Purification of plasmid DNA with polymer‐salt aqueous two‐phase system: Optimization using response surface methodology

An experimental design was used to optimize plasmid purification from an alkaline lysate of Escherichia coli cells using PEG‐sodium citrate aqueous two‐phase systems (ATPS), and to evaluate the influence of pH, PEG molecular weight, tie line length, phase volume ratio, and lysate load. To build the mathematical model and minimize the number of experiments for the design parameters, response surface methodology (RMS) with an orthogonal rotatable central composite design was defined based on the conditions found for the highest purification by preliminary tests. The adequacy of the calculated models for the plasmid recovery and remaining RNA were confirmed by means of variance analysis and additional experiments. Analysis of contours of constant response as a function of pH, PEG molecular weight, tie line length, and cell lysate load for three different phase volume ratios revealed different effects of these five factors on the studied parameters. Plasmid recovery of 99% was predicted for a system with PEG 400, pH 6.9, tie line length of 38.7%, phase volume ratio of 1.5, and lysate load of 10% (v/v). Under these conditions the predicted RNA removal was 68%. © 2006 Wiley Periodicals, Inc.

[1]  Rajni Hatti-Kaul,et al.  Aqueous two-phase systems : methods and protocols , 2000 .

[2]  A. Mountain,et al.  Gene therapy: the first decade. , 2000, Trends in biotechnology.

[3]  R. Brown,et al.  Protein measurement using bicinchoninic acid: elimination of interfering substances. , 1989, Analytical biochemistry.

[4]  K. Kimura Simultaneous accumulation of low-molecular-mass RNA at the interface along with accumulation of high-molecular-mass RNA on aqueous two-phase system partitioning. , 2000, Journal of chromatography. B, Biomedical sciences and applications.

[5]  C L Cooney,et al.  Large-scale production of pharmaceutical-grade plasmid DNA for gene therapy: problems and bottlenecks. , 1999, Trends in biotechnology.

[6]  Kenichi Yoshikawa,et al.  Collapse of single DNA molecule in poly(ethylene glycol) solutions , 1995 .

[7]  M. M. Diogo,et al.  Purification of plasmid DNA vectors by aqueous two-phase extraction and hydrophobic interaction chromatography. , 2005, Journal of chromatography. A.

[8]  Ronald G. Crystal,et al.  Transfer of Genes to Humans: Early Lessons and Obstacles to Success , 1995, Science.

[9]  M. Kula,et al.  Extraction of proteins from biological raw material using aqueous polyethylene glycol-citrate phase systems , 1990 .

[10]  C. Kepka,et al.  Extraction of plasmid DNA from Escherichia coli cell lysate in a thermoseparating aqueous two-phase system. , 2004, Journal of chromatography. A.

[11]  Elizabeth A. Schiferl,et al.  Efficiency in Research, Development and Production: The Statistical Design and Analysis of Chemical Experiments , 1993 .

[12]  D. Prazeres,et al.  Isolation of plasmid DNA from cell lysates by aqueous two-phase systems. , 2002, Biotechnology and bioengineering.

[13]  P. Albertsson,et al.  Partition of Cell Particles and Macromolecules , 1986 .

[14]  J. C. Marcos,et al.  Partial purification of penicillin acylase from Escherichia coli in poly(ethylene glycol)-sodium citrate aqueous two-phase systems. , 1999, Journal of chromatography. B, Biomedical sciences and applications.

[15]  M. M. Diogo,et al.  Chromatography of plasmid DNA. , 2005, Journal of chromatography. A.

[16]  K. Kimura,et al.  RNA partitioning accompanied by adsorption: high-molecular-mass RNA adsorbed at the interface like a particle. , 1996, Journal of chromatography. B, Biomedical applications.

[17]  Douglas C. Montgomery,et al.  Response Surface Methodology: Process and Product Optimization Using Designed Experiments , 1995 .

[18]  J. Williams,et al.  A rapid method for the isolation of circular DNA using an aqueous two-phase partition system. , 1978, Nucleic acids research.

[19]  M. Deaton,et al.  Response Surfaces: Designs and Analyses , 1989 .

[20]  M. Eiteman Partitioning of Charged Solutes in Poly(Ethylene Glycol)/Potassium Phosphate Aqueous Two-Phase Systems , 1994 .