The relation between vascular access flow and different types of vascular access with systemic hemodynamics in hemodialysis patients.

Access flow (Qa) has an important effect on systemic hemodynamics in dialysis patients. A Qa : cardiac output (CO) ratio higher than 0.3 is considered a risk factor for high-output cardiac failure. However, the effect of different types of vascular access in hemodialysis patients has not yet been studied. The aim of the present study was to assess the relationship between Qa and systemic hemodynamics and to compare systemic hemodynamics between patients with elbow/upperarm access with forearm access types. Qa, CO, cardiac index (CI), central blood volume (CBV), and peripheral vascular resistance (PVR) were studied by the saline dilution technique in 58 hemodialysis patients (18 with elbow/upperarm access; 40 with forearm access types). This article found that Qa was significantly and positively related to CO and CI, and inversely related to PVR. CBV, Qa, and presence of cardiac failure were independent determinants of CI. Qa and the Qa : CO ratio were significantly higher, and PVR significantly lower, in patients with elbow/upperarm access compared to patients with forearm access types. When patients with cardiac failure were excluded, CO and CI were also significantly higher in patients with elbow/upperarm access types. Eleven percent of patients with elbow/upperarm fistula had a Qa : CO ratio above 0.3. In conclusion, Qa is strongly related to systemic hemodynamics in dialysis patients. In patients without cardiac failure, CO and CI are significantly higher in patients with elbow/upperarm access compared to patients with forearm access types. However, only a small percentage of patients with elbow/upperarm fistulae appeared to be in the risk zone for development of high-output cardiac failure.

[1]  A. Aslam,et al.  Effects of Systemic Hemodynamics on Flow within Vascular Accesses Used for Hemodialysis , 2001, ASAIO journal.

[2]  S. Pandeya,et al.  Arteriovenous fistula-associated high-output cardiac failure: a review of mechanisms. , 2004, American journal of kidney diseases : the official journal of the National Kidney Foundation.

[3]  R. Atkins,et al.  Determinants of native arteriovenous fistula blood flow , 2004, Nephrology.

[4]  M. Zeier,et al.  Do AV Fistulas Contribute to Cardiac Mortality in Hemodialysis Patients? , 2002, Seminars in dialysis.

[5]  H. Harter,et al.  Cardiac failure and upper extremity arteriovenous dialysis fistulas. Case reports and a review of the literature. , 1976, Archives of internal medicine.

[6]  J. Éthier,et al.  Clinical practice guidelines for vascular access. , 2006, American journal of kidney diseases : the official journal of the National Kidney Foundation.

[7]  S. Pandeya,et al.  The relationship between cardiac output and access flow during hemodialysis. , 1999, ASAIO journal.

[8]  N M Krivitski,et al.  Theory and validation of access flow measurement by dilution technique during hemodialysis. , 1995, Kidney international.

[9]  K. Leunissen,et al.  Haemodynamics and electrolyte balance: a comparison between on-line pre-dilution haemofiltration and haemodialysis. , 2004, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[10]  I. Engelberts,et al.  High-output cardiac failure due to excessive shunting in a hemodialysis access fistula: an easily overlooked diagnosis. , 1995, American journal of nephrology.

[11]  T. Depner,et al.  Cardiac output and central blood volume during hemodialysis: methodology. , 1999, Advances in renal replacement therapy.

[12]  B. Murray,et al.  Effect of surgical banding of a high-flow fistula on access flow and cardiac output: intraoperative and long-term measurements. , 2004, American journal of kidney diseases : the official journal of the National Kidney Foundation.