The hemodynamic effects of compliance, bulging, and curvature in a saphenous vein coronary artery bypass graft model.

The development of Intimal Hyperplasia (IH) in saphenous vein coronary artery bypass grafts (SV-CABG) is responsible for the short-term patency of these grafts. Previous studies of SV-CABG models were performed on rigid anastomotic vessels. However, the effects of compliance, bulging and curvature at the anastomosis on the general hemodynamic field, due to compliance and geometric mismatch between the vein and the artery have not been evaluated. We studied axial and transverse velocities by Laser Doppler Velocimetry on a compliant, in vitro, anatomical model of an end-to-side saphenous vein graft (SVG) to left anterior descending (LAD). The model incorporated a bulge at the sinus and curvature at the graft-host junction. Physiologic pressure and flow conditions pertaining to SV-CABG were applied. The presence of the bulge and curvature showed differences in the velocity profiles in comparison with previous rigid model studies. Dynamic separation zones were temporally augmented at the flow divider. The moving stagnation point at the floor of the host vessel was observed to move past the toe of the model during the accelerating portion of the cycle. These findings suggest that the presence of the bulge curvature and compliance may further favor conditions for the development of intimal hyperplasia (IH) at the floor of a CABG.

[1]  F. Loop,et al.  Surgical treatment of isolated left anterior descending coronary stenosis. Comparison of left internal mammary artery and venous autograft at 18 to 20 years of follow-up. , 1994, The Journal of thoracic and cardiovascular surgery.

[2]  Mechanics of wave reflections in a coronary bypass loop model: the possibility of partial flow cut-off. , 1995, Journal of biomechanics.

[3]  J. Butany,et al.  Histological and morphometric analyses of early and late aortocoronary vein grafts and distal anastomoses. , 1998, The Canadian journal of cardiology.

[4]  B. Lytle,et al.  HDL Cholesterol Level Predicts Survival in Men After Coronary Artery Bypass Graft Surgery: 20-Year Experience From The Cleveland Clinic Foundation , 2000, Circulation.

[5]  C. R. Ethier,et al.  Steady and pulsatile flow fields in an end-to-side arterial anastomosis model. , 1990, Journal of vascular surgery.

[6]  S Glagov,et al.  Measurements of velocity and wall shear stress inside a PTFE vascular graft model under steady flow conditions. , 1997, Journal of biomechanical engineering.

[7]  R. Venugopalan,et al.  Effect of a Flow-Streamlining Implant at the Distal Anastomosis of a Coronary Artery Bypass Graft , 2002, Annals of Biomedical Engineering.

[8]  K. Morinaga,et al.  Effect of wall shear stress on intimal thickening of arterially transplanted autogenous veins in dogs. , 1985, Journal of vascular surgery.

[9]  Thomas E. Moritz,et al.  Predictors of graft patency 3 years after coronary artery bypass graft surgery. Department of Veterans Affairs Cooperative Study Group No. 297. , 1997, Journal of the American College of Cardiology.

[10]  M. Ojha Wall shear stress temporal gradient and anastomotic intimal hyperplasia. , 1994, Circulation research.

[11]  E J Topol,et al.  Aortocoronary saphenous vein graft disease: pathogenesis, predisposition, and prevention. , 1998, Circulation.

[12]  H. Schima,et al.  Numerical study of wall mechanics and fluid dynamics in end-to-side anastomoses and correlation to intimal hyperplasia. , 1996, Journal of biomechanics.

[13]  T. Karino,et al.  Flow patterns and spatial distribution of atherosclerotic lesions in human coronary arteries. , 1990, Circulation research.

[14]  J D Thomas,et al.  The effect of angle and flow rate upon hemodynamics in distal vascular graft anastomoses: a numerical model study. , 1991, Journal of biomechanical engineering.

[15]  D. Steinman,et al.  Effect of distal graft anastomosis site on retrograde perfusion and flow patterns of native coronary vasculature. , 2001, The Annals of thoracic surgery.

[16]  Y. Louagie,et al.  Intraoperative electromagnetic flowmeter measurements in coronary artery bypass grafts. , 1994, The Annals of thoracic surgery.

[17]  P. Davies,et al.  Flow-mediated endothelial mechanotransduction. , 1995, Physiological reviews.

[18]  C. R. Ethier,et al.  Flow waveform effects on end-to-side anastomotic flow patterns. , 1998, Journal of biomechanics.

[19]  C Kleinstreuer,et al.  Numerical investigation and prediction of atherogenic sites in branching arteries. , 1995, Journal of biomechanical engineering.

[20]  J. Copeland,et al.  Starting Aspirin Therapy After Operation: Effects on Early Graft Patency , 1991, Circulation.

[21]  ROBERT M. NEREM,et al.  Velocity Distribution and Intimal Proliferation in Autologous Vein Grafts in Dogs , 1978, Circulation research.

[22]  S Glagov,et al.  Anastomotic intimal hyperplasia: mechanical injury or flow induced. , 1992, Journal of vascular surgery.

[23]  R. Lutz,et al.  Flow instabilities induced by coronary artery stents: assessment with an in vitro pulse duplicator. , 1995, Journal of biomechanics.