In vitro comparison of two different mechanical circulatory support devices installed in series and in parallel.

This study investigates the novel approach of placing a ventricular assist pump in the descending aorta in series configuration with the heart and compares it with the two traditional approaches of left-ventricle-to-ascending-aorta (LV-AA) and left-ventricle-to-descending-aorta (LV-DA) placement in parallel with the heart. Experiments were conducted by using the in-house simulator of the cardiovascular blood-flow loop (SCVL). The results indicate that the use of the LV-AA in-parallel configuration leads to a significant improvement in the systemic and pulmonic flow as the level of continuous flow is increased; however, this approach is considered highly invasive. The use of the LV-DA in-parallel configuration leads to an improvement in the systemic and pulmonic flow at lower levels of continuous flow but at higher levels of pump support leads to retrograde flow. In both in-parallel configurations, increasing the level of pump continuous flow leads to a decrease in pulsatility to a certain extent. The results of placing the pump in the descending aorta in series configuration show that the pressure drop upstream of the pump facilitates cardiac output as a result of afterload reduction. In addition, the pressure rise downstream of the pump may assist with renal perfusion. However, at the same time, the pressure drop generated at the proximal part of the descending aorta induces a slight drop in carotid perfusion, which would be autoregulated by the brain in a native cardiovascular system. The pulse wave analysis shows that placing the pump in the descending aorta leads to improved pulsatility in comparison with the traditional in-parallel configurations.

[1]  G. Giridharan,et al.  Ascending aorta outflow graft location and pulsatile ventricular assist provide optimal hemodynamic support in an adult mock circulation. , 2005, Artificial organs.

[2]  Theodosios Korakianitis,et al.  A concentrated parameter model for the human cardiovascular system including heart valve dynamics and atrioventricular interaction. , 2006, Medical engineering & physics.

[3]  W. Cohn,et al.  A less invasive approach to axial flow pump insertion. , 2008, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[4]  V. Salandin,et al.  Acute renal failure in the patient undergoing cardiac operation. Prevalence, mortality rate, and main risk factors. , 1994, The Journal of thoracic and cardiovascular surgery.

[5]  K. Sun,et al.  The Effects of Pulsatile Flow Upon Renal Tissue Perfusion During Cardiopulmonary Bypass: A Comparative Study of Pulsatile and Nonpulsatile Flow , 2005, ASAIO journal.

[6]  Alain Simon,et al.  Endothelium-dependent arterial wall tone elasticity modulated by blood viscosity. , 2002, American journal of physiology. Heart and circulatory physiology.

[7]  O. Frazier,et al.  Improved left ventricular function after chronic left ventricular unloading. , 1996, The Annals of thoracic surgery.

[8]  R. Hetzer,et al.  Simplified technique for implantation of a left ventricular assist system after previous cardiac operations. , 1999, Annals of Thoracic Surgery.

[9]  R. Autschbach,et al.  Past, Present, and Future of Long‐Term Mechanical Cardiac Support in Adults , 2008, Journal of cardiac surgery.

[10]  D. Mozaffarian,et al.  Heart disease and stroke statistics--2009 update: a report from the American Heart Association Statistics Committee and Stroke Statistics Subcommittee. , 2009, Circulation.

[11]  S. Payne,et al.  Dying trajectories in heart failure , 2007, Palliative medicine.

[12]  L. Gray,et al.  Expanded Pediatric Cardiovascular Simulator for Research and Training , 2010, ASAIO journal.

[13]  A. Guyton,et al.  Textbook of Medical Physiology , 1961 .

[14]  Kozo Hirata,et al.  Age-Related Changes in Carotid Artery Flow and Pressure Pulses: Possible Implications for Cerebral Microvascular Disease , 2006, Stroke.

[15]  J. Sternby,et al.  Hydrodynamic properties of a new percutaneous intra-aortic axial flow pump. , 2000, ASAIO journal.

[16]  Y Sezai,et al.  Major organ function under mechanical support: comparative studies of pulsatile and nonpulsatile circulation. , 1999, Artificial organs.

[17]  Ramakrishna Mukkamala,et al.  Continuous and less invasive central hemodynamic monitoring by blood pressure waveform analysis. , 2010, American journal of physiology. Heart and circulatory physiology.

[18]  C. Selzman,et al.  Off‐Pump Insertion of Continuous Flow Left Ventricular Assist Devices , 2007, Journal of cardiac surgery.

[19]  J. F. Antaki,et al.  Elastance-Based Control of a Mock Circulatory System , 2001, Annals of Biomedical Engineering.

[20]  Akif Undar,et al.  Myths and truths of pulsatile and nonpulsatile perfusion during acute and chronic cardiac support. , 2004, Artificial organs.

[21]  Biswajit Kar,et al.  The effect of LVAD aortic outflow-graft placement on hemodynamics and flow: Implantation technique and computer flow modeling. , 2005, Texas Heart Institute journal.

[22]  T. Korakianitis,et al.  Numerical simulation of cardiovascular dynamics with healthy and diseased heart valves. , 2006, Journal of biomechanics.

[23]  J F Antaki,et al.  HeartMate II left ventricular assist system: from concept to first clinical use. , 2001, The Annals of thoracic surgery.

[24]  T. Korakianitis,et al.  Numerical simulation of cardiovascular dynamics with different types of VAD assistance. , 2007, Journal of biomechanics.

[25]  M. Rothman,et al.  A first‐in‐man study of the reitan catheter pump for circulatory support in patients undergoing high‐risk percutaneous coronary intervention , 2009, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[26]  Theodosios Korakianitis,et al.  Effects of atrial contraction, atrioventricular interaction and heart valve dynamics on human cardiovascular system response. , 2006, Medical engineering & physics.

[27]  D. Mozaffarian,et al.  Heart disease and stroke statistics--2010 update: a report from the American Heart Association. , 2010, Circulation.

[28]  W. Nichols,et al.  Pulse Wave Analysis of the Aortic Pressure Waveform in Severe Left Ventricular Systolic Dysfunction , 2010, Circulation. Heart failure.

[29]  A. Rahmel,et al.  The Registry of the International Society for Heart and Lung Transplantation: twenty-seventh official adult heart transplant report--2010. , 2010, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[30]  A. Hughes,et al.  Reduced systolic wave generation and increased peripheral wave reflection in chronic heart failure. , 2007, American journal of physiology. Heart and circulatory physiology.

[31]  Roland Hetzer,et al.  First experiences with a novel magnetically suspended axial flow left ventricular assist device. , 2004, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[32]  Theodosios Korakianitis,et al.  Numerical simulation of cardiovascular dynamics with left heart failure and in-series pulsatile ventricular assist device. , 2006, Artificial organs.

[33]  Theodosios Korakianitis,et al.  Numerical Comparison of Hemodynamics With Atrium to Aorta and Ventricular Apex to Aorta VAD Support , 2007, ASAIO journal.

[34]  Öyvind Reitan,et al.  Hemodynamic Effects of a New Percutaneous Circulatory Support Device in a Left Ventricular Failure Model , 2003, ASAIO journal.

[35]  R K Jarvik,et al.  Research and development of an implantable, axial-flow left ventricular assist device: the Jarvik 2000 Heart. , 2001, The Annals of thoracic surgery.

[36]  Akbar Rahideh,et al.  In vitro cardiovascular system emulator (bioreactor) for the simulation of normal and diseased conditions with and without mechanical circulatory support. , 2013, Artificial organs.