Micromachining Technology and Biosensors
暂无分享,去创建一个
I Karube | I. Karube | K. Ikebukuro | Y. Murakami | K. Yokoyama | K Ikebukuro | Y Murakami | K Yokoyama | ISAO KARUBE
[1] Jun Kimura,et al. An integrated SOS/FET multi-biosensor , 1986 .
[2] Willy Sansen,et al. Compensation structures for convex corner micromachining in silicon , 1990 .
[3] I. Karube,et al. Mediated glucose sensor using a cylindrical microelectrode , 1992 .
[4] Isao Karube,et al. Disposable amperometric CO2 sensor employing bacteria and a miniature oxygen electrode , 1991 .
[5] I. Karube,et al. Mediated micro‐glucose sensors using 2 μm platinum electrodes , 1992 .
[6] I. Karube,et al. Integrated biosensor for glucose and galactose , 1989 .
[7] Shuichi Shoji,et al. Micro flow cell for blood gas analysis realizing very small sample volume , 1992 .
[8] D. J. Harrison,et al. Capillary electrophoresis and sample injection systems integrated on a planar glass chip , 1992 .
[9] I. Karube,et al. An integrated multibiosensor for simultaneous amperometric and potentiometric measurement , 1988 .
[10] R. Muller,et al. IC-processed electrostatic micromotors , 1989 .
[11] S. Terry,et al. A gas chromatographic air analyzer fabricated on a silicon wafer , 1979, IEEE Transactions on Electron Devices.
[12] Kenji Yokoyama,et al. Integration of enzyme-immobilized column with electrochemical flow cell using micromachining techniques for a glucose detection system , 1993 .
[13] I. Karube,et al. Development of acetylcholine sensor using carbon fiber (amperometric determination). , 1991, Biosensors & bioelectronics.
[14] I. Karube,et al. Nafion-coated carbon fiber for acetylcholine and choline sensors , 1993 .
[15] Shigeru Nakagawa,et al. Micropump and sample-injector for integrated chemical analyzing systems , 1990 .
[16] I. Karube,et al. Development of a disposable miniature l-lysine sensor , 1990 .
[17] F. Takei,et al. Development of a miniature clark-type oxygen electrode using semiconductor techniques and its improvement for practical applications , 1990 .
[18] I. Karube,et al. Fabrication of an oxygen electrode using semiconductor technology , 1988 .
[19] W. Ko,et al. Compensating corner undercutting in anisotropic etching of (100) silicon , 1989 .
[20] Isao Karube,et al. Ultra micro glutamate sensor using platinized carbon-fiber electrode and integrated counter electrode , 1993 .
[21] Bruno Morten,et al. Piezoresistivity effects in MOS-FET useful for pressure transducers , 1979 .
[22] L.M. Roylance,et al. A batch-fabricated silicon accelerometer , 1979, IEEE Transactions on Electron Devices.
[23] H. Suzuki,et al. A miniature Clark-type oxygen electrode using a polyelectrolyte and its application as a glucose sensor. , 1991, Biosensors & bioelectronics.