Abstract This paper describes a sequence of experiments on a long-span asymmetric composite cellular beam. This type of beam has become very popular, combining the composite action between the steel and concrete with the increased section depth, compared with more commonly used solid-web I sections. Openings in the steel web also reduce the self-weight and can accommodate the passage of service ducts. Eurocode 4 recommends a high degree of shear connection for asymmetric composite beams despite the practical difficulties in achieving this. Recent research suggests that the required degree of shear connection could be reduced, particularly for beams that are unpropped during construction. However, little test data exists to verify the behaviour of unpropped composite cellular beams. Therefore two series of tests were conducted on a 15.26 m long asymmetric composite cellular beam with regular circular openings and an elongated opening at the mid-span. The degree of shear connection was 36%, less than half of that recommended in Eurocode 4, and the beam was unpropped during construction. The beam was subjected to uniformly distributed loading and shear load during the tests. The end-slip, mid-span vertical deflection, shear connector capacity and strain distribution were examined. The beam failed at an applied uniform load of 17.2 kN/m 2 (3.4 × design working load 5.0 kN/m 2 ). The member withstood an applied shear load that was 45% higher than predicted, and exhibited a Vierendeel mechanism at the elongated opening. Overall, these tests demonstrated the potential of unpropped composite cellular beams with low degrees of shear connection.
[1]
Dennis Lam,et al.
Capacities of headed stud shear connectors in composite steel beams with precast hollowcore slabs.
,
2007
.
[2]
R. Mark Lawson,et al.
Simplified elasto-plastic analysis of composite beams and cellular beams to Eurocode 4
,
2011
.
[3]
Kwok-Fai Chung,et al.
INVESTIGATION ON VIERENDEEL MECHANISM IN STEEL BEAMS WITH CIRCULAR WEB OPENINGS
,
2001
.
[4]
Mark A. Bradford,et al.
Full-scale tests on composite steel–concrete beams with steel trapezoidal decking
,
2009
.
[5]
Mike Banfi.
Slip in Composite Beams using Typical Material Curves and the Effect of Changes in Beam Layout and Loading
,
2006
.
[6]
James B.P. Lim,et al.
Design of composite asymmetric cellular beams and beams with large web openings
,
2006
.
[7]
Mehmet Polat Saka,et al.
Ultimate load carrying capacity of optimally designed steel cellular beams
,
2013
.