Rapid assessment of Escherichia coli by growth rate on piezoelectric-excited millimeter-sized cantilever (PEMC) sensors

Abstract A piezoelectric-excited millimeter sized glass cantilever with a 1 mm 2 sensing surface was fabricated for the purpose of detecting the growth of Escherichia coli ( E. coli ) JM101 in real-time. The resonance characteristic of the fundamental mode in air was 31.08 ± 0.01 kHz. Upon the addition of the agar film to the cantilever sensing surface the fundamental resonance frequency decreased by 2 ± 0.01 kHz. Upon subsequent inoculation of E. coli JM101, the fundamental frequency decreases an additional 0.1 ± 0.01 kHz. The E. coli was grown at 29 °C in a temperature-controlled chamber. The E. coli went through a lag phase of 1 h followed by a continuous decrease in resonant frequency due to growth of the bacteria. The total change in resonant frequency during the growth phase was 5.08 ± 0.01 kHz. After 6 h, the resonant frequency reached a constant value as growth ended. A model was developed to relate resonant frequency to specific growth rate ( μ ). The E. coli exhibited exponential growth rate of 1.31 ± 0.05 h −1 and a late exponential growth rate of 0.55 ± 0.05 h −1 which compared favorably with growth rate obtained in submerged culture of 1.28 ± 0.02 h −1 at 29 °C. The significance of the results is that microbial contamination in food processing plants can be assessed rapidly (

[1]  Martin Hegner,et al.  Micromechanical oscillators as rapid biosensor for the detection of active growth of Escherichia coli. , 2005, Biosensors & bioelectronics.

[2]  David F. Ollis,et al.  Biochemical Engineering Fundamentals , 1976 .

[3]  T. Ross,et al.  Modelling the effects of temperature, water activity, pH and lactic acid concentration on the growth rate of Escherichia coli. , 2003, International journal of food microbiology.

[4]  G. M. Ransom,et al.  Methods Used for Detection and Recovery of Escherichia coli O157:H7 Associated with a Food-Borne Disease Outbreak †. , 1995, Journal of food protection.

[5]  J P Flandrois,et al.  Convenient Model To Describe the Combined Effects of Temperature and pH on Microbial Growth , 1995, Applied and environmental microbiology.

[6]  M. Gomes,et al.  Suitability of PZT ceramics for mass sensors versus widespread used quartz crystals , 2003 .

[7]  L. Nie,et al.  Model of quartz crystal microbe growth sensor and its application to estimation of microbial populations in mineral waters , 1996 .

[8]  T. Naik,et al.  Dynamic response of a cantilever in liquid near a solid wall , 2003 .

[9]  Raj Mutharasan,et al.  Escherichia coli O157:H7 detection limit of millimeter-sized PZT cantilever sensors is 700 cells/mL. , 2005, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[10]  Raj Mutharasan,et al.  Detection and quantification of proteins using self-excited PZT-glass millimeter-sized cantilever. , 2005, Biosensors & bioelectronics.

[11]  P. Hsueh,et al.  Genetic detection of diarrheagenic Escherichia coli isolated from children with sporadic diarrhea. , 2004, Journal of microbiology, immunology, and infection = Wei mian yu gan ran za zhi.

[12]  Fei Liu,et al.  Flexoelectric origin of nanomechanic deflection in DNA-microcantilever system. , 2003, Biosensors & bioelectronics.

[13]  Thomas Thundat,et al.  In situ detection of calcium ions with chemically modified microcantilevers. , 2002, Biosensors & bioelectronics.

[14]  William G Delinger,et al.  Viral detection using an embedded piezoresistive microcantilever sensor , 2003 .

[15]  P. Reichert,et al.  Utility of phenomenological models for describing temperature dependence of bacterial growth , 1991, Applied and environmental microbiology.

[16]  A. Kai,et al.  A new logistic model for Escherichia coli growth at constant and dynamic temperatures , 2004 .

[17]  A. Hortaçsu,et al.  The effect of glucose concentration on the growth rate and some intracellular components of a recombinant E. coli culture , 1995 .

[18]  Raj Mutharasan,et al.  Sensing of liquid level at micron resolution using self-excited millimeter-sized PZT-cantilever , 2005 .

[19]  Ferda Mavituna,et al.  Biochemical engineering and biotechnology handbook , 1982 .

[20]  Robert L. Buchanan,et al.  Response surface models for the growth kinetics of Escherichia coli O157:H7 , 1993 .

[21]  McMeekin,et al.  Applicability of a model for non‐pathogenic Escherichia coli for predicting the growth of pathogenic Escherichia coli , 1998, Journal of applied microbiology.

[22]  J. Corchero,et al.  Control of Escherichia coli growth rate through cell density. , 2002, Microbiological research.

[23]  T. Ross,et al.  Modelling the growth rate of Escherichia coli as a function of pH and lactic acid concentration , 1997, Applied and environmental microbiology.

[24]  Raj Mutharasan,et al.  Detection of pathogen Escherichia coli O157:H7 using self-excited PZT-glass microcantilevers. , 2005, Biosensors & bioelectronics.

[25]  L. Lechuga,et al.  Development of nanomechanical biosensors for detection of the pesticide DDT. , 2003, Biosensors & bioelectronics.

[26]  Raj Mutharasan,et al.  Measuring bacterial growth by tapered fiber and changes in evanescent field. , 2006, Biosensors & bioelectronics.

[27]  Song Zhang,et al.  Zeolite-modified microcantilever gas sensor for indoor air quality control , 2003 .

[28]  F. Elmer,et al.  Eigenfrequencies of a rectangular atomic force microscope cantilever in a medium , 1997 .