Analysis of the Operating Margin Evaluation of Multi-Infeed LCC-HVDC Systems Based on the Equivalent Impedance

In China, a structure in which multiple line-commutated converter based high-voltage direct current (LCC-HVDC) systems feed into the same AC system has been formed. For the multiple LCC-HVDC infeed system, the electrical strength and real operating condition evaluation of the receiving AC system are of great significance for system operation. The multi-infeed short circuit ratio (MISCR) is generally utilized to assess the strength based on the rated parameters; hence, it cannot analyze the real operating condition under the non-rated status. In this paper, an LCC-HVDC system is equivalent to a grounded impedance without changing the external characteristics. The multi-infeed operating short circuit ratio (MIOSCR) is then deduced from the equivalent impedance and equivalent nodal analysis. Relationships between the MIOSCR and electrical strength indices of AC and AC/DC systems are analyzed, and the MISCR is deduced as a special case of the MIOSCR under the rated status. The multi-infeed operating margin coefficient (MIOMC) is finally proposed, which can be utilized to evaluate the operating margin of the LCC-HVDC system and provide guidance for designing operating strategies. The proposed MIOSCR and MIOMC overcome the previous shortcomings of inaccuracy about operating status assessment by the MISCR. The results of the case study demonstrate the effectiveness of the MIOSCR and the MIOMC for assessing the operating condition and margin of converter buses.

[1]  P.F. de Toledo,et al.  Multiple Infeed Short Circuit Ratio – Aspects Related to Multiple HVDC into One AC Network , 2005, 2005 IEEE/PES Transmission & Distribution Conference & Exposition: Asia and Pacific.

[2]  M.J.H. Sterling,et al.  Voltage collapse proximity indicator: behaviour and implications , 1992 .

[3]  Tong Wang,et al.  Principle and Application of Asynchronous Operation of China Southern Power Grid , 2018, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[4]  Yong Tang,et al.  Fast Evaluation of Commutation Failure Risk in Multi-Infeed HVDC Systems , 2018, IEEE Transactions on Power Systems.

[5]  Denis Hau Aik Lee Voltage and power stability of HVDC systems , 1998 .

[6]  Deqiang Gan,et al.  Assessing Strength of Multi-Infeed LCC-HVDC Systems Using Generalized Short-Circuit Ratio , 2019, IEEE Transactions on Power Systems.

[7]  J. Reeve,et al.  Multi-infeed HVDC transient response and recovery strategies , 1993 .

[8]  Hongyang Huang,et al.  Improving Performance of Multi-Infeed HVDC Systems Using Grid Dynamic Segmentation Technique Based on Fault Current Limiters , 2012, IEEE Transactions on Power Systems.

[9]  G. Andersson,et al.  Voltage stability analysis of multi-infeed HVDC systems , 1997 .

[10]  G. Andersson,et al.  Analysis of Voltage and Power Interactions in Multi-Infeed HVDC Systems , 2013, IEEE Transactions on Power Delivery.

[11]  Jun Yang,et al.  An on-line power/voltage stability index for multi-infeed HVDC systems , 2019, Journal of Modern Power Systems and Clean Energy.

[12]  D. J. Morrow,et al.  Online Tracking of Thévenin Equivalent Parameters Using PMU Measurements , 2012, IEEE Transactions on Power Systems.

[13]  Goran Andersson,et al.  An Equivalent Single-Infeed Model of Multi-Infeed HVDC Systems for Voltage and Power Stability Analysis , 2016, IEEE Transactions on Power Delivery.

[14]  Zhen Wang,et al.  Generalized short circuit ratio for multi-infeed LCC-HVDC systems , 2017, 2017 IEEE Power & Energy Society General Meeting.

[15]  G. Andersson,et al.  Use of participation factors in modal voltage stability analysis of multi-infeed HVDC systems , 1998 .

[16]  D. Lee Voltage Stability Assessment Using Equivalent Nodal Analysis , 2016, IEEE Transactions on Power Systems.

[17]  G. Andersson,et al.  Power stability analysis of multi-infeed HVDC systems , 1998 .