Evaluation of challenges and limitations of mechanical thrombectomy using 3D printed neurovascular phantoms

The mechanical thrombectomy (MT) efficacy, for large vessel occlusion (LVO) treatment in patients with stroke, could be improved if better teaching and practicing surgical tools were available. We propose a novel approach that uses 3D printing (3DP) to generate patient anatomical vascular variants for simulation of diverse clinical scenarios of LVO treated with MT. 3DP phantoms were connected to a flow loop with physiologically relevant flow conditions, including input flow rate and fluid temperature. A simulated blood clot was introduced into the model and placed in the Middle Cerebral Artery region. Clot location, composition (hard or soft clot), length, and arterial angulation were varied and MTs were simulated using stent retrievers. Device placement relative to the clot and the outcome of the thrombectomy were recorded for each situation. Angiograms were captured before and after LVO simulation and after the MT. Recanalization outcome was evaluated using the Thrombolysis in Cerebral Infarction (TICI) scale. Forty-two 3DP neurovascular phantom benchtop experiments were performed. Clot mechanical properties, hard versus soft, had the highest impact on the MT outcome, with 18/42 proving to be successful with full or partial clot retrieval. Other factors such as device manufacturer and the tortuosity of the 3DP model correlated weakly with the MT outcome. We demonstrated that 3DP can become a comprehensive tool for teaching and practicing various surgical procedures for MT in LVO patients. This platform can help vascular surgeons understand the endovascular devices limitations and patient vascular geometry challenges, to allow surgical approach optimization.

[1]  C. Ionita,et al.  Comparison of Modern Stroke Thrombectomy Approaches Using an In Vitro Cerebrovascular Occlusion Model , 2015, American Journal of Neuroradiology.

[2]  A. RossNaylor Letter by Naylor Regarding Article, “Guidelines for the Prevention of Stroke in Patients With Stroke or Transient Ischemic Attack: A Guideline for Healthcare Professionals From the American Heart Association/American Stroke Association” , 2011 .

[3]  J. Mocco,et al.  Stent retriever thrombectomy with the Cover accessory device versus proximal protection with a balloon guide catheter: in vitro stroke model comparison , 2015, Journal of NeuroInterventional Surgery.

[4]  Lauren M. Shepard,et al.  Patient-specific 3D-printed coronary models based on coronary computed tomography angiography volumes to investigate flow conditions in coronary artery disease , 2020, Biomedical physics & engineering express.

[5]  Stephen Rudin,et al.  3D printed abdominal aortic aneurysm phantom for image guided surgical planning with a patient specific fenestrated endovascular graft system , 2017, Medical Imaging.

[6]  Stephen Rudin,et al.  Design optimization for accurate flow simulations in 3D printed vascular phantoms derived from computed tomography angiography , 2017, Medical Imaging.

[7]  K. Fargen,et al.  Aspiration thrombectomy versus stent retriever thrombectomy as first-line approach for large vessel occlusion (COMPASS): a multicentre, randomised, open label, blinded outcome, non-inferiority trial , 2019, The Lancet.

[8]  Daniel R. Bednarek,et al.  Treatment planning for image-guided neuro-vascular interventions using patient-specific 3D printed phantoms , 2015, Medical Imaging.

[9]  Lauren M. Shepard,et al.  Initial evaluation of three-dimensionally printed patient-specific coronary phantoms for CT-FFR software validation , 2019, Journal of medical imaging.

[10]  Kelsey N. Sommer,et al.  Method to simulate distal flow resistance in coronary arteries in 3D printed patient specific coronary models , 2020, 3D Printing in Medicine.

[11]  Stephen Rudin,et al.  Challenges and limitations of patient-specific vascular phantom fabrication using 3D Polyjet printing , 2014, Medical Imaging.

[12]  Stephen Rudin,et al.  3D printed cardiac phantom for procedural planning of a transcatheter native mitral valve replacement , 2016, SPIE Medical Imaging.

[13]  Janelle Tabaczynski,et al.  MECHANICAL ASSESSMENT OF 3D PRINTED PATIENT SPECIFIC PHANTOMS FOR SIMULATION OF MINIMALLY INVASIVE IMAGE GUIDED PROCEDURES , 2018 .

[14]  A. Demchuk,et al.  Endovascular thrombectomy after large-vessel ischaemic stroke: a meta-analysis of individual patient data from five randomised trials , 2016, The Lancet.

[15]  M. Wintermark,et al.  Guidelines for the Early Management of Patients With Acute Ischemic Stroke: A Guideline for Healthcare Professionals From the American Heart Association/American Stroke Association , 2013, Stroke.

[16]  Prahlad G. Menon,et al.  Variability of computational fluid dynamics solutions for pressure and flow in a giant aneurysm: the ASME 2012 Summer Bioengineering Conference CFD Challenge. , 2013, Journal of biomechanical engineering.

[17]  C. Ionita,et al.  Assessment of distal access catheter performance during neuroendovascular procedures: measuring force in three-dimensional patient specific phantoms , 2018, Journal of NeuroInterventional Surgery.

[18]  Stephen Rudin,et al.  Primary stentriever versus combined stentriever plus aspiration thrombectomy approaches: in vitro stroke model comparison , 2014, Journal of NeuroInterventional Surgery.

[19]  Daniel R. Bednarek,et al.  Investigation of new flow modifying endovascular image-guided interventional (EIGI) techniques in patient-specific aneurysm phantoms (PSAPs) using optical imaging , 2008, SPIE Medical Imaging.

[20]  Stephen Rudin,et al.  3D printed cardiovascular patient specific phantoms used for clinical validation of a CT-derived FFR diagnostic software , 2018, Medical Imaging.