Assessment of an ICA-based noise reduction method for multi-channel auditory evoked potentials

In this work a new independent component analysis (ICA) based method for noise reduction in evoked potentials is evaluated on for auditory late responses (ALR) captured with a 63-channel electroencephalogram (EEG) from 10 normal-hearing subjects. The performance of the new method is compared with a single channel alternative in terms of signal to noise ratio (SNR), the number of channels with an SNR above an empirically derived statistical critical value and an estimate of hearing threshold. The results show that the multichannel signal processing method can significantly enhance the quality of the signal and also detected hearing thresholds significantly lower than with the single channel alternative.

[1]  Lars Kai Hansen,et al.  Model Order Estimation for Independent Component Analysis of Epoched EEG Signals , 2008, BIOSIGNALS.

[2]  Bram Van Dun Improving auditory steady-state response detection using multichannel EEG signal processing (Snellere detectie van auditieve steady-state responsen door meerkanaals EEG-signaalverwerking) , 2008 .

[3]  J. Eggermont,et al.  Auditory Evoked Potentials: Basic Principles and Clinical Application , 2006 .

[4]  Steven A. Hillyard,et al.  Human Auditory Attention: A Central or Peripheral Process? , 1971, Science.

[5]  H. Davis,et al.  Enhancement of Evoked Cortical Potentials in Humans Related to a Task Requiring a Decision , 1964, Science.

[6]  Schuster,et al.  Separation of a mixture of independent signals using time delayed correlations. , 1994, Physical review letters.

[7]  Stanley A. Gelfand,et al.  Hearing: An Introduction to Psychological and Physiological Acoustics, Fourth Edition , 1998 .

[8]  H. Begleiter,et al.  AUDITORY EVOKED RESPONSE COMPARISON DURING COUNTING CLICKS AND READING. , 1965, Electroencephalography and clinical neurophysiology.

[9]  Erkki Oja,et al.  Independent component analysis: algorithms and applications , 2000, Neural Networks.

[10]  Christopher J James,et al.  Independent component analysis for biomedical signals , 2005, Physiological measurement.

[11]  Ikaro Silva Estimation of Postaverage SNR from Evoked Responses Under Nonstationary Noise , 2009, IEEE Transactions on Biomedical Engineering.

[12]  Pierre Comon,et al.  Independent component analysis, A new concept? , 1994, Signal Process..

[13]  G. Dawson A summation technique for the detection of small evoked potentials. , 1954, Electroencephalography and clinical neurophysiology.

[14]  Tzyy-Ping Jung,et al.  Independent Component Analysis of Electroencephalographic Data , 1995, NIPS.