Impact of scaling and body movement on contaminant transport in airliner cabins

Studies of contaminant transport have been conducted using small-scale models. This investigation used validated Computational Fluid Dynamics (CFD) to examine if a small-scale water model could reveal the same contaminant transport characteristics as a full-scale airliner cabin. But due to similarity problems and the difficulty of scaling the geometry, a perfect scale up from a small water model to an actual air model was found to be impossible. The study also found that the seats and passengers tended to obstruct the lateral transport of the contaminants and confine their spread to the aisle of the cabin. The movement of a crew member or a passenger could carry a contaminant in its wake to as many rows as the crew member or passenger passed. This could be the reason why a SARS infected passenger could infect fellow passengers who were seated seven rows away. To accurately simulate the contaminant transport, the shape of the moving body should be a human-like model.

[1]  R G Sextro,et al.  Pollutant dispersion in a large indoor space: Part 1 -- Scaled experiments using a water-filled model with occupants and furniture. , 2004, Indoor air.

[2]  Qingyan Chen,et al.  Flow and contaminant transport in an airliner cabin induced by a moving body: Model experiments and CFD predictions , 2010 .

[3]  Qingyan Chen,et al.  Influence of cabin conditions on placement and response of contaminant detection sensors in a commercial aircraft. , 2008, Journal of environmental monitoring : JEM.

[4]  H Brohus,et al.  Influence of movements on contaminant transport in an operating room. , 2006, Indoor air.

[5]  Zhiqiang John Zhai,et al.  Evaluation of Various Turbulence Models in Predicting Airflow and Turbulence in Enclosed Environments by CFD: Part 2—Comparison with Experimental Data from Literature , 2007 .

[6]  Zhiqiang Zhai,et al.  Design of a Ventilation System for an Indoor Auto Racing Complex , 2002 .

[7]  Kow-Tong Chen,et al.  Transmission of the severe acute respiratory syndrome on aircraft. , 2003, The New England journal of medicine.

[8]  Qingyan Chen,et al.  Ventilation performance prediction for buildings: A method overview and recent applications , 2009 .

[9]  M. P. Wan,et al.  Modeling the Fate of Expiratory Aerosols and the Associated Infection Risk in an Aircraft Cabin Environment , 2009 .

[10]  Stephane B. Poussou,et al.  Experimental investigation of airborne contaminant transport by a human wake moving in a ventilated aircraft cabin , 2008 .