Improved equation for estimating single-pool Kt/V at higher dialysis frequencies.

RATIONALE To measure adequacy in patients dialyzed other than three times per week, guidelines recommend the use of 'standard' Kt/V, which commonly is estimated from treatment Kt/V, time and frequency; however, the accuracy of equations that predict treatment Kt/V in patients being dialyzed other than three times per week has not been evaluated. METHODS In patients enrolled in the Frequent Hemodialysis Network (FHN) Daily and Nocturnal Trials who were being dialyzed three, four or six times per week, we tested the accuracy of the following Kt/V prediction equation: Kt/V = -ln(R - GFAC × T_hours) + (4-3.5 × R) × 0.55 × weight loss/V, where R = post-dialysis/pre-dialysis blood urea nitrogen and GFAC, originally set to 0.008 for a 3/week schedule (Daugirdas, J Am Soc Nephrol 1993), is a factor that adjusts for urea generation. RESULTS With the above equation, there was <0.1% mean error in predicted treatment Kt/V for 3/week patients, but mean errors were -5, -9 and -13% for the 6/week daily, 4/week nocturnal and 6/week nocturnal patients. Modeling simulations were performed to optimize the GFAC term for dialysis schedule and length of the preceding interdialysis interval (PIDI). After substituting schedule- and interval-optimized GFAC terms, the treatment Kt/V prediction errors were reduced to -0.81, +0.1 and -1.3% for the three frequent dialysis schedules tested. CONCLUSION For frequent dialysis schedules, the urea generation factor (GFAC) of one commonly used Kt/V prediction equation should be adjusted based on length in days of the PIDI and number of treatments per week.

[1]  John T Daugirdas,et al.  Factors that affect postdialysis rebound in serum urea concentration, including the rate of dialysis: results from the HEMO Study. , 2004, Journal of the American Society of Nephrology : JASN.

[2]  Christopher T. Chan,et al.  The effects of frequent nocturnal home hemodialysis: the Frequent Hemodialysis Network Nocturnal Trial. , 2011, Kidney international.

[3]  W. Couser Pathogenesis of glomerular damage in glomerulonephritis. , 1998, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[4]  Raymond Vanholder,et al.  Section II. Haemodialysis adequacy. , 2002, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[5]  John T Daugirdas,et al.  Standard Kt/Vurea: a method of calculation that includes effects of fluid removal and residual kidney clearance. , 2010, Kidney international.

[6]  T. Depner,et al.  Modeling urea kinetics with two vs. three BUN measurements. A critical comparison. , 1989 .

[7]  R. Stahl,et al.  Cyclooxygenase-2 (COX-2) and the kidney: current status and potential perspectives. , 1998, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[8]  R. Krediet,et al.  Clinical advantages of new peritoneal dialysis solutions. , 2002, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[9]  K. Farrington,et al.  The post-hemodialysis rebound: predicting and quantifying its effect on Kt/V. , 1996, Kidney international.

[10]  J. Leypoldt Urea standard Kt/Vurea for assessing dialysis treatment adequacy , 2004, Hemodialysis international. International Symposium on Home Hemodialysis.

[11]  J. Daugirdas Second generation logarithmic estimates of single-pool variable volume Kt/V: an analysis of error. , 1993, Journal of the American Society of Nephrology : JASN.

[12]  Tom Greene,et al.  Solute-solver: a web-based tool for modeling urea kinetics for a broad range of hemodialysis schedules in multiple patients. , 2009, American journal of kidney diseases : the official journal of the National Kidney Foundation.

[13]  J T Daugirdas,et al.  Overestimation of hemodialysis dose depends on dialysis efficiency by regional blood flow but not by conventional two pool urea kinetic analysis. , 1995, ASAIO journal.

[14]  F. Gotch,et al.  The current place of urea kinetic modelling with respect to different dialysis modalities. , 1998, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[15]  G. Beck,et al.  In-center hemodialysis six times per week versus three times per week. , 2010, The New England journal of medicine.

[16]  T. Depner,et al.  Modeling urea kinetics with two vs. three BUN measurements. A critical comparison. , 1989, ASAIO transactions.