Ultra-low-dose protocol for CT-guided lung biopsies.

PURPOSE Computed tomography (CT) scans are a significant source of radiation to patients. It was hypothesized that technical success and complication rates would not be significantly changed by radically lowering the CT dose during lung biopsies with an ultra-low-dose (ULD) protocol. MATERIALS AND METHODS A total of 100 consecutive patients aged 11-89 years who underwent biopsies of lung lesions were evaluated. Technical parameters were altered halfway through the study from the standard dose (140 kV localizing/100 kV subsequent guiding scans with auto-mA) to a ULD protocol (100 kV, 7.5 mAs) as part of a quality initiative. ULD studies were evaluated subjectively for image quality on a five-point scale. Patients' body mass indexes, total estimated radiation doses (dose-length product), technical success rates, and complications were compared between the standard-dose and the ULD groups. RESULTS Average radiation dose was reduced from 677.5 mGy·cm for the standard-dose group to 18.3 mGy·cm for the ULD group (P < .0001). In the ULD group, image quality was rated as adequate or better in 96% of cases. Pneumothoraces necessitating chest tube placements occurred in 10% and 6% of cases in the ULD and standard dose groups, respectively (P = .715). Technical success rates of 92% and 98% were obtained in the ULD and standard dose groups, respectively (P = .362). CONCLUSIONS Radiation dose to the chest during CT-guided percutaneous lung biopsies is reduced greater than 95% versus a standard protocol through the use of a ULD CT protocol without decreasing technical success or patient safety.

[1]  W. Teeuwisse,et al.  Patient and staff dose during CT guided biopsy, drainage and coagulation. , 2001, The British journal of radiology.

[2]  Donald P. Frush,et al.  The ‘Image Gently’ campaign: increasing CT radiation dose awareness through a national education and awareness program , 2008, Pediatric Radiology.

[3]  J. Heldt,et al.  Effect of low dose radiation computerized tomography protocols on distal ureteral calculus detection. , 2009, The Journal of urology.

[4]  K. Takeda,et al.  Optimal scan parameters for CT fluoroscopy in lung interventional radiologic procedures: relationship between radiation dose and image quality. , 2010, Radiology.

[5]  Gabriel Bartal,et al.  Guidelines for patient radiation dose management. , 2009, Journal of vascular and interventional radiology : JVIR.

[6]  Harlan M Krumholz,et al.  Exposure to low-dose ionizing radiation from medical imaging procedures. , 2009, The New England journal of medicine.

[7]  J. Ramírez,et al.  Autologous blood clot seal to prevent pneumothorax at CT-guided lung biopsy. , 2000, Radiology.

[8]  Keith J Strauss,et al.  Image gently: Ten steps you can take to optimize image quality and lower CT dose for pediatric patients. , 2010, AJR. American journal of roentgenology.

[9]  E. Paulson,et al.  CT fluoroscopy--guided interventional procedures: techniques and radiation dose to radiologists. , 2001, Radiology.

[10]  J. Cardella,et al.  Quality improvement guidelines for image-guided percutaneous biopsy in adults. , 2003, Journal of vascular and interventional radiology : JVIR.

[11]  H. Kauczor,et al.  Radiation dose reduction in chest CT: a review. , 2008, AJR. American journal of roentgenology.

[12]  Daniel Y Sze,et al.  CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: needle size and pneumothorax rate. , 2003, Radiology.

[13]  K. Cleary,et al.  Image Guided Interventions. , 2020, Biomedizinische Technik. Biomedical engineering.

[14]  Yun-Chung Cheung,et al.  Risk factors of pneumothorax and bleeding: multivariate analysis of 660 CT-guided coaxial cutting needle lung biopsies. , 2004, Chest.

[15]  L. Tanoue Computed Tomography — An Increasing Source of Radiation Exposure , 2009 .

[16]  Beverley Newman,et al.  Evaluation of a radiation dose reduction strategy for pediatric chest CT. , 2010, AJR. American journal of roentgenology.

[17]  R. Nelson,et al.  Radiation dose for body CT protocols: variability of scanners at one institution. , 2009, AJR. American journal of roentgenology.

[18]  C. McCollough,et al.  How effective is effective dose as a predictor of radiation risk? , 2010, AJR. American journal of roentgenology.

[19]  M. Kalra,et al.  Strategies for CT radiation dose optimization. , 2004, Radiology.

[20]  J. Soto,et al.  CT-guided intervention with low radiation dose: feasibility and experience. , 2007, AJR. American journal of roentgenology.

[21]  T. Nishimura,et al.  Role of manual aspiration in treating pneumothorax after computed tomography-guided lung biopsy , 2009, Acta radiologica.

[22]  Rebecca S Lewis,et al.  Projected cancer risks from computed tomographic scans performed in the United States in 2007. , 2009, Archives of internal medicine.

[23]  K. Chinnaiyan,et al.  Radiation dose from cardiac computed tomography before and after implementation of radiation dose-reduction techniques. , 2009, JAMA.

[24]  K. Strauss,et al.  Image gently, step lightly: increasing radiation dose awareness in pediatric interventions through an international social marketing campaign. , 2009, Journal of vascular and interventional radiology : JVIR.

[25]  Courtney A. Coursey,et al.  CT protocols for acute appendicitis: time for change. , 2009, AJR. American journal of roentgenology.

[26]  E. Moore,et al.  Technical aspects of needle aspiration lung biopsy: a personal perspective. , 1998, Radiology.