Doppler radar noncontact imaging of human cardiac motion

This paper reports recent investigation on the possibility of human cardiac motion imaging using a continuous-wave microwave Doppler radar sensor. Compared with existing works of vital sign radar sensors that mainly focused on the heartbeat rate, the challenge is detect the actual pattern of cardiac motion. To achieve this, a DC-coupled direct conversion architecture and a digital-IF architecture can be used because both of them can avoid frequency-dependent signal distortion. A digital-IF Doppler radar sensor employing an extended differentiate and cross-multiply (DACM) algorithm was adopted to perform a series of experiments that investigate the effectiveness of noncontact cardiac imaging from different orientations of a subject. Experimental results demonstrated that in addition to detecting heartbeat rate, Doppler radar could also image one-dimensional, time domain cardiac motion that fits well with the known physiological description.

[1]  Changzhi Li,et al.  1-D Microwave Imaging of Human Cardiac Motion: An Ab-Initio Investigation , 2013, IEEE Transactions on Microwave Theory and Techniques.

[2]  Changzhi Li,et al.  High Dynamic-Range Motion Imaging Based on Linearized Doppler Radar Sensor , 2014, IEEE Transactions on Microwave Theory and Techniques.

[3]  Jingyu Wang,et al.  Noncontact Distance and Amplitude-Independent Vibration Measurement Based on an Extended DACM Algorithm , 2014, IEEE Transactions on Instrumentation and Measurement.

[4]  Changzhi Li,et al.  Random Body Movement Cancellation in Doppler Radar Vital Sign Detection , 2008, IEEE Transactions on Microwave Theory and Techniques.

[5]  A. Singh,et al.  Respiratory Monitoring and Clutter Rejection Using a CW Doppler Radar With Passive RF Tags , 2012, IEEE Sensors Journal.

[6]  Steve B. Jiang,et al.  Accurate Respiration Measurement Using DC-Coupled Continuous-Wave Radar Sensor for Motion-Adaptive Cancer Radiotherapy , 2012, IEEE Transactions on Biomedical Engineering.

[7]  Jiang Long,et al.  Instrument-Based Noncontact Doppler Radar Vital Sign Detection System Using Heterodyne Digital Quadrature Demodulation Architecture , 2010, IEEE Transactions on Instrumentation and Measurement.

[8]  Changzhan Gu,et al.  Frequency-selective distortion in continuous-wave radar displacement sensor , 2012 .

[9]  J. Lin,et al.  Experiment and Spectral Analysis of a Low-Power $Ka$-Band Heartbeat Detector Measuring From Four Sides of a Human Body , 2006, IEEE Transactions on Microwave Theory and Techniques.

[10]  James C. Lin,et al.  Microwave sensing of physiological movement and volume change: a review. , 1992, Bioelectromagnetics.

[11]  Arye Rosen,et al.  Microwave motion sensing (review of, "microwave noncontact motion sensing and analysis") [book\/software reviews] , 2014, IEEE Microwave Magazine.

[12]  O. Boric-Lubecke,et al.  Dual-Frequency Technique for Assessment of Cardiopulmonary Effective RCS and Displacement , 2012, IEEE Sensors Journal.