Quantification of the Human Cerebrovasculature: A 7Tesla and 320-Row CT In Vivo Study

Objective Human cerebrovasculature has not been quantified in volume, length, and vascular-brain relationships. We investigated this using imaging. Methods From 0.5-mm3 7T and 320-row CT acquisitions, 6 arterial and 4 venous systems were reconstructed, measured, and analyzed. Results The ratio of the volume of arterial to venous system is approximately 1:3. The ratio of the volume of dural sinuses to vasculature is 1:2. The ratio of the posterior (PCA) to anterior (ACA) to middle cerebral artery (MCA) is 1:2:4 in volume and length. Ratios of left to right vessels are 1:1 for arteries and veins. Ratios of branching frequency for the ACA, MCA, and PCA are 1:1:1. The branching frequency ratio for superficial to deep veins is 1:2. The MCA occupies 1/2 of arterial length and 1/4 of vascular length. The ratio of the length of superficial to deep veins is 1:1 and each is equal to 1/4 of the vascular length. The ratio of cerebrovasculature to brain volume is 2.5%. Conclusions Despite its enormous complexity, cerebrovasculature is characterized by 4 approximate proportions, 1:1, 1:2, 1:3, 1:4, and their combinations, 1:1:1 and 1:2:4.

[1]  Brendan J. McCullough The Human Brain in 1492 Pieces: Structure, Vasculature, and Tracts , 2011 .

[2]  Wieslaw Lucjan Nowinski,et al.  Three-dimensional reference and stereotactic atlas of human cerebrovasculature from 7Tesla , 2011, NeuroImage.

[3]  J. Alison Noble,et al.  An adaptive segmentation algorithm for time-of-flight MRA data , 1999, IEEE Transactions on Medical Imaging.

[4]  Ihar Volkau,et al.  Comparison of Magnetic Resonance Angiography Scans on 1.5, 3, and 7 Tesla Units: A Quantitative Study of 3‐Dimensional Cerebrovasculature , 2013, Journal of neuroimaging : official journal of the American Society of Neuroimaging.

[5]  M. Samii,et al.  Skull Base and Related Structures: Atlas of Clinical Anatomy , 1995 .

[6]  Nils Daniel Forkert,et al.  Fuzzy-Based Extraction of Vascular Structures from Time-of-Flight MR Images , 2009, MIE.

[7]  W. L. Nowinski,et al.  The human brain in 1700 pieces: Design and development of a three-dimensional, interactive and reference atlas , 2012, Journal of Neuroscience Methods.

[8]  J. Mocco,et al.  Vasculature of the Brain and Cranial Base: Variations in Clinical Anatomy , 1999 .

[9]  Brian E. Chapman,et al.  Intracranial vessel segmentation from time-of-flight MRA using pre-processing of the MIP Z-buffer: accuracy of the ZBS algorithm , 2004, Medical Image Anal..

[10]  I. Kanno,et al.  Arterial fraction of cerebral blood volume in humans measured by positron emission tomography , 2001, Annals of nuclear medicine.

[11]  Nicolas Passat,et al.  Magnetic resonance angiography: From anatomical knowledge modeling to vessel segmentation , 2006, Medical Image Anal..

[12]  J. O'connell Arteries and Veins of the Human Brain , 1970 .

[13]  Wieslaw Lucjan Nowinski,et al.  A 3D Model of Human Cerebrovasculature Derived from 3T Magnetic Resonance Angiography , 2008, Neuroinformatics.