Analysis on Torsional Stresses in Turbo-Generator Shafts due to Two-Phase Short-Circuit Fault
暂无分享,去创建一个
Taking a 660MW turbine generator shaft system as a target system, the torsional stresses responses are calculated under two-phase short-circuit fault by the finite element (FE) method which can obtain torsional stresses in local areas accurately. The results show that torsional stresses threaten the safety of shafts appear at the first several cycles of the vibration. And the amplitude of stress in weak cross sections located between the low pressure cylinder and the generator is much greater. In addition, the proportion of torsional stresses frequency components in different sections is distinct. The results are helpful to improve the safety management level of the unit.
[1] Tang Gui-ji. Analysis on Response of Shaft Torsional Vibration in Turbine-generator Unit , 2011 .
[2] Yu Jiong Gu,et al. Study on Dynamic Response of Torsional Vibration of Turbo-Generator Unit Caused by Short Circuit Fault , 2012 .
[3] T.-P. Tsao,et al. Torsional fatigue of turbine-generator shafts owing to network faults , 1996 .
[4] Dongxiang Jiang,et al. Torsional vibration and fatigue evaluation in repairing the worn shafting of the steam turbine , 2012 .