imaging criteria to predict conversion to CDMS , 2001, Multiple sclerosis.

[15]  T. Ibrahim,et al.  Effect of RF coil excitation on field inhomogeneity at ultra high fields: a field optimized TEM resonator. , 2001, Magnetic resonance imaging.

[16]  M Cercignani,et al.  Segmenting brain white matter, gray matter and cerebro-spinal fluid using diffusion tensor-MRI derived indices. , 2001, Magnetic resonance imaging.

[17]  M Rovaris,et al.  Correlation of multiple sclerosis measures derived from T2-weighted, T1-weighted, magnetization transfer, and diffusion tensor MR imaging. , 2001, AJNR. American journal of neuroradiology.

[18]  J. Dehmeshki,et al.  Analysis of MTR histograms in multiple sclerosis using principal components and multiple discriminant analysis , 2001, Magnetic resonance in medicine.

[19]  M Alecci,et al.  Radio frequency magnetic field mapping of a 3 Tesla birdcage coil: Experimental and theoretical dependence on sample properties , 2001, Magnetic resonance in medicine.

[20]  M. Fernández-Seara,et al.  Trabecular bone volume fraction mapping by low‐resolution MRI , 2001, Magnetic resonance in medicine.

[21]  Karl J. Friston,et al.  A Voxel-Based Morphometric Study of Ageing in 465 Normal Adult Human Brains , 2001, NeuroImage.

[22]  C. Mainero,et al.  Correlates of MS disability assessed in vivo using aggregates of MR quantities , 2001, Neurology.

[23]  G J Barker,et al.  Neuropathological abnormalities in schizophrenia: evidence from magnetization transfer imaging. , 2001, Brain : a journal of neurology.

[24]  G J Parker,et al.  Accurate multislice gradient echo T1 measurement in the presence of non‐ideal RF pulse shape and RF field nonuniformity , 2001, Magnetic resonance in medicine.

[25]  Michael B. Smith,et al.  Signal‐to‐noise ratio and absorbed power as functions of main magnetic field strength, and definition of “90°” RF pulse for the head in the birdcage coil , 2001, Magnetic resonance in medicine.

[26]  N. Tubridy,et al.  Neuroradiological history: Sir Joseph Larmor and the basis of MRI physics , 2000, Neuroradiology.

[27]  Peter Jezzard,et al.  Physical basis of spatial distortions in magnetic resonance images , 2000 .

[28]  D. Hoult The principle of reciprocity in signal strength calculations—a mathematical guide , 2000 .

[29]  J. Hobart,et al.  Kurtzke scales revisited: the application of psychometric methods to clinical intuition. , 2000, Brain : a journal of neurology.

[30]  À. Rovira,et al.  Isolated demyelinating syndromes: comparison of different MR imaging criteria to predict conversion to clinically definite multiple sclerosis. , 2000, AJNR. American journal of neuroradiology.

[31]  J. Fischer,et al.  Intrarater and interrater reliability of the MS functional composite outcome measure , 2000, Neurology.

[32]  T Tolxdorff,et al.  Histogram‐based characterization of healthy and ischemic brain tissues using multiparametric MR imaging including apparent diffusion coefficient maps and relaxometry , 2000, Magnetic resonance in medicine.

[33]  Correction for B(1) and B(0) variations in quantitative T(2) measurements using MRI. , 2000 .

[34]  S. Reingold,et al.  The Multiple Sclerosis Functional Composite measure (MSFC): an integrated approach to MS clinical outcome assessment , 1999, Multiple sclerosis.

[35]  Alan C. Evans,et al.  Structural maturation of neural pathways in children and adolescents: in vivo study. , 1999, Science.

[36]  O. Karlsen,et al.  Parameter estimation from Rician‐distributed data sets using a maximum likelihood estimator: Application to t1 and perfusion measurements , 1999, Magnetic resonance in medicine.

[37]  E M Haacke,et al.  Accurate determination of spin‐density and T1 in the presence of RF‐field inhomogeneities and flip‐angle miscalibration , 1998, Magnetic resonance in medicine.

[38]  Jullie W Pan,et al.  Quantitative spectroscopic imaging of the human brain , 1998, Magnetic resonance in medicine.

[39]  G. Bruce Pike,et al.  Standing-wave and RF penetration artifacts caused by elliptic geometry: an electrodynamic analysis of MRI , 1998, IEEE Transactions on Medical Imaging.

[40]  A R Tate,et al.  Towards a method for automated classification of 1H MRS spectra from brain tumours , 1998, NMR in biomedicine.

[41]  G J Barker,et al.  Measurement of small inter-scan fluctuations in voxel dimensions in magnetic resonance images using registration. , 1998, Medical physics.

[42]  Alan C. Evans,et al.  A nonparametric method for automatic correction of intensity nonuniformity in MRI data , 1998, IEEE Transactions on Medical Imaging.

[43]  S R Arridge,et al.  A simple method for investigating the effects of non-uniformity of radiofrequency transmission and radiofrequency reception in MRI. , 1998, The British journal of radiology.

[44]  L Fakri-Bouchet,et al.  Measurements of the radiofrequency field in magnetic resonance coils , 1998 .

[45]  J Sijbers,et al.  Estimation of the noise in magnitude MR images. , 1998, Magnetic resonance imaging.

[46]  G. Comi,et al.  Comparison of MRI criteria at first presentation to predict conversion to clinically definite multiple sclerosis. , 1997, Brain : a journal of neurology.

[47]  G H Glover,et al.  An extended two‐point dixon algorithm for calculating separate water, fat, and B0 images , 1997, Magnetic resonance in medicine.

[48]  A. Mackay,et al.  In vivo measurement of T2 distributions and water contents in normal human brain , 1997, Magnetic resonance in medicine.

[49]  S Crozier,et al.  Direct visualisation of B1 inhomogeneity by flip angle dependency. , 1997, Magnetic resonance imaging.

[50]  F Barkhof,et al.  Comparison of four potential MR parameters for severe tissue destruction in multiple sclerosis lesions. , 1997, Magnetic resonance imaging.

[51]  J A Sorenson,et al.  ROC methods for evaluation of fMRI techniques , 1996, Magnetic resonance in medicine.

[52]  A. H. Andersen,et al.  On the Rician distribution of noisy MRI data , 1996, Magnetic resonance in medicine.

[53]  P Wach,et al.  Imaging of the active B1 field in vivo , 1996, Magnetic resonance in medicine.

[54]  P. Tofts Optimal detection of blood-brain barrier defects with Gd-DTPA MRI-the influences of delayed imaging and optimised repetition time. , 1996, Magnetic resonance imaging.

[55]  G. Barker,et al.  An interleaved sequence for accurate and reproducible clinical measurement of magnetization transfer ratio. , 1996, Magnetic resonance imaging.

[56]  H. Gudbjartsson,et al.  The rician distribution of noisy mri data , 1995, Magnetic resonance in medicine.

[57]  M A Moerland,et al.  Analysis and correction of geometric distortions in 1.5 T magnetic resonance images for use in radiotherapy treatment planning. , 1995, Physics in medicine and biology.

[58]  O. Yu,et al.  NMR relaxation rates and blood oxygenation level , 1995, Magnetic resonance in medicine.

[59]  J C Gore,et al.  An roc approach for evaluating functional brain mr imaging and postprocessing protocols , 1995, Magnetic resonance in medicine.

[60]  P. Jezzard,et al.  Correction for geometric distortion in echo planar images from B0 field variations , 1995, Magnetic resonance in medicine.

[61]  D. Altman,et al.  Multiple significance tests: the Bonferroni method. , 1995, BMJ.

[62]  J Hua,et al.  Analysis of on‐ and off‐resonance magnetization transfer techniques , 1995, Journal of magnetic resonance imaging : JMRI.

[63]  G J Barker,et al.  Correction of Nonuniformity in Images of the Spine and Optic Nerve from Fixed Receive‐Only Surface Coils at 1.5 T , 1994, Journal of computer assisted tomography.

[64]  S. Arridge,et al.  Sources of intensity nonuniformity in spin echo images at 1.5 T , 1994, Magnetic resonance in medicine.

[65]  J. Hogg Magnetic resonance imaging. , 1994, Journal of the Royal Naval Medical Service.

[66]  J. Vion-Dury,et al.  A multiparametric data analysis showing the potential of localized proton MR spectroscopy of the brain in the metabolic characterization of neurological diseases , 1993, Journal of Neurological Sciences.

[67]  M. Smith,et al.  An unbiased signal-to-noise ratio measure for magnetic resonance images. , 1993, Medical physics.

[68]  L. Bolinger,et al.  Mapping of the Radiofrequency Field , 1993 .

[69]  M. Zweig,et al.  Receiver-operating characteristic (ROC) plots: a fundamental evaluation tool in clinical medicine. , 1993, Clinical chemistry.

[70]  C. Counsell Stimulated Echoes and Spin Echoes. Simultaneous Determination of T2, Diffusion Coefficient, and RF Homogeneity , 1993 .

[71]  Aaron J. Miller,et al.  The use of power images to perform quantitative analysis on low SNR MR images. , 1993, Magnetic resonance imaging.

[72]  B J Soher,et al.  Quantitation of proton NMR spectra of the human brain using tissue water as an internal concentration reference , 1993, NMR in biomedicine.

[73]  F. Franconi,et al.  Radiofrequency map of an NMR coil by imaging. , 1993, Magnetic resonance imaging.

[74]  G. Barker,et al.  Correction of intensity nonuniformity in MR images of any orientation. , 1993, Magnetic resonance imaging.

[75]  H. Pfeifer Principles of Nuclear Magnetic Resonance Microscopy , 1992 .

[76]  G. Barker,et al.  Semiautomated quality assurance for quantitative magnetic resonance imaging. , 1992, Magnetic resonance imaging.

[77]  Joseph S Gillen,et al.  Experimental determination of three-dimensional RF magnetic field distribution of NMR coils , 1991 .

[78]  G. Barker,et al.  The MRI measurement of NMR and physiological parameters in tissue to study disease process. , 1991, Progress in clinical and biological research.

[79]  J. Pauly,et al.  Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm [NMR imaging]. , 1991, IEEE transactions on medical imaging.

[80]  S K Hilal,et al.  Radio frequency field intensity mapping using a composite spin-echo sequence. , 1990, Magnetic resonance imaging.

[81]  P S Tofts,et al.  Nasal orientation device to control head movement during CT and MR studies. , 1990, Journal of computer assisted tomography.

[82]  M A Bernstein,et al.  A method for correctly setting the rf flip angle , 1989, Magnetic resonance in medicine.

[83]  A simple approach to T2 imaging in MRI. , 1988, Magnetic resonance imaging.

[84]  J. Hornak,et al.  Magnetic field mapping , 1988, Magnetic resonance in medicine.

[85]  Rudolf Stollberger,et al.  RF-field mapping in vivo , 1988 .

[86]  Slice‐shape artifact changes with precession angle in rapid MR imaging , 1987, Magnetic resonance in medicine.

[87]  L. Axel,et al.  Intensity correction in surface-coil MR imaging. , 1987, AJR. American journal of roentgenology.

[88]  M. R. Willcott,et al.  Magnetic field mapping in NMR imaging. , 1987, Magnetic resonance imaging.

[89]  B. Condon,et al.  Image non-uniformity in magnetic resonance imaging: its magnitude and methods for its correction. , 1987, The British journal of radiology.

[90]  W. Edelstein,et al.  The intrinsic signal‐to‐noise ratio in NMR imaging , 1986, Magnetic resonance in medicine.

[91]  R. Henkelman Erratum: Measurement of signal intensities in the presence of noise in MR images [Med. Phys. 12, 232 (1985)] , 1986 .

[92]  R. Henkelman Measurement of signal intensities in the presence of noise in MR images. , 1985, Medical physics.

[93]  M. O’Donnell,et al.  POTENTIAL PROBLEMS WITH SELECTIVE PULSES IN NMR IMAGING SYSTEMS , 1984, Medical physics.

[94]  W. Edelstein,et al.  A signal-to-noise calibration procedure for NMR imaging systems. , 1984, Medical physics.

[95]  D. I. Hoult,et al.  The NMR receiver: A description and analysis of design , 1978 .