Two-Stage Capture Employing Active Transport Enables Sensitive and Fast Biosensors

Nanoscale sensors enable the detection of analytes with improved signal-to-noise ratio but suffer from mass transport limitations. Molecular shuttles, assembled from, e.g., antibody-functionalized microtubules and kinesin motor proteins, can selectively capture analytes from solution and deliver the analytes to a sensor patch. This two-stage process can accelerate mass transport to nanoscale biosensors and facilitate the rapid detection of analytes. Here, the possible increase of the signal-to-noise ratio is calculated, and the optimal layout of a system which integrates active transport is determined.

[1]  J. Gilman,et al.  Nanotechnology , 2001 .

[2]  H. Berg Random Walks in Biology , 2018 .