Status of VIRGO

The French-Italian interferometric gravitational wave detector VIRGO is currently being commissioned. Its principal instrument is a Michelson interferometer with 3 km long optical cavities in the arms and a power-recycling mirror. This paper gives an overview of the present status of the system. We report on the presently attained sensitivity and the system's performance during the recent commissioning runs. After a sequence of intermediate stages, the interferometer is now being used in the so-called recombined configuration. The input laser beam is spatially filtered by a 144 m long input mode-cleaner before being injected to the main interferometer. The main optics are suspended from so-called \sa s, which provide an excellent seismic isolation. The two 3 km long Fabry-Perot arm cavities are kept in resonance with the laser light, and the Michelson interferometer is held on the dark fringe. An automatic mirror alignment system based on the Anderson technique has been implemented for the arm cavities. The light leaving the dark port contains the gravitational wave signal; this light is filtered by an output mode-cleaner before being detected by a photo detector. This setup is the last step on the way to the final configuration, which will include power recycling.

[1]  John L. Hall,et al.  Laser phase and frequency stabilization using an optical resonator , 1983 .

[2]  D. Babusci,et al.  Alignment procedure for the VIRGO interferometer: experimental results from the Frascati prototype , 1996 .

[3]  Z.Zhang,et al.  Inertial control of the mirror suspensions of the VIRGO interferometer for gravitational wave detection , 2001, gr-qc/0105110.

[4]  W. Kells,et al.  Lock acquisition of a gravitational-wave interferometer. , 2002, Optics letters.

[5]  Koji Arai Sensing and controls for power-recycling of TAMA300 , 2002 .

[6]  Bernard F. Schutz,et al.  The GEO 600 gravitational wave detector , 2002 .

[7]  Daniel Sigg,et al.  Commissioning of the LIGO detectors , 2002 .

[8]  Masaki Ando,et al.  Current status of TAMA , 2002 .

[9]  M. Loupias,et al.  A local control system for the test masses of the Virgo gravitational wave detector , 2004 .

[10]  R. Pound,et al.  Electronic frequency stabilization of microwave oscillators. , 1946, The Review of scientific instruments.

[11]  G. Losurdo,et al.  Measurement of the VIRGO superattenuator performance for seismic noise suppression , 2001 .

[12]  M. Loupias,et al.  First locking of the Virgo central area interferometer with suspension hierarchical control , 2004 .

[13]  G. Russo,et al.  A first study of environmental noise coupling to the Virgo interferometer , 2005 .

[14]  D. Z. Anderson,et al.  Alignment of resonant optical cavities. , 1984, Applied optics.

[15]  Marco Lops,et al.  The VIRGO Project: A wide band antenna for gravitational wave detection , 1990 .

[16]  M. Loupias,et al.  The commissioning of the central interferometer of the Virgo gravitational wave detector , 2004 .