Sampled-data based discrete and fast load frequency control for power systems with wind power

Load frequency control employs communication networks to transmit measurements and control signals. The controller is usually designed in continuous-mode and discretized in implementation with a large sampling period, which may result in a degraded dynamic performance or even cause system instability. On the other hand, high penetration of wind power reduces the inertia of the power system, leading to a faster frequency response and larger frequency deviation after a contingency, and desires a fast load frequency control. Therefore, this paper presents a discrete-mode load frequency control scheme considering a large sampling period of control/measurement signals via sampled-data control, and introduces an exponential decay rate as a new performance index to guide a design of load frequency control scheme with desired faster frequency response. The proposed scheme is evaluated on a one-area power system, a traditional two-area power system with wind power and a deregulated three-area power system with wind power. Using the proposed scheme and the state-of-the-art schemes, the frequency response performance and the tolerance to sampling period of power systems are analyzed. The results demonstrate that the proposed control scheme can ensure the stable operation of the system under a larger sampling period so as to reduce the communication network burden. Also, the results show that the controller designed by a large exponential decay rate can provide a fast frequency response to alleviate the impact of the system’s frequency response due to the high penetration of wind power.

[1]  Yang Mi,et al.  Sliding mode load frequency control for multi-area time-delay power system with wind power integration , 2017 .

[2]  Hassan Bevrani,et al.  Robust Power System Frequency Control , 2009 .

[3]  M. A. Abido,et al.  Analysis of Power System Stability Enhancement via Excitation and Facts-Based Stabilizers , 2004 .

[4]  Jinyu Wen,et al.  Chronological operation simulation framework for regional power system under high penetration of renewable energy using meteorological data , 2017 .

[5]  Hongjie Jia,et al.  Coordinated control for EV aggregators and power plants in frequency regulation considering time-varying delays , 2018 .

[6]  Sergio Martinez,et al.  Fast-Frequency Response Provided by DFIG-Wind Turbines and its Impact on the Grid , 2017, IEEE Transactions on Power Systems.

[7]  Lin Jiang,et al.  Robust Load Frequency Control with Dynamic Demand Response for Deregulated Power Systems Considering Communication Delays , 2017 .

[8]  Yong He,et al.  Delay-Dependent Stability Analysis of Multi-Area Load Frequency Control With Enhanced Accuracy and Computation Efficiency , 2019, IEEE Transactions on Power Systems.

[9]  Martin P. Foster,et al.  A Battery Energy Management Strategy for U.K. Enhanced Frequency Response and Triad Avoidance , 2018, IEEE Transactions on Industrial Electronics.

[10]  O. P. Malik,et al.  Discrete analysis of load-frequency control problem , 1984 .

[11]  Alexandre Seuret,et al.  A novel stability analysis of linear systems under asynchronous samplings , 2012, Autom..

[12]  Hassan Bevrani,et al.  Fuzzy Logic-Based Load-Frequency Control Concerning High Penetration of Wind Turbines , 2012, IEEE Systems Journal.

[13]  Pankaj Mukhija,et al.  Design of sampled data and event-triggered load frequency controller for isolated hybrid power system , 2018, International Journal of Electrical Power & Energy Systems.

[14]  Jin Zhang,et al.  Adaptive Event-Triggering ${H}_{\infty }$ Load Frequency Control for Network-Based Power Systems , 2018, IEEE Transactions on Industrial Electronics.

[15]  Yong He,et al.  Further Results on Delay-Dependent Stability of Multi-Area Load Frequency Control , 2013, IEEE Transactions on Power Systems.

[16]  Youyi Wang,et al.  Robust load-frequency controller design for power systems , 1993 .

[17]  H. Shayeghi,et al.  Multi-stage fuzzy PID power system automatic generation controller in deregulated environments , 2006 .

[18]  Takashi Hiyama Optimisation of discrete-type load-frequency regulators considering generation-rate constraints , 1982 .

[19]  Shahzad Ali,et al.  Performance optimization of linear active disturbance rejection control approach by modified bat inspired algorithm for single area load frequency control concerning high wind power penetration. , 2018, ISA transactions.

[20]  Hieu Minh Trinh,et al.  Load Frequency Control of Power Systems With Electric Vehicles and Diverse Transmission Links Using Distributed Functional Observers , 2016, IEEE Transactions on Smart Grid.

[21]  Minrui Fei,et al.  Resilient Event-Triggering $H_{\infty }$ Load Frequency Control for Multi-Area Power Systems With Energy-Limited DoS Attacks , 2017, IEEE Transactions on Power Systems.

[22]  Emilia Fridman,et al.  A refined input delay approach to sampled-data control , 2010, Autom..

[23]  Wen Tan,et al.  Unified Tuning of PID Load Frequency Controller for Power Systems via IMC , 2010, IEEE Transactions on Power Systems.

[24]  Changyin Sun,et al.  An Event-Triggered Approach for Load Frequency Control With Supplementary ADP , 2017, IEEE Transactions on Power Systems.

[25]  Minrui Fei,et al.  Observer based robust integral sliding mode load frequency control for wind power systems , 2017 .

[26]  Yi Zhang,et al.  Coordinated Distributed MPC for Load Frequency Control of Power System With Wind Farms , 2017, IEEE Transactions on Industrial Electronics.

[27]  Zhigang Zeng,et al.  Event-Triggering Load Frequency Control for Multiarea Power Systems With Communication Delays , 2016, IEEE Transactions on Industrial Electronics.

[28]  Hassan Bevrani,et al.  Robust Frequency Control in an Islanded Microgrid: H∞ and μ-Synthesis Approaches , 2016, IEEE Trans. Smart Grid.

[29]  Joydeep Mitra,et al.  An Analysis of the Effects and Dependency of Wind Power Penetration on System Frequency Regulation , 2016, IEEE Transactions on Sustainable Energy.

[30]  P. Kundur,et al.  Power system stability and control , 1994 .

[31]  J. Wen,et al.  Delay-dependent stability for load frequency control with constant and time-varying delays , 2009, 2009 IEEE Power & Energy Society General Meeting.

[32]  Yongduan Song,et al.  Event-Triggered Sliding-Mode Control for Multi-Area Power Systems , 2017, IEEE Transactions on Industrial Electronics.

[33]  M. Azzam,et al.  Robust automatic generation control , 1999 .

[34]  Dong Yue,et al.  Digital PID based load frequency control through open communication networks , 2015, The 27th Chinese Control and Decision Conference (2015 CCDC).

[35]  Kun Liu,et al.  Wirtinger's inequality and Lyapunov-based sampled-data stabilization , 2012, Autom..

[36]  Tapan Kumar Saha,et al.  The combined effects of high penetration of wind and PV on power system frequency response , 2015 .

[37]  Min Wu,et al.  Delay-dependent robust load frequency control for time delay power systems , 2013, 2013 IEEE Power & Energy Society General Meeting.

[38]  Nand Kishor,et al.  A literature survey on load–frequency control for conventional and distribution generation power systems , 2013 .

[39]  Zhan Xu,et al.  Robust analysis and design of load frequency controller for power systems , 2009 .

[40]  Hongxun Hui,et al.  Modeling and control of flexible loads for frequency regulation services considering compensation of communication latency and detection error , 2019, Applied Energy.

[41]  H. Shayeghi,et al.  Robust modified GA based multi-stage fuzzy LFC , 2007 .