Quantitative evaluation of a comprehensive motion, resolution, and attenuation correction program: Initial experience

BackgroundTomographic myocardial imaging is widely used in the diagnosis and evaluation of patients with coronary artery disease. However, its specificity remains suboptimal because of attenuation, resolution, and motion artifacts. The purpose of this study was to optimize and assess the value of attenuation, blur, and motion correction of myocardial single photon emission computed tomographic data.Methods and ResultsForty-seven studies were selected for analysis to provide 3 patient groups. Group A consisted of 18 patients with a low likelihood of coronary artery disease who were used to construct a quantitative normal database and assess changes in the normal bull’s-eye produced by filtering and by attenuation correction. Group B consisted of 13 patients with a high probability of normal results, and group C consisted of 16 patients with coronary artery disease defined on angiography. The effects of attenuation correction, especially in conjunction with RESTORE (a depth-dependent deblurring filter), have been quantitated. Analysis indicates a trend to improved sensitivity and specificity for detecting individual vessel disease in this retrospective study. The motion correction program was successfully applied to 93% of patients but detected significant motion requiring correction in only 11 (24%) patients.ConclusionThis preliminary retrospective study indicates a potential for improved myocardial single photon emission computed tomography imaging with the use of attenuation and motion correction together with a restorative deblurring filter. Confirmation by a multicenter study and larger patient numbers remain necessary to assess fully the prospective value of the technique.

[1]  M A King,et al.  A Monte Carlo investigation of artifacts caused by liver uptake in single-photon emission computed tomography perfusion imaging with technetium 99m-labeled agents , 1996, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[2]  D. Berman,et al.  Quantitative single photon emission computed thallium-201 tomography for detection and localization of coronary artery disease: optimization and prospective validation of a new technique. , 1989, Journal of the American College of Cardiology.

[3]  A. Jain,et al.  Detection of myocardial ischemia. , 1995, Current problems in cardiology.

[4]  M Schwaiger,et al.  Simultaneous transmission-emission thallium-201 cardiac SPECT: effect of attenuation correction on myocardial tracer distribution. , 1995, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[5]  M. King,et al.  Attenuation compensation for cardiac single-photon emission computed tomographic imaging: Part 1. Impact of attenuation and methods of estimating attenuation maps , 1995, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[6]  J. Fessler,et al.  Simultaneous transmission/emission myocardial perfusion tomography. Diagnostic accuracy of attenuation-corrected 99mTc-sestamibi single-photon emission computed tomography. , 1996, Circulation.

[7]  Matt A. King,et al.  Attenuation compensation for cardiac single-photon emission computed tomographic imaging: Part 2. Attenuation compensation algorithms , 1996, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[8]  D. Bailey,et al.  Improved SPECT using simultaneous emission and transmission tomography. , 1987, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[9]  J M Links,et al.  Wiener filtering improves quantification of regional myocardial perfusion with thallium-201 SPECT. , 1990, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[10]  D. Berman,et al.  Quantitative analysis of tomographic stress thallium-201 myocardial scintigrams: a multicenter trial. , 1990, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[11]  J W Wallis Use of the selective linogram in cardiac tomography quality control , 1995, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[12]  H. Liberman,et al.  Use of cross-correlation function to detect patient motion during SPECT imaging. , 1987, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[13]  Ernest V. Garcia,et al.  Quantitative myocardial perfusion single-photon emission computed tomographic imaging: Quo vadis? (where do we go from here?) , 1994, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[14]  F J Ten Cate,et al.  Prediction of improvement of regional left ventricular function after surgical revascularization. A comparison of low-dose dobutamine echocardiography with 201Tl single-photon emission computed tomography. , 1995, Circulation.

[15]  Lee-Tzuu Chang,et al.  A Method for Attenuation Correction in Radionuclide Computed Tomography , 1978, IEEE Transactions on Nuclear Science.

[16]  B F Hutton,et al.  A scanning line source for simultaneous emission and transmission measurements in SPECT. , 1993, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[17]  L. Becker,et al.  Improved diagnostic performance of exercise thallium-201 single photon emission computed tomography over planar imaging in the diagnosis of coronary artery disease: a receiver operating characteristic analysis. , 1989, Journal of the American College of Cardiology.